Faults - Possible causes - Solutions
Tab. N
The burner continues to repeat the
start-up cycle, without lockout
The gas pressure in the network is near the val-
ue on which the min. gas pressure switch is ad-
justed.
The sudden fall in pressure that follows the
opening of the valve causes the temporary
opening of the pressure switch itself immedi-
ately the valve closes and the burner stops.
The pressure starts to increase again.
The pressure switch closes and repeats the
start up cycle.
The sequence repeats endlessly.
Reduce the cut in pressure of the min. gas
pressure switch. Replace the gas filter car-
tridge
Burner goes into lockout during
operation
Fault on air pressure switch
Replace
Maximum gas pressure switch intervention
Adjust or replace
Lockout when the burner stops
Permanence of the flame in the head of com-
bustion simulation of flame
Eliminate the continuation of the flame or re-
place control box
Firing with pulses
Head badly adjusted
Adjust it properly
Fan air damper badly adjusted. Too much air. Adjust it
Firing output too high
Reduce it
Problem
Possible cause
Recommended remedy