RP 115 Press Tool
999-995-408.10_REV. A
11
2. Pivot pins and moving points should be
cleaned and lubricated at least once a
month with a lightweight general pur-
pose lubricating oil.
3. Check return springs with each use. Jaws
should open and close freely with only
moderate finger effort required.
Required Maintenance
At RIDGID Authorized
Independent Service Center
After 18,000 cycles, the status light will start
blinking to indicate that it is time for main-
tenance and recalibration. The tool will not
run if it is not serviced within 2,000 more
cycles (20,000 total) after the status light
starts blinking.
Pressing Attachments
1. Inspect the press profile daily
(Figure
13).
If rusty, dirty or if there is evidence of
fitting material building up on the inside
diameter, clean with fine grade Scotch-
Brite
®
(Scotch-Brite
®
is a registered trade-
mark of 3M Company) metal polishing
pads (or equivalent), steel wool or a steel
bristle wire brush.
Do not clean pressing profile with
aggressive abrasive materials or methods,
such as emery cloth, sandpaper, grinding
wheels or rotary files. These methods may
alter critical pressing profile dimensions and
cause improper pressed connections that can
lead to extensive property damage.
Figure 13 – Fitting Material Build-Up Requiring
Jaw Cleaning
NOTICE
Fitting Material
Buildup
PROBLEM
POSSIBLE REASON
SOLUTION
Tool will not turn
ON when trigger/run
switch is pressed.
Attachment is locked
onto fitting.
The pressed connec-
tions produced are not
complete.
Troubleshooting
Battery is completely discharged or
battery has failed.
Battery not properly inserted into
handle of tool.
Press connection was not successfully
completed.
Used wrong jaw for the tube size or
material.
The tool was not square to the tube.
Attachment press contour was not
aligned with the fitting contour.
Tool is in need of repair.
Insert fully charged battery/replace
battery.
Check to assure battery is fully
inserted.
Push pressure release button to
remove jaws from fitting. Inspect and
re-press fitting.
Install the correct attachment.
Redo the press connection with new
fitting and new tube. Make sure that the
tool is square to the tube.
Redo the joint with new tube and new
fitting. Make sure the attachment press
contour is aligned with the fitting con-
tour.
.
See Contact Information
for near-
est RIDGID Authorized Independent
Service center.