13
GENERAL INFORMATION
Menu
Par.
No.
Description
Range
Default set-
ting
UM
1000
1032
Error code
1000
1112
Zone 1 heating setpoint
°C
1000
1113
Zone 2 heating setpoint
°C
1000
1114
Zone 3 heating setpoint
°C
1000
1056
Total hours of operation in heating mode
h x 10
1000
1057
Total hours of operation in domestic mode
h x 10
1000
1058
Total hours of operation
h x 10
1000
1063
Input signal 0-10V
V
Direct Zone / Zone 1 Heating Settings
2000
2103
Direct Zone/Zone 1 setpoint in heating mode Par. 2001= 0 and 3
The thermal unit adjustment determines the boiler setpoint in
heating mode, using the highest value among the requests of
all the active zones (Par. 1101, 1201, 1301)
If Zone 1 is configured as mixed, the value set in parameter 1112
will be used as setpoint
If Zone 1 is not
enabled:
(Par. 2121, Par. 2024)
If Zone 1 is ena-
bled:
BT: (Par. 2121, 45)
AT: (Par. 2121,Par.
2024)
70 (AT)
45 (BT)
°C
2000
2130
Parallel shift of direct Zone/Zone 1 climatic curve
-10…10
0
°C
Zone 2 Heating Settings
2000
2203
Zone 2 heating setpoint in 0 and 3 heating modes
The thermal unit adjustment determines the boiler setpoint in
heating mode, using the highest value among the requests of
all the active zones (Par. 1101, 1201, 1301)
If Zone 2 is configured as mixed, the value set in parameter 1113
will be used as setpoint.
BT: (Par. 2221, 45)
AT: (Par. 2221,Par.
2024)
70 (AT)
45 (BT)
°C
2000
2230
Parallel shift of direct Zone/Zone 1 climatic curve
-10…10
0
°C
Zone 3 Heating Settings
2000
2303
Zone 3 heating setpoint in 0 and 3 heating modes
The thermal unit adjustment determines the boiler setpoint in
heating mode, using the highest value among the requests of
all the active zones (Par. 1101, 1201, 1301)
If Zone 3 is configured as mixed, the value set in parameter 1114
will be used as setpoint.
BT: (Par. 2321, 45)
AT: (Par. 2321,Par.
2024)
70 (AT)
45 (BT)
°C
2000
2330
Parallel shift of direct Zone/Zone 1 climatic curve
-10…10
0
°C
DHW settings and system configuration
2000
2047
DHW setpoint with heater
40...65
57
°C
2000
2048
DHW setpoint with instant production
40…70
45
°C