SP-330, SP-330D, SP-500, SSP-1000 Submersible Sump Pumps
Ridge Tool Company
7
Service And Repair
• Service and repair work on this pump must be per-
formed by qualified repair personnel. Pump should
be taken to a RIDGID Independent Authorized
Service Center or returned to the factory. All
repairs made by Ridge service facilities are war-
ranted against defects in material and workman-
ship.
• When servicing this pump, only identical replace-
ment parts should be used. Failure to follow these
steps may create a risk of flooding, property dam-
age, fatal electrical shock, or other serious injury
and may also void your warranty.
If you have any questions regarding the service or
repair of this machine, call or write to:
Ridge Tool Company
Technical Service Department
400 Clark Street
Elyria, Ohio 44036-2023
E-Mail: [email protected]
For name and address of your nearest Independent
Authorized Service Center, contact the Ridge Tool
Company at http://www.RIDGID.com
For Customer Support, call 1-877-9RIDGID.
Troubleshooting
Let the pump cool for a minimum of two hours before servicing because the pump contains hot oil under
pressure. Disconnect pump from power source before servicing.
TROUBLESHOOTING CHART
Symptom
Possible Cause(s)
Corrective Action
Pump will not start
or run
1. Blown fuse or breaker
2. Low line voltage
3. Worn motor
4. Worn switch
5. Impeller not rotating
6. Float obstruction
1. If blown, replace with proper sized fuse or reset
breaker.
2. If voltage is under 108 volts, check wiring size.
3. Replace motor or pump.
4. Replace switch.
5. If impeller will not turn, remove housing and
remove blockage.
6. Make sure float moves freely up and down.
Pumps start and
stops too often
1. Backflow of water from piping
2. Defective switch
3. Dirty Solid-State Water Sensor
(Model
SSP-1000
only)
1. Install or replace check valve.
2. Replace switch (SP-330, SP-330-D, SP-500
Only).
3. Clean sensor face / see Maintenance steps
Pump will not shut
off or thermal pro-
tector turns off
1. Dirty Solid-State Water Sensor
(Model
SSP-1000
only)
2. Defective switch
3. Obstacle in piping
4. Float obstructed
1. Clean sensor face / see Maintenance steps
2. Replace switch.
3. Remove pump and clean pump and piping.
4. Make sure float moves freely up and down.
Pump operates but
delivers little or not
water
1. Low line voltage
2. Plugged impeller
1. If voltage is under 108 volts, check wiring size.
2. Clean out impeller.
Gurgling sound
from pump at end of
cycle
1. Air injested into pump
2. Time required for pumping is less
than 4 seconds
1. Wipe off surface of sensor (see Figure 4).
2. Additional run time will not damage pump.
Содержание SP-330
Страница 20: ...Pompe de puisard submersible SP 330 SP 330D SP 500 SSP 1000 Ridge Tool Company 18 Notes ...
Страница 30: ...SP 330 SP 330D SP 500 SSP 1000 Submersible Sump Pumps Ridge Tool Company 28 Notas ...
Страница 31: ...SP 330 SP 330D SP 500 SSP 1000 Submersible Sump Pumps Ridge Tool Company 29 Notas ...