background image

RE 60 Electrical Tool

27

For EC Countries: Do not dispose of elec-

trical equipment with household waste!
According to the European Guideline 2002/ -

96/ EC for Waste Electrical and Electronic

Equipment and its implementation into nation-

al legislation, electrical equipment that is no

longer usable must be collected separately and disposed

of in an environmentally correct manner.

SYMPTOM

Tool will not turn ON

when ON/OFF button  is

pressed.

Tool will not run when

trigger is depressed.

Green light flashes.

Tool turns OFF either

when trigger is

depressed or in the 

middle of a cycle. Red

LED glows.

Yellow LED blinks repeat-

edly as long as tool is

turned ON and tool func-

tions properly.

Yellow LED glows  con-

tinuously and tool will

not begin press cycle

when trigger switch is

depressed.

Yellow LED glows when

tool is turned ON.

The connections 

produced are not 

complete.

Troubleshooting

Battery is completely discharged or battery has

failed.
Battery not properly inserted into handle of tool.

Battery charge is too low.

Tool or battery is too cold or too hot.

Scheduled maintenance/recalibration is required

after 30,000 cycles.

Scheduled maintenance/recalibration is mandato-

ry after 32,000 cycles. Tool is “locked” and will not

function until serviced..

Tool malfunction detected. 

Used wrong interchangeable head/insert for the

cable size or material.

The tool was not square to the connector.

Tool is in need of repair.

Insert fully charged battery/recharge battery.

Check to assure battery is fully inserted.

Insert fully charged battery/recharge battery.

Bring tool and battery to correct operating range

between 23 °F (-5 °C) and 122 °F (50 °C) by allow-

ing the tool to sit in a conditioned room

Contact RIDGID Technical Service Department at

(800) 519-3456 for nearest Authorized Service

center.

Contact RIDGID Technical Service Department at

(800) 519-3456 for nearest Authorizedl Service

center.

Remove and reinsert fully charged battery. Be sure

to repress fitting. If LED continues to glow,Contact

RIDGID Technical Service Department at (800)

519-3456 for nearest Authorized Service center.

Install the correct interchangeable head/insert .

Redo the joint. Make sure that the tool is square

to the connector.
Contact RIDGID Technical Service Department at 

(800) 519-3456  for  nearest  Authorized  Service

center.

POSSIBLE REASONS

SOLUTION

RE 60 Electrical Tool

SYMPTOM

POSSIBLE REASONS

SOLUTION

28

RE 60 Diagnostic Codes

n

o

c

I

Description

Status

LED

Green

Glows

Tool is ON.

Blinks

Battery needs charging..

Red

Glows

Out of temperature range  -10 °C to +50 °C.

Yellow

Blinks

Service indicator after 30,000 cycles. NOTE: Tool will lock after 32,000 cycles.

Glows

Machine is locked – Service after 32,000 cycles or after a tool malfunction.

Figure 7 – LED Diagnostic Codes

Oil leaks from tool.

Motor runs but tool will

not complete a cycle.

Dies stop during opera-

tion.

Troubleshooting

 

(Continued) 

Seal or mechanical problems.

Oil level low.

Oil level low.

partment at

Contact RIDGID Technical Service De 

(800) 519-3456  for  nearest  Authorized  Service

center.

partment at

Contact RIDGID Technical Service De 

(800) 519-3456  for  nearest  Authorized  Service

center.

Contact RIDGID Technical Service De partment at

(800) 519-3456  for  nearest  Authorized  Service

center.

Содержание RE 60

Страница 1: ...warranty on behalf of Emerson Professional Tools Shanghai Co Ltd Emerson Professional Tools Shanghai Co Ltd has the right for final explanation of the above warranty terms Customers are entitled to t...

Страница 2: ...ii 1 2 2 2 3 3 3 3 4 4 5 5 EMC 5 6 6 8 RIDGID 8 8 8 8 8 9 RE 60 10 RE 60 RE 60 RE 60 RIDGID...

Страница 3: ...RE 60 3 GFCI GFCI UL CSA 60745 NOTICE DANGER WARNING CAUTION RE 60 4...

Страница 4: ...0 RIDGID QCS 360 2 LED LED RIDGID QCS RIDGID 5 RE 60 RE 60 2 LED RE 60 RE 60 13 500 lbf 60kN 0 94 24mm 18 V 18 A 324 W 18 V 15 F 122 F 10 C 50 C 92 dB 59 in s2 1 5 m s2 5 lb 2 27 kg 4 04 10 3 EMC 6 RI...

Страница 5: ...RE 60 1 2 QCS 3 QCS QCS 12 4 QCS 4 QCS 4 QCS QCS 5 5 QCS 7 RE 60 8 6 6 LED LED 7 150 7 8 1 2 RIDGID RIDGID www RIDGID com cn RIDGID 400 820 5695400 820 5695 3 4 5 QCS QCS QCS...

Страница 6: ...RIDGID 1 RIDGID QCS QCS 3 30 000 LED 2000 32000 15 F 10 C 122 F 50 C LED RIDGID RE60 RE60 RIDGID www RIDGID com cn Ridge RIDGID 400 820 5695 400 820 5695 QCS 2 RE 60 10 EC ON OFF 30000 32000 23 F 5 C...

Страница 7: ...0 820 5695 RIDGID 400 820 5695 LR 60 12 RIDGID LR 60 RIDGID RE60 RIDGID RIDGID www RIDGID com cn Ridge Ridgid China emerson com RIDGID 400 820 5695 RIDGID 60 RIDGID RE60 RIDGID QCS 360 LR 60 60kN LR 6...

Страница 8: ...DGID RIDGID www RIDGID com cn Ridge Ridgid China emerson com RIDGID 400 820 5695 1 SC 60 400 mm2 B 50 mm 60 kN 13500 lbf RE 60 IB 2 2 kg 1 QCS 2 QCS 3 QCS 4 5 QCS 1 2 2 3 QCS QCS QCS QCS RIDGID SC 60...

Страница 9: ...www RIDGID com cn Ridge Ridgid China emerson com RIDGID 400 820 5695 RIDGID PH 60 3 4 10UNC RIDGID RE60 RIDGID QCS 360 0 135 3 4 mm 0 06 1 5 mm 63 5 mm 3 4 60 kN 1 5 kg 1 QCS 2 QCS 3 QCS 4 5 QCS 1 2 3...

Страница 10: ...Tool Safety 4 Description Specifications And Standard Equipment Description 4 Specifications 5 Standard Equipment 5 Electromagnetic Compatibility EMC 5 Tool Inspection 6 Set Up And Operating Instruct...

Страница 11: ...tension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is un avoidable use a ground fault circuit...

Страница 12: ...mmon sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating power tools may result...

Страница 13: ...ses and prevent tool damage 1 Make sure that the electric tool battery is removed Inspect the battery for damage If any damage or modifications are found do not use until the battery has been properly...

Страница 14: ...ithout an interchangeable head or head inserts installed this can damage the electrical tool If interchangeable head will not lock into QCS ensure ram is fully retracted by pressing the pressure relea...

Страница 15: ...rt fully charged battery recharge battery Bring tool and battery to correct operating range between 23 F 5 C and 122 F 50 C by allow ing the tool to sit in a conditioned room Contact RIDGID Technical...

Страница 16: ...with a light weight general purpose lubricating oil Wipe off any excess oil Set Up Operation 1 Prepare the connection to be crimped per the connector man ufacturer s instructions 2 Choose the appropr...

Страница 17: ...aluminum or copper wire Any other material such as steel can dull and damage the blades Inspection Maintenance Inspect the Scissor Cutting Head before each use for issues that could affect safe use 1...

Страница 18: ...until corrected 4 Inspect the electrical tool and any other equipment being used as directed in their instructions Make sure Punch parts are in good working condition 5 The QCS coupling is lubricated...