GENERAL INFORMATION

 

GENERAL INFORMATION

1.1 

General Safety Information

 

9

This product must be installed by a legally qualified heat-

ing engineer. On completion of the installation, the install-

er must issue the owner with a declaration of conformity 

confirming that the installation has been completed to the 

highest standards in compliance with the instructions pro-

vided by 

R

 in this instruction manual, and that it con-

forms to all applicable laws and standards.

 

9

This product must only be used for the purpose for which it 

is designed and made, as specified by 

R

R

 declines 

all responsibility, contractual or other, for damage to prop-

erty or injury to persons or animals caused by improper in-

stallation, adjustment, maintenance or use.

 

9

The room where the boiler is installed must be proper-

ly ventilated to ensure a sufficient supply of air for correct 

combustion.

 

9

If you notice any water leaks, disconnect the boiler from the 

mains electricity supply and shut off the water supply.

 

9

In case of water leaks disconnect the equipment from the 

power mains, close the water supply and promptly alert 

Technical Assistance Service 

R

 or professionally qualified 

personnel.

 

9

The boiler must be serviced at least once a year. The failure 

to perform annual maintenance work will void the warranty 

of the equipment.

 

9

Periodically check that pressure in the central heating cir-

cuit, when cold, is approximately 1.5 bar and below the 

maximum  limit  specified  for  the  boiler.  If  this  is  not  the 

case, contact the Technical Assistance Service 

R

 or pro-

fessionally qualified personnel.

 

9

If the boiler is not going to be used for an extended peri-

od of time, perform the operations described later in this 

manual.

 

9

This manual is an integral part of the equipment and there-

fore must be stored carefully and must ALWAYS accompany 

the boiler even if it is sold to another Owner or User or trans-

ferred to another plant. If it is damaged or lost, request an-

other copy from your local Technical Assistance Service 

R

.

1.2 

Precautions

The operation of any appliance that uses fuel, electrical power 

and water demands that a number of fundamental safety pre-

cautions be respected:

 

0

Do not allow children or infirm persons to operate the sys-

tem unsupervised.

 

0

It is forbidden to use electrical devices or equipment, such 

as switches, appliances, etc. if there is a smell of gas or un-

burnt products. If so:

 

− Ventilate the room, opening doors and windows

 

− Close the fuel shut-off cock

 

− Ask for the prompt intervention of the Technical Assis-

tance Service

 

0

Do not touch the boiler while barefoot or wet.

 

0

Never pull, disconnect, or twist the electrical cables coming 

from the appliance even if it is disconnected from the mains 

electricity supply.

 

0

Do not obstruct or restrict the vents in the room where the 

boiler is installed. Adequate ventilation is essential for cor-

rect combustion.

 

0

Do not expose the boiler to the elements. It is not designed 

for use outdoors.

 

0

It is prohibited to leave inflammable substances and con-

tainers in the room where the boiler is installed.

 

0

Do not dispose of packaging material into the environment, 

or leave it within the reach of children, since it can become 

a potential hazard. Dispose of packaging material in com-

pliance with applicable legislation.

 

0

It is forbidden to operate the boiler without water.

 

0

The equipment casing must not be removed by people 

without specific qualification and expertise.

Содержание INSIEME EVOe 32 B/110 LN

Страница 1: ...cod 20129536 rev 2 03 2019 INSIEME EVOe 32 B 110 LN EN USER MANUAL ...

Страница 2: ...must be observed to ensure the trouble free installation and efficient functioning of your INSIEME EVOe 32 B 110 LN boiler Please accept our renewed thanks for your purchase Riello S p A CONFORMITY INSIEME EVOe 32 B 110 LN boilers conform to the following di rectives Directive 92 42 EEC on efficiency requirements Electromagnetic Compatibility Directive 2014 30 EU Low Voltage Directive 2014 35 EU E...

Страница 3: ... 6 1 6 Control panel 7 1 7 Menu navigation 9 1 8 Navigation scheme 11 1 9 List of user parameters 12 2 USE 14 2 1 Putting into service 14 2 1 1 Preliminary operations 14 2 1 2 Start up 14 2 1 3 Adjustment of heating setpoint 15 2 1 4 Enable disable the heating function 15 2 1 5 Adjustment of domestic setpoint 15 2 1 6 Enable disable the domestic function 15 2 1 7 Special functions 16 2 1 8 Ignitio...

Страница 4: ...e used for an extended peri od of time perform the operations described later in this manual 9 9This manual is an integral part of the equipment and there fore must be stored carefully and must ALWAYS accompany the boiler even if it is sold to another Owner or User or trans ferred to another plant If it is damaged or lost request an other copy from your local Technical Assistance Service R 1 2 Pre...

Страница 5: ...eds the limit threshold of 3 bar Pressure transducer sends a signal to the electronic reg ulator which views and continually checks the primary circuit pressure to switch on the generator or cause it to stop in case of low pressure Boiler temperature probes delivery and return im mersion probe on the delivery line of the generator is used by the regulator to view and check the delivery wa ter temp...

Страница 6: ...sel 6 Control panel 7 Heating expansion reservoir 8 Burner 9 Boiler drain cock 10 Magnesium anode 11 Storage cylinder inspection flange 12 Storage cylinder flange insulation 13 Storage cylinder drain cock 14 Storage cylinder safety valve 15 Storage cylinder fill cock 16 Storage cylinder with insulation 17 Flame inspection window 18 Boiler body 19 Pump 20 Exhaust flue duct 21 Flue gas box cover 22 ...

Страница 7: ...restoring the operation after a stop due to an anomaly 5 Navigation keys 6 Main switch located on the equipment rear wall Light Guide displaying STATUS DESCRIPTION Green blinking Thermal unit drain cycle and initialization in progress after the power supply reset Steady green Thermal unit on Steady red Thermal unit in alarm mode Red blinking Thermal unit in lock out mode ...

Страница 8: ...ing the Installer menu 4 Icon displayed when the burner of the equipment is on The icon will be marked with a cross in case of Permanent or Temporary error 5 Icon displayed when the climatic mode operation is active Par 2001 1 or 2 6 Celsius Fahrenheit temperature 7 Displays current value 8 Displaying of system pressure or parameter number or external temperature 9 Icon displayed when the circulat...

Страница 9: ...eating setpoint when active available 3 Raise the DHW set point when available 4 Decrease the DHW set point when available 5 ENTER RESET Enters into MENU mode If pressed for more than 5 seconds it resets a permanent error Loc Additional functions Button Function with It accesses enable disable heating function mode It accesses enable disable DHW production function mode 9 9For more information see...

Страница 10: ...is mode keys have the following functions Nr Button Function 1 Exits from the menu and cancels a parameter change 2 Exits from the menu and cancels a parameter change 3 Selects the following menu or increases a certain parameter value 4 Selects the previous menu or decreases a certain parameter value 5 ENTER RESET Enters into the selected menu parameter or confirms the parameter change ...

Страница 11: ...11 GENERAL INFORMATION 1 8 Navigation scheme Modalità visualizzazione base Modalità utente Bar C oppure Example of parameter setting change confirmed change canceled or or or ...

Страница 12: ...rol accessory this parameter can be used to quickly change Zone 3 setpoint This parameter simultaneously modifies the value of Par 2303 See Par 2303 See Par 2303 C 0000 047 Quick adjustment of DHW setpoint with heater See Par 2047 C 0000 048 Quick adjustment of DHW setpoint with instant production See Par 2048 C 0000 201 Stops the venting function 0 No action 1 Stop venting 0 1 0 0000 901 Unit of ...

Страница 13: ...irect Zone Zone 1 climatic curve 10 10 0 C Zone 2 Heating Settings 2000 2203 Zone 2 heating setpoint in 0 and 3 heating modes The thermal unit adjustment determines the boiler setpoint in heating mode using the highest value among the requests of all the active zones Par 1101 1201 1301 If Zone 2 is configured as mixed the value set in parameter 1113 will be used as setpoint BT Par 2221 45 AT Par 2...

Страница 14: ...C close the system load valve 2 1 2 Start up Once you have completed all the checks listed above proceed as follows to start up the boiler for the first time set the main switch of the system to ON and the main switch of the equipment to I Upon switching on the display of the control interface of the device shows the following pages in sequence HEAT Bar Bar C F Psi Psi OUTSIDE Firmware version of ...

Страница 15: ...Increase or decrease the setpoint according to the type of system by using the key of To save the modification made and go back to the initial screen wait for 3 seconds or press the key ENTER RESET Check that the thermal unit starts the ignition phase and that the display shows the icon blinking ambient heating request and the icon The boiler now starts up and the burner remains lit until the temp...

Страница 16: ...t the first start up and at each reset of the power supply When the function is active the message Air is displayed During the venting the circulator is enabled so that the air which may be present inside the system circuit can exit through the automatic drain valve of the device The status of the light guide changes to flashing green Circulator and 3 way valve activation every 24 hours Every 24 h...

Страница 17: ...e Please remember that THE PERSON RESPONSIBLE FOR SYSTEM MAN AGEMENT MUST ENSURE THAT PROFESSIONALLY QUALIFIED HEATING ENGINEERS UNDERTAKE PERIODIC MAINTENANCE AND COMBUSTION EFFICIENCY MEASUREMENTS R s Technical Assistance Service is qualified to satisfy these legal requirements and can also provide useful information on MAINTENANCE PROGRAMMES designed to guarantee Greater safety Compliance with ...

Страница 18: ... from the ambient thermostat is missing Check the temperature set on the am bient thermostat Contact your local Technical Assistance Service Insufficient domestic hot water or water not hot enough Diverter valve or pump faulty Contact your local Technical Assistance Service Domestic setpoint Check the temperature setting Contact your local Technical Assistance Service 3 RECYCLING AND DISPOSAL The ...

Страница 19: ...19 ...

Страница 20: ...llo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice ...