9
OVERALL DIMENSIONS AND WATER FITTINgS
R
7200 Kombi Plus
combination cylinders can also be connected to previously installed hot water sources provided heat output
is suitable and care is taken to ensure correct water flow directions. They can also be easily integrated in
R
solar water heating
systems based on CS 25 R solar collectors with fixing system, water control group, expansion vessel and thermostatic mixer valve.
Water fittings have the following specifications:
F
G
H
I
L
M
N
O
P
Q
RI BT
SB
RC2/R30
RI AT
M-R
MC1
RC1 AT
A
E
D
B
C
RC2
R30
RC1 BT
MI
315
380
105
440
MC2
380
RL
UAC
EAF
VS
MC2
Flow from boiler 2 (Ø 1”1/4 F)
MI
Central heating flow (Ø 1”1/4 F)
RC1 BT
LT return to boiler 1 (Ø 1”1/4 F)
RI BT/SB LT central heating return (Ø 1”1/4
F)/(Inertial storage cylinder drain)
RI AT
HT central heating return (Ø 1”1/4 F)
M
Collector outlet (Ø 1” M)
R
Collector return (Ø 1” M)
MC1
Flow from boiler 1 (Ø 1”1/4 F)
RC1 AT
HT return to boiler 1 (Ø 1”1/4 F)
EAF
Domestic cold water inlet (Ø 1” M)
UAC
Domestic hot water outlet (Ø 1” M)
RL
DHW circulation (Ø 3/4” M)
VS
Vent valve fitting (Ø 1/2” F)
RC2/R30 Return to boiler 2 / 30°C water return
(Ø 1”1/4 F)
DESCRIPTION
7200 Kombi Plus
550
A
413
mm
B
863
mm
C
1163
mm
D
1688
mm
E
2055
mm
F
208
mm
g
413
mm
H
496
mm
I
503
mm
L
863
mm
M
960
mm
N
1073
mm
O
1163
mm
P
1598
mm
Q
1688
mm
9
We recommend that you install isolating valves in the outlet
and return lines.
9
Check the efficiency of the seals when filling/refilling the
buffer tank.