![Riello 3761171 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/riello/3761171/3761171_installation-use-and-maintenance-instructions_1460040010.webp)
20140262
8
GB
Technical description of the burner
4.4
Technical data
Tab. C
(1)
Reference conditions: Temperature 20°C - Barometric pressure 1013 mbar – Altitude 0 m above sea level.
(2)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum output. The sound
power is measured with the “Free Field” method, as per EN 15036, and according to an accurate “Accuracy: Category 3” measurement, as
described in EN ISO 3746.
4.5
Electrical data
Tab. D
Tab. E
Model
BS1F
BS2F
BS3F
BS4F
Thermal power
(1)
kW
Mcal/h
16 ÷ 52
13.8 ÷ 44.7
35 ÷ 92
30.1 ÷ 78.2
65 ÷ 197
55.9 ÷ 162.5
110 ÷ 249
94.6 ÷ 215
Fuel
Gas
G20
NCV 8
12 kWh/m
3
– 7,000
10,340 kcal/m
3
Pressure: min. 20 mbar – max. 100 mbar
Operation
Intermittent (FS1)
Use
Boilers: water and diathermic oil
Ambient temperature
°C
0 - 40
Combustion air temperature
°C max
40
Noise levels
(2)
Sound pressure
Sound power
dB(A)
61
72
62
73
66
77
71
82
Weight
kg
10
11
15
16.5
Model
BS1F
BS2F
BS3F
BS4F
Electrical power supply
1
~
220/230V 50 Hz
Fan motor
rpm
Hz
W
A
2860
50
0.09
0.6
2835
50
0.09
0.7
2790
50
0.15
1.6
2740
50
0.25
1.9
Ignition transformer
Primary 230V
Secondary 18 kV / 11 mA
Capacitor
F
4.0
6.3
8.0
Absorbed electric power
kW
0.135
0.155
0.355
0.420
Protection level
IP40
Model
BS1F
BS2F
BS3F
BS4F
Electrical power supply
1
~
220/230V 60 Hz
Fan motor
rpm
Hz
W
A
3320
60
0.09
0.75
3245
60
0.09
0.9
3070
60
0.15
2.2
2845
60
0.25
2.7
Ignition transformer
Primary 230V
Secondary 18 kV / 11 mA
Capacitor
F
4.0
6.3
8.0
Absorbed electric power
kW
0.165
0.20
0.485
0.60
Protection level
IP40
Содержание 3761171
Страница 2: ...Translation of the original instructions Traducci n de las instrucciones originales...
Страница 87: ......