10
PRODUCT IDENTIFICATION
b
If these plates or any other means of clearly identifying the product are defaced, removed or lost, proper installa-
tion and servicing may be rendered difficult.
-
Serial number plate
This is located on the boiler body and speci-
fies the serial number, model, furnace power
and maximum operating pressure.
-
Data plate
This lists the technical specifications and per-
formance of the product.
It comes inside the documentation envelope.
On completion of the installation you MUST
apply it in a clearly visible position at the top
of one of the side panels.
If you damage or lose this label, order a
replacement immediately from
r
’s
Technical Assistance Service.
The boilers are identified by two plates:
2 3
2 7 0 0 0 0 5 8 1
WEEK OF
MANUFACTURE
TECHNICAL SPECIFICATIONS
b
The stack must guarantee the minimum draught specified by applicable technical standards, assuming zero pres-
sure at the connection to the flue gas exhaust.
(*) Flue gas temperature with boiler functioning at 80/60°C and a room temperature of 20-25°C.
RTS 2S
115 150 200 247 319 410 526 736 850 1012 1200 1355 1500 1850
Fuel
Gas / Oil
Rated heat input
minimum
79
124 162 215 266 343 440 564 789 911 1085 1286 1452 1658
kW
maximum
125 163 216 264 341 439 563 787 909 1082 1283 1449 1609 1980
kW
Rated useful heat output
Pn
minimum
74
116 151 201 248 320 411 527 737 851 1013 1201 1356 1501
kW
maximum
115 150 200 247 319 410 526 736 850 1012 1200 1355 1500 1850
kW
Useful efficiency
at min. Pn
93,4 93,4 93,4 93,4 93,4 93,4 93,4 93,4 93,4 93,4 93,4 93,4 93,4 93,4
%
at max. Pn
92,2 92,2 92,7 93,5 93,5 93,5 93,5 93,5 93,5 93,5 93,5 93,5 93,2 93,5
%
Useful efficiency at 30% (Pn Max)
97,2 97,2 97,2 97,2 97,2 97,2 97,2 97,2 97,2 97,2 97,2 97,2 97,2 97,2
%
Constant pressure drop (Pn Max)
< 1,4
< 1,2
< 1,0
%
Flue gas temperature (∆T°)
160÷170 (*)
°C
Flue gas mass flow rate (Pn Max)
0,054 0,071 0,093 0,117 0,152 0,193 0,248 0,34 0,395 0,475 0,547 0,609 0,677 0,857
Kg/s
Furnace pressure
1,2
1,6
1,8
3
2,4
3,7
2,2
4,8
6,8
6,1
9,8
5,1
7
7,2
mbar
Furnace volume
75
121 176 176 240 296 453 613 613 812 812 1065 1065 1297
dm
3
Total volume of flue gas side
112 176 253,5 261,5 357,5 443 682 899 899 1209 1209 1656 1656 2088
dm
3
Surface area for heat exchange
3,77 5,32 7,34 8,16 10,06 12,88 18,58 23,45 23,45 30,6 30,6 40,4 40,4 51,82
m
2
Volumetric heat load (Pn Max)
1663 1345 1226 1501 1422 1481 1242 1284 1483 1333 1581 1361 1511 1527
kW/m
3
Specific heat load (Pn Max)
30,6 28,8 27,4 30,9 32,4 32,5 28,9 31,5 36,3 33,6 39,2 33,6 37,1 35,7
kW/m
2
Maximum operating pressure
6
bar
Maximum admissible temperature
110
°C
Maximum operating temperature
95
°C
Min. admissible water return temperature
55
°C
Pressure drop ∆T 10° C
43
50
90
135 170 260 120
57
98
66
80
118 138 122
mbar
Pressure drop ∆T 20° C
12
10
20
34
40
60
34
16
30
20
28
29
38
35
mbar
Water capacity
176 255 319 309 408 495 655 899 899 1193 1193 1537 1537 2111
l
GENERAL