31
2.2.22
Diagram 22
Management of the area with alternative power source separate from the boiler.
Modulating programmable thermostat/remote control with remote control
via WiFi and ON/OFF programmable thermostat (TA), with remote control via
WiFi.
Multi-zone heating system in modulating thermoregulation mode.
OT: full control of boiler, heating, DHW, alarms and settings.
Thermoregulation for every zone with automatic selection of the maximum
request temperature between the different zones.
Multi-zone heating in ON/OFF mode.
Up to 8 zones
Set parameter 29 of the alternative power source area to OFF.
Set parameter 32 according to zone valve opening time.
There cannot be any RF zone receivers where parameter 32 is a value
other than 0.
OT
SET
PROG
RESET
ESC
MODE
SET
PROG
RESET
ESC
MODE
z. ...
z. ...
TA
TA
WiFi Box
RF
server
internet
WiFi WiFi
RF
RF
RF
SET
PROG
RESET
ESC
MODE
TA
230 V
L
N
Hi, Comfort T100 Hi, Comfort T100 Hi, Comfort T100