USE
2
USE
2.1
Putting into service
Have the
R
Technical Assistance Service start up your
INSIEME
EVOe 32 B/110 LN
boiler for the first time. Once this has been
done, the boiler can be left to function automatically.
Under certain circumstances, such as after long periods of dis-
use, the user may need to re-start it without involving the Tech-
nical Assistance Service.
2.1.1
Preliminary operations
Perform the following checks before starting up the boiler:
− Check that the fuel shut-off cock and heating system
shut-off cock are open
− the pressure of the hydraulic circuit, with cold water, is
1.5 bar
(value indicated on the first screen of the control
panel display) and the circuit is not vented
− The thermal unit
INSIEME EVOe 32 B/110 LN
is equipped
with a system load valve located inside the thermal unit
Bar
°C
− close the system load valve.
2.1.2
Start-up
Once you have completed all the checks listed above, proceed as
follows to start up the boiler for the first time:
− set the main switch of the system to ON and the main
switch of the equipment to (
I
).
Upon switching on, the display of the control interface of the
device shows the following pages in sequence.
HEAT
Bar
Bar
°C
°F
Psi
Psi
OUTSIDE
Firmware version of the thermal unit interface.
In the example the message indicates a firmware version = 0.
Communication test between interface and regulator.
The message “init” will appear briefly to indicate the beginning
of the communication between the interface and regulator in-
side the thermal unit (*)
Firmware version of the thermal unit regulator.
In the example the message indicates a firmware version = 1.
At first start-up and at every restoration of the power supply the
venting function signalled by the message “Air” activates.
The vent cycle lasts 14 minutes.
°C
(*)
If the communication test fails the message “no COMM”
will appear