Technical description of the burner

4.2

Technical data

Tab. A

(1)

Reference conditions: ambient temperature 20 °C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.

(2)

Pressure at test point 18) (Fig. 7 at page 13) with zero pressure in the combustion chamber and maximum burner output.

(3)

Sound pressure measured in manufacturer’s combustion laboratory, with burner operating on test boiler and at maximum rated
output.

4.3

Packaging - Weight 

Approximate measurements.
• The burners are shipped in cardboard boxes with the maxi-

mum dimensions shown in Tab. B.

• The weight of the burner complete with packaging is indicated

in Tab. B.

Tab. B

MODEL

PRESS GBV

Type

604T50

Power 

(1)

Output 

(1)

kW

Mcal/h

kg/h

178 - 356
153 - 306

15 - 30

Fuel

Gas oil and Blends of gas oil and bio fuel (FAME in accordance with EN 14214) up
to 10%

Gas oil

net calorific value

density
viscosity at 20 °C

kWh/kg

Mcal/kg

kg/dm

3

mm

2

/s max

11.86

10.2 (10.200 kcal/kg)

0.82 - 0.85

6 (1.5 °E - 6 cSt)

Operation

• Intermittent (min. 1 stop in 24 hours).
• Single-stage (all - nothing).

Nozzles

number

1

Standard applications

Boilers: water, steam, diathermic oil

Ambient temperature

°C

0 - 40

Combustion air temperature

°C max

60

Electrical supply

V

Hz

230 ~ +/-10%

50 - single-phase

Electric motor

rpm

kW

V
A

2800

0.25

230

2.3

Motor capacitor

μ

F/V

6.3/450

Ignition transformer

V1 - V2

I1 - I2

230 V - 8 kV

1.8 A - 30 mA

Pump

output (at 12 bar)
pressure range
fuel temperature

kg/h

bar

°C max

65

10 - 18

60

Electrical power consumption

kW max

0.50

Protection level

IP40

A

B

C

kg

mm

695

468

542

36

Fig. 1

D88

Содержание PRESS GBV

Страница 1: ...20033090 1 02 2011 Installation use and maintenance instructions Gas oil burners Single stage operation CODE MODEL TYPE 20032884 PRESS GBV 604T50 GB PRESS GBV...

Страница 2: ......

Страница 3: ...minary checks 14 5 4 Installer Servicer notes for the use of Gas oil with Bio blends up to 10 15 5 5 Operating position 15 5 6 Boiler plate 15 5 7 Blast tube length 16 5 8 Securing the burner to the b...

Страница 4: ...20033090 2 GB Contents 9 Faults Possible causes Solutions 32 9 1 Burner start up cycle diagnostics 33 9 2 Operating fault diagnostics 33 9 3 Control card 34 A Appendix Accessories optional 35...

Страница 5: ...re in compliance with the following Technical Standards EN 267 EN 292 and according to the European Directives MD 2006 42 EC Machine Directive LVD 73 23 EEC 2006 95 EC Low Voltage Directive EMC 89 336...

Страница 6: ...livered to the user by the system manufacturer with the recommendation to keep it in the room where the heat generator is to be installed The instruction manual shows the serial number of the burner t...

Страница 7: ...ump safety value and nozzle The Riello war ranty is dependent upon the use of Riello genuine compo nents including the oil lines being used 3 Riello warranty does not cover defects arising from incorr...

Страница 8: ...pliance applica tion and commissioned checking that all combustion param eters are as recommended in the appliance technical manual Riello recommends that the in line and burner oil pump fil ters are...

Страница 9: ...nd maintenance errors or to improper use 3 3 Basic safety rules Children or inexpert persons must not use the appliance Under no circumstances must the intake grids dissipation grids and ventilation v...

Страница 10: ...ol system FS1 Standard 1 stop every 24 h FS2 Continuous working 1 stop every 72 h Electrical supply of the system 1 230 50 1 230V 50Hz 1 210 60 1 210V 60Hz 1 220 60 1 220V 60Hz 1 200 50 60 1 200V 50 6...

Страница 11: ...604T50 Power 1 Output 1 kW Mcal h kg h 178 356 153 306 15 30 Fuel Gas oil and Blends of gas oil and bio fuel FAME in accordance with EN 14214 up to 10 Gas oil net calorific value density viscosity at...

Страница 12: ...0 kg h delivery line the 0 3 mbar combustion chamber pressure line the combustion chamber maximum pressure curve The work point may be found by plotting a vertical line from the desired delivery and a...

Страница 13: ...5 Multiply H2 by F to obtain the maximum reduced pressure H3 of the firing rate If H3 is greater than H1 as shown in Fig 4 the burner deliver the output required If H3 is lower than H1 the burner s de...

Страница 14: ...ngth 1 m Whenever the burner is operated in a much smaller commercial ly available combustion chamber a preliminary test should be performed kg h B mbar 4 6 5 7 23 21 1 5 5 5 6 1 A mbar kg h C 4 5 22...

Страница 15: ...hotocell for flame presence control 15 Fan rotation direction 16 Indexed selector NOTE If the control box 22 Fig 7 push button lights up it indi cates that the burner is in lock out To reset hold the...

Страница 16: ...and regula tions of the laws in force WARNING The handling operations for the burner can be highly dangerous if not carried out with the great est attention keep any unauthorised people at a distance...

Страница 17: ...flexible oil lines must be suitable for bio fuel use check with Riello if in doubt Riello have carefully chosen the specification of the bio compatible components including the flexible oil lines to p...

Страница 18: ...action of the blast tube 5 8 Securing the burner to the boiler Disassemble the blast tube 6 from the burner by proceeding as follows Remove the screws 2 from the two slide bars 3 Remove the screws 1 t...

Страница 19: ...rner s exact delivery can only be determined by weighing Suck the fuel from a recipient mounted on a weighing machine or attach hoses to the nozzles and weigh the fuel that flows out A liter counter c...

Страница 20: ...tly but not to the maximum torque value provided by the wrench Be careful to avoid damaging the nozzle sealing seat Lastly close the burner by screwing in the two screws 1 Fig 15 WARNING Do not use an...

Страница 21: ...oiler sur faces Use two wrenches to screw in the hoses nip ples one to grip the hose connector and the other to grip the nipple in order to apply the op posite force Fig 16 D413 PUMP WARNING Where gas...

Страница 22: ...the regular flow of fuel and quick checking of the state of the filter The return pipe does not require an on off valve but if the user desires to insert one a lever type valve should be selected whi...

Страница 23: ...n line connector must be plugged This solution is possible only with low pump depression values max 0 2 bar and perfectly sealed piping Key Fig 18 H Pump Foot valve height difference L Piping length v...

Страница 24: ...d NPTF into the cylindrical thread G NOTE The pump is equipped with a bypass that connects return line and the suction line The pump is installed on the burner with the bypass closed by screw 6 Fig 31...

Страница 25: ...time required for this operation depends upon the diameter and length of the suction tubing If the pump fails to prime at the first starting of the burner and the burner locks out wait approx 40 secon...

Страница 26: ...able the control box to perform checks of its own start up efficiency Normally the boiler s thermostat pressure switch ensures the stopping of the burner If this is not the case it is necessary to app...

Страница 27: ...RR F All cables to be connected to the burner terminal strip 6 Fig 7 on page 13 should pass through fairleads 7 Fig 7 on page 13 The fairleads and precut holes can be used in various ways One example...

Страница 28: ...in this phase is the application of a pressure gauge on the apposite pump attachment indicated in Tab F at page 17 7 2 3 Fan gate adjustment The fan gate is set using the indexed selector 1 Fig 27 af...

Страница 29: ...DIN Fig 6 on page 12 emissions of Bachar ach CO2 CO CxHy NOx obtained in laboratory tests with our burners proved to be lower than the limits defined by EC Norms EN 267 under the operating conditions...

Страница 30: ...gnificantly higher than expected and the burner s delivery is correct make sure that the boiler is not dirty that the flue gas duct is not obstructed and that the flue gas stack has been correctly siz...

Страница 31: ...sec The ignition transformer switches off After 39 sec The starting cycle comes to an end 7 9 2 Steady State Operation When the temperature or pressure increases until control device TL opens the bur...

Страница 32: ...ty The vacuum meter is installed upstream from the filter and consequently will not indicate whether the filter is clogged or not Contrarily if the problem lies in the suction line check to make sure...

Страница 33: ...accompanying instructions in order to maintain all the original combustion characteristics in tact especially the flue gas temperature and combustion cham ber pressure Lastly check the condition of t...

Страница 34: ...e Presence of electromagnetic disturbance Use the radio disturbance protection kit The burner goes to lock out right after flame appearance Delayed firing by electrodes or poorly adjusted head Adjust...

Страница 35: ...open gate valve Blast tube length unsuited to boiler Contact boiler manufacturer Sequences Colour code Pre purging Ignition phase Operation flame ok Operating with weak flame signal Electrical supply...

Страница 36: ...re at stack T1 Temperature PV Fan pressure RT Combustion head adjustment RS Fan gate valve adjustment T P Temperature or pressure PC Comb chamber pressure Qs Heat loss at stack BURNER MODEL TYPE CODE...

Страница 37: ...re provided in two versions Code 20034277 without filter Code 20034281 with filter For burner deliveries higher than 80 kg h install two parallel de gassing units Kit for lengthening the combustion he...

Страница 38: ......

Страница 39: ......

Страница 40: ...Subject to modifications RIELLO S p A I 37045 Legnago VR Tel 39 0442 630111 http www rielloburners com...

Отзывы: