Installation
5.8
Positioning the probe - electrode
Make sure that the plate 3)(Fig. 15) is always inserted in the
flattening of the electrode 1)(Fig. 15).
Rest the probe insulator 4) against the air diffuser 2)(Fig. 15).
Tab. J
5.9
Positioning of the pressure test point (model BS1F only)
If the pressure test point 8)(Fig. 6 on page 13) on the intake
opening gets loose accidentally, we recommend to fix it correctly
as described in Fig. 16.
ATTENTION
Respect the positions shown in Tab. J.
Model
A (mm)
BS1F
17
BS2F
30
BS3F
31
BS4F
31
Fig. 15
D6088
3.5 ±
0.3
A
±
0.3
2
3
4
1
Fig. 16
D4497
View from inside the intake opening
12
0°