2445
1
GB
Forced draught gas burner
FS10
CODE
3756432
TYPE
564T30
TECHNICAL FEATURES
For gas family 3 (LPG) ask for separate kit.
◆
CE marking according to Gas Appliance Directive 90/396/EEC; PIN 0063AP6680.
◆
According to directives: EMC 89/336/EEC, Low Voltage 73/23/EEC, Machines 98/37/EEC and
Efficiency 92/42/EEC.
◆
Gas train according to EN 676.
NOTES
– The grommet (5) supplied with the burner, must be fitted to the same side of the gas train.
– After having installed the burner verify the access to the fixing screws of the cover.
If necessary replace them with the fixing screws (6) fig. 1 supplied as equipment.
Thermal output
52 – 116 kW
–
45,000 – 100,000 kcal/h
Gas
(Family 2)
Net heat value
8 – 12 kWh/m
3
–
7,000 – 10,340 kcal/m
3
Pressure
min. 10 mbar
–
max. 40 mbar
Electrical supply
single phase,
230 V
±
10%
~
50Hz
Motor
230 V / 0.7 A
Capacitor
4
µ
F
Ignition transformer
primary 230 V / 1.8 A – secondary 8 kV / 30 mA
Absorbed electrical power
0.13 kW
COUNTRY
FR
GB - IE
IT - AT - GR - DK - SE
NL
DE
LU
GAS CATEGORY
II2Er3P
II2H3P
II2H3B/P
II2L3B/P
II2ELL3B/P
II2E3B/P
1 – Air-damper
2 – Screws for fixing the air-damper
3 – 7 pole socket for electrical supply
and control
4 – 6 pole socket for gas train
5 – Grommet
6 – Screw for fixing the cover
7 – Lock-out lamp and reset button
2
5
1
6
7
D5163
Fig. 1
3
2
4