RIDGID SeekTech ST-33Q Скачать руководство пользователя страница 8

8  -  English

SeekTech

®

  

ST-33Q

4�  Inspect any other equipment being used per its 

instructions to make sure it is in good, usable 
condition� 

5�  If any problems are found, do not use the equipment 

until the problems are corrected� 

Work Area and Equipment Set Up

 

WARNING

Set up the ST‑33Q and work area in accordance with these 

procedures to reduce the risk of injury from electrical 

shock, fire, and other causes and to prevent damage to 

the ST‑33Q.

1�  Check work area for the following:

• 

Adequate lighting�

• 

Flammable liquids, vapors, or dust that may ignite� If 
present, do not work in area until sources have been 
identified and corrected� The ST‑33Q is not explosion 
proof� Electrical connections can cause sparks�

• 

Clear, level, stable dry place for operator� Do not use 
the machine while standing in water� 

• 

Clear path to electrical outlet that does not contain any 
potential sources of damage for the power cord when 
using external power� 

2�  Inspect the line to have a signal applied to it� The 

line must be metal to allow the ST‑33Q to locate 
it� If using the transmitter on insulated conductors, 
ground the target conductor at each end to ensure 
that the signal will be strong enough to locate� The 

ST‑33Q is not designed to provide high voltage 
insulation or protection� Do not use where a danger 
of high voltage contact is present�

3�  Determine the presence of chemicals� If chemicals 

are present, it is important to understand the 
specific safety measures required to work around 
the chemicals� Contact the chemical manufacturer 
for required information�

4�  Determine the correct equipment for the application� 

The ST‑33Q is made to locate conductors 

underground� Inspection and locating equipment 
for other applications can be found in the Ridge 

Tool Catalog or online at www�RIDGID�com or www�

RIDGID�eu�

5�  Make sure all equipment has been properly 

inspected�

6�  Evaluate the work area and determine if any 

barriers are needed to keep bystanders away� 
Bystanders can distract the operator during use� If 
working near traffic, erect cones or other barriers 
to alert drivers�

NOTICE 

Do not place two ST‑33Qs in inductive Mode 

with the power ON within 10 ft [3 m] of each other. The 

inductive output of each ST‑33Q can reinforce the load of 

another ST‑33Q and can possibly damage one or both of 

the units.

Kick Stand Positioning

The kick stand on the back of the ST‑33Q allows the unit 

to be positioned on its back which allows easy viewing 
of the screen and access to the controls� Positioning 
the ST‑33Q on the kick stand also helps place the unit 
in a convenient position for locating when using Direct 

Connect Mode� 

ST‑33Q Magnetic Clips

The ST‑33Q contains advanced connection clips that 

can be attached mechanically or magnetically� The front 
end of the clip includes a scraper tip 

(See Item 1, Figure 

6) 

which can be used to remove rust or paint� Before 

connecting the ST‑33Q leads to a flat, metal surface 
such as a steel junction box or fire hydrant, use the tip 
of the clip to scrape off rust and place the teeth of the 
clip (

See Item 2, Figure 6)

 in contact with the metal� The 

teeth and the finger‑guard 

(See Item 3, Figure 6) 

will 

support the clip and the magnet 

(See Item 4, Figure 6) 

will hold the clip to the metal�

NOTE

The magnetic clips provided with the ST‑33Q 

contain strong magnets. Do not place the clips near data 

storage devices, credit cards, ATM cards, or other 

magnetically encoded data.

3

4

1

2

Figure 6  –  ST‑33Q Magnetic Clip

Содержание SeekTech ST-33Q

Страница 1: ...ars on the nameplate Serial No Operator s Manual WARNING Read this Operator s Manual carefully before using this tool Failure to understand and follow the contents of this manual may result in electri...

Страница 2: ...ork Area and Equipment Set Up Kick Stand Positioning 8 ST 33Q Magnetic Clips 8 Powering the ST 33Q 9 Operating Instructions Powering On the ST 33Q 9 Direct Connect Mode 10 Inductive Clamp Mode 12 Indu...

Страница 3: ...nders away while operating equipment Distractions can cause you to lose control Electrical Safety Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators...

Страница 4: ...fety information that is specific to the ST 33Q Read these precautions carefully before using the ST 33Q to reduce the risk of electrical shock fire or other serious personal injury SAVE ALL WARNINGS...

Страница 5: ...et conductor which eliminates metal to metal contact Inductive The ST 33Q is placed over and in line with a conductor The internal antenna will induce a signal to locate the target conductor In additi...

Страница 6: ...Arrow Key High Voltage Indicator Figure 3 Keypad Icon Legend Table 2 Keypad Icons Icon Name Function Inductive Mode Toggles between Inductive Mode and Direct Connect Mode Up Arrow Key Up Arrow Select...

Страница 7: ...the ST 33Q to external voltages greater than 250 V will damage the unit High Temperature Warning If the internal temperature of the ST 33Q reaches 167 F 67 C or greater a warning will appear on the s...

Страница 8: ...ade to locate conductors underground Inspection and locating equipment for other applications can be found in the Ridge Tool Catalog or online at www RIDGID com or www RIDGID eu 5 Make sure all equipm...

Страница 9: ...rnal 10 28VDC power source with a supply no less than 35 W If using an adapter read and follow the instructions as specified by the manufacturer To prevent electrical shock and damage ensure the exter...

Страница 10: ...locations for the ground spike and the target conductor The ST 33Q leads will extend up to 25 ft 7 6 m The further the leads are extended the more incidental the signal and the further the receiver sh...

Страница 11: ...ic sheathing Selecting a Frequency The following frequencies are available for use on the ST 33Q using Direct Connect Mode 128 Hz 1 kHz 1 024 Hz 8 kHz 8 192 Hz 33 kHz 32 768 Hz 93 kHz 93 623 Hz 262 kH...

Страница 12: ...ceiver are set to the same frequency hold the receiver near the ST 33Q cables and confirm that the signal is being received Inductive Clamp Mode Figure 14 ST 33Q with an Inductive Clamp NOTE Ensure th...

Страница 13: ...an external conductor and the ST 33Q is switched to Inductive Mode a warning will appear and an operator override will be required When using Inductive Mode only 8 kHz and 33 kHz frequencies will be a...

Страница 14: ...within air coupling range of the ST 33Q the receiver will measure this field instead of the target conductor Air coupling may distort readings and misconstrue the location of the target conductor Air...

Страница 15: ...ey is pressed while the LCD Setting option is highlighted in the Tools Menu a diagnostic screen showing the current frequency power level and output voltage will appear after a countdown Press the Mai...

Страница 16: ...een with six digit placeholders will appear See Figure 27 Figure 27 User defined Frequency Screen Use the Frequency Key as a Left Arrow Key to move all the way to the left of the screen to access a dr...

Страница 17: ...has been selected for actual use The Odometer option will also display the total time spent in each mode minimum and maximum voltages encountered and the amount of time spent at various power levels U...

Страница 18: ...he ST 33Q to reduce the risk of electrical shock Do not use liquid or abrasive cleaners on the ST 33Q Clean the ST 33Q with damp cloth Only clean screen with cleaners approved for use on LCD screens D...

Страница 19: ...techservices emerson com or in the U S and Canada call 800 519 3456 Disposal Parts of the unit contain valuable materials that can be recycled There are companies that specialize in recycling that may...

Страница 20: ...the ST 33Q are set to the same frequency for example some receivers will use 93 622 9 Hz or 93 696 Hz instead of 93 kHz Create custom frequencies to exactly match the receiver Ensure the proper functi...

Страница 21: ...1 326 Hz 480 kHz 480 323 Hz McLaughlin 9 5 kHz 9 499 Hz 38 kHz 37 997 Hz Metrotech 982 Hz 982 Hz 9 8 kHz 9 820 Hz 82 kHz 82 488 Hz 83 kHz 83 080 Hz PipeHorn 480 kHz 479 956 Hz 512 Hz 512 Hz 8 kHz 8 19...

Страница 22: ...pas couvertes par cette garantie RIDGE TOOL ne sera tenue responsable d aucuns dommages directs ou indirects L influence de la l gislation locale sur la garantie Puisque certaines l gislations locale...