background image

RP 115 Press Tool

999-995-408.10_REV. A

10

Figure 11 –  Pressing the Fitting 

  4.  Release the trigger/run switch.
  5.  Squeeze jaw arms to open jaws.
 6.  Remove jaw from fitting. Avoid sharp 

edges that may have formed on fitting 

during pressing operation.

  7.  When operation is complete, remove 

battery from tool.

Inspecting The Pressed 

Connection

 

1.  Inspect the pressed fitting for:

 

•   Full insertion of tube into fitting.

 

•   Excessive misalignment of the tubes. 

A slight amount of misalignment at a 

press connection is considered nor-

mal.

 

•   Incorrect attachment alignment with the 

fitting contour. Distorted or deformed fit-

ting.

 

•   Any other issues per the fitting manu-

facturer. This could include the removal 

of a control ring or decal (used to indi-

cate the connection has not yet been 

pressed).

 

   If any issues are found, remove fitting 

and install a new press connection.

 2.  If inspecting ProPress fittings, check and 

confirm the presence of the ProPress wit-

ness mark in one of the hex flats 

(See 

Figure 12)

. This unique mark confirms 

that the proper RIDGID Jaw set, designed 

specifically for the ProPress Fitting 

System was used to make the pressed 

connection. This witness mark is a trade- 

mark of the Ridge Tool Company. Ab- 

sence of the witness mark may invalidate 

the system manufacturer’s warranty.

Figure 12 –  ProPress Witness Mark  

  3.  Test the press connection in accordance 

with connector manufacturer instructions, 

normal practice and applicable codes.

Work Light Disable/Enable

• To disable work light, depress run switch 

and remove battery from tool.

• To enable work light, with the battery 

removed, depress run switch and insert 

battery into tool.

Storage

Remove battery from the press tool. Store 

press tool, attachments and battery in case. 

Avoid storing in extreme heat or cold. The 

tool will not turn ON if the tool is outside the 

specification range.

 Store tool in a dry, secured, 

locked area that is out of reach of children and 

people unfamiliar with the press tool. The tool 

is dangerous in the hands of untrained users.

Maintenance 

Instructions  

 WARNING

Make sure the battery is removed from 

tool before performing maintenance or 

making any adjustment. 
Do not open the tool or battery. 

It contains 

no user-serviceable parts.

Cleaning And Lubrication

 

1.  Wipe the tool clean daily with a clean dry 

cloth.

 

2.  Inspect the attachment mounting pin and 

lubricate the pin with silicone lubricant as 

needed.

WARNING

Witness 

Mark

FPO

Содержание RP 115

Страница 1: ...Installing Attachment 8 Preparing Connection 9 Pressing A Fitting 9 Inspecting The Pressed Connection 10 Work Light Disable Enable 10 Storage 10 Maintenance Instructions Cleaning And Lubrication 10 Pr...

Страница 2: ...P 115 PressTool WARNING Read this Operator s Man ual carefully before using this tool Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious pe...

Страница 3: ...tions illustrations and specifications provided with this power tool Failure to follow all instructions listed below may result in electric shock fire and or serious injury SAVE ALL WARNINGS AND INSTR...

Страница 4: ...g tools sharp and clean Pro perly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control the power tool Keep cord away from heat oil sharp edges or moving...

Страница 5: ...bits etc in accordance with these instructions taking into account the working conditions and the work to be performed Use of the power tool for oper ations different from those intended could result...

Страница 6: ...any other equip ment or material used with this tool Failure to follow all instructions and warn ings may result in property damage and or serious injury RIDGID Contact Information If you have any qu...

Страница 7: ...cked Tool has completed service interval 20 000 cycles and requires service Tool has malfunctioned Remove and reinsert battery If still ON have tool serviced 20 sec 2Hz Figure 5 Tool Status Lights Con...

Страница 8: ...these tools Daily exposure levels for sound and vibration need to be evaluated for each application and appropriate safety measures taken when needed Evaluation of exposure levels should consider the...

Страница 9: ...severe injury or death Discard and replace damaged pressing attach ments Inspect the attachment markings to make sure that it is clearly marked as to the system and size that it is appro priate for Do...

Страница 10: ...mpletion If the tool malfunc tions during operation use this proce dure fully closed to prevent tool damage during use NOTE Do not operate tool without the attach ment in place this can damage the too...

Страница 11: ...sed to make the pressed connection This witness mark is a trade mark of the Ridge Tool Company Ab sence of the witness mark may invalidate the system manufacturer s warranty Figure 12 ProPress Witness...

Страница 12: ...es These methods may alter critical pressing profile dimensions and cause improper pressed connections that can lead to extensive property damage Figure 13 Fitting Material Build Up Requiring Jaw Clea...

Страница 13: ...ops during operation Troubleshooting Cont Fitting material build up in the con toured profile area near jaw tips Excessively worn or damaged jaws Fitting material build up in the con toured profile ar...

Страница 14: ...s no longer usable must be collected separately and disposed of in an environmentally correct manner Clearance Requirements The following figures illustrate the clearance requirements for the jaws and...

Страница 15: ...nment where electromagnetic radiation and electrostatic discharges are present and without causing electromagnetic interference to other equip ment These tools conform to all applica ble EMC standards...

Отзывы: