background image

RP 115 Press Tool

999-995-408.10_REV. A

9

Figure 9 –  Placing Jaws Around Fitting 

Figure 10 –  Jaws Square to Fitting  

 3.  Confirm jaw is appropriately placed and 

square to fitting. Keep fingers and hands 

away from the jaws to avoid crushing 

injuries in jaws or between jaws and sur-

roundings. 

    Depress the trigger/run switch. The tool 

cycle begins and the rollers contact the 

jaw arms and complete the cycle. Con-

tinue to press the trigger/run switch until 

the ram automatically retracts. Automa- 

tic ram retraction indicates that the tool  

has reached the appropriate force and  

the cycle is complete. This is required to 

ensure the complete connection.

    If tool must be removed before a con-

nection is completed, release the trigger/

run switch, depress the pressure release 

button 

(Figure 1

). Any time release button 

is depressed, press is NOT complete and 

the connection must be pressed again to 

ensure completion. If the tool malfunc-

tions during operation, use this proce-

dure.

fully closed to prevent tool damage during 

use. 

NOTE: Do not operate tool without the attach-

ment in place, this can damage the tool.

Preparing Connection

 These instructions are general- 

ized practices for several types of press 

tool attachments. Always follow the specific 

instructions for the press tool attachment 

being used and the fitting manufacturers’ spe-

cific installation instructions to reduce the risk 

of improper press connections and extensive 

property damage. 

  1.  Prepare the press connection according 

to the fitting manufacturer’s instructions.. 

 2.  With dry hands, insert a fully charged 

battery into tool.

Pressing A Fitting 

  1.  Squeeze jaw arms to open jaws. 

Figure 8 – Opening Jaw

 2.  Place open jaws around fitting 

(Figure 

9)

. Properly align jaw press profile with 

contour of the fitting as specified in Fitting 

Manufacturer’s Installation Instructions. 

Release jaw arms to close jaws around 

fitting. Do not hang jaw set from fitting. 

Tool could unexpectedly drop and cause 

serious injury or death.

NOTICE

FPO

FPO

FPO

Содержание RP 115

Страница 1: ...Installing Attachment 8 Preparing Connection 9 Pressing A Fitting 9 Inspecting The Pressed Connection 10 Work Light Disable Enable 10 Storage 10 Maintenance Instructions Cleaning And Lubrication 10 Pr...

Страница 2: ...P 115 PressTool WARNING Read this Operator s Man ual carefully before using this tool Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious pe...

Страница 3: ...tions illustrations and specifications provided with this power tool Failure to follow all instructions listed below may result in electric shock fire and or serious injury SAVE ALL WARNINGS AND INSTR...

Страница 4: ...g tools sharp and clean Pro perly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control the power tool Keep cord away from heat oil sharp edges or moving...

Страница 5: ...bits etc in accordance with these instructions taking into account the working conditions and the work to be performed Use of the power tool for oper ations different from those intended could result...

Страница 6: ...any other equip ment or material used with this tool Failure to follow all instructions and warn ings may result in property damage and or serious injury RIDGID Contact Information If you have any qu...

Страница 7: ...cked Tool has completed service interval 20 000 cycles and requires service Tool has malfunctioned Remove and reinsert battery If still ON have tool serviced 20 sec 2Hz Figure 5 Tool Status Lights Con...

Страница 8: ...these tools Daily exposure levels for sound and vibration need to be evaluated for each application and appropriate safety measures taken when needed Evaluation of exposure levels should consider the...

Страница 9: ...severe injury or death Discard and replace damaged pressing attach ments Inspect the attachment markings to make sure that it is clearly marked as to the system and size that it is appro priate for Do...

Страница 10: ...mpletion If the tool malfunc tions during operation use this proce dure fully closed to prevent tool damage during use NOTE Do not operate tool without the attach ment in place this can damage the too...

Страница 11: ...sed to make the pressed connection This witness mark is a trade mark of the Ridge Tool Company Ab sence of the witness mark may invalidate the system manufacturer s warranty Figure 12 ProPress Witness...

Страница 12: ...es These methods may alter critical pressing profile dimensions and cause improper pressed connections that can lead to extensive property damage Figure 13 Fitting Material Build Up Requiring Jaw Clea...

Страница 13: ...ops during operation Troubleshooting Cont Fitting material build up in the con toured profile area near jaw tips Excessively worn or damaged jaws Fitting material build up in the con toured profile ar...

Страница 14: ...s no longer usable must be collected separately and disposed of in an environmentally correct manner Clearance Requirements The following figures illustrate the clearance requirements for the jaws and...

Страница 15: ...nment where electromagnetic radiation and electrostatic discharges are present and without causing electromagnetic interference to other equip ment These tools conform to all applica ble EMC standards...

Отзывы: