12 – English
Inspection Overview
The SeeSnake Compact2 can be used for basic
or advanced pipe inspections. To perform a basic
inspection, connect any SeeSnake monitor to the
Compact2, power on the system, push the push
cable through the pipe, and observe the display. An
advanced inspection requires a SeeSnake digital
reporting monitor and additionally involves captur-
ing media and delivering reports to your customer.
1. Place the Compact2 near the pipe entrance.
Make sure the system is stable and the drum
can spin freely.
2. Connect the system cable to the digital report-
ing monitor.
3. Press the Power key to power on the system.
Alternatively, insert a USB drive into the moni-
tor’s USB port and press the Autolog key to
quick-start the inspection.
4. Release the spring clip and, if desired, install a
pipe guide or camera head guide to keep the
camera centered in the pipe. Make sure the
camera lens is clean.
5. Carefully put the camera into the pipe. Protect
the push cable from sharp edges at the pipe
entrance.
6. Push the camera through the pipe and observe
the display.
7. Advanced Options:
• Set the system zero point, or take a tempo-
rary segment distance measurement.
• Capture media.
• Create on-screen custom overlay.
• Locate an inspection point or path.
• Create and deliver an inspection report to
your customer on a USB drive.
8. When the inspection is complete, retrieve the
camera and secure the spring in the spring clip.
Advanced Options
Both basic and advanced pipe inspections can include
taking pipe segment distance measurements, adjusting
the camera’s LED brightness, or activating the sonde.
Depending on your digital reporting monitor’s features,
you may also want to capture media and create reports.
Note: Refer to your digital reporting monitor manual for
instructions on capturing media and creating reports.
• Press the Brightness key to turn up the brightness
of the camera LEDs so you can see further down
the pipe.
• Capture media of the inspection by pressing the
Video key , Autolog key , or Photo key . If you
are using a CS6Pak, you must insert a USB drive
prior to capturing media.
• Press and hold the Zero key for three seconds
to set the system zero point wherever you want to
begin counting from.
• Use a RIDGID SeekTech locating receiver to locate
a point of interest with the integrated 512 Hz sonde.
• Use a RIDGID SeekTech locating receiver with a
transmitter to find the path of a pipe by line tracing
the push cable.