12-Volt Backup 

Sump Pump

Description

 The R12V is a battery operated back-up sump pump. It 
does not replace a regular pump. It is designed to provide 
protection in the event household electrical power fails.

Unpacking

Inspect this unit before it is used. Occasionally, products 
are damaged during shipment. If the pump or components 
are damaged, return the unit to the place of purchase for 
replacement. Failure to do so could result in serious injury or 
death.

Safety Guidelines

 This manual contains information that is very important 
to know and understand. This information is provided for 
SAFETY and to PREVENT EQUIPMENT PROBLEMS. 
To help recognize this information, observe the following 
symbols. 

 

Danger indicates an  imminently

 

hazardous situation which, if NOT 

avoided, WILL result in death or serious injury.

 

Warning indicates a potentially

 

hazardous situation which, if NOT 

avoided, COULD result in death or serious injury.

 Caution 

 

indicates a potentially

 

hazardous situation which, if NOT 

avoided, MAY result in minor or moderate injury.

 

Notice indicates important

 

information, that if NOT followed, MAY 

cause damage to equipment.

General Safety Information

 

Do NOT use to pump 

 

fl ammable or explosive fl uids 

such as gasoline, fuel oil, kerosene, etc. Do NOT 
use in a fl ammable and/or explosive atmosphere. 
pump SHOULD only be used to pump clear water. 
Fatal injury and/or property damage COULD result.

 

If the basement has

 

water or moisture on the 

fl oor, do NOT walk on wet area until all power is 
turned off. If the shutoff box is in the basement, 
call an electrician. Remove pump and either repair 
or replace. Failure to follow this warning COULD 
result in fatal electric shock.

 

All wiring must be performed by a

 qualifi ed electrician.

  

Do NOT expose battery to

 sparks 

or 

fl ame as an 

explosion or fi re COULD result.
 
 

Battery acid is corrosive

 

Avoid spilling on skin or clothing. Eye 

protection MUST be worn when handling the battery.

 

A check valve MUST be used on the

 

primary sump pump discharge.

 
 

A ground fault circuit interrupter

 

(GFCI) is required.

 

This pump MUST only be used to pump

 

clear water only. This pump is not 

designed to handle efl uent, salt water, brine, laundry discharge, 
or any other application which may cause caustic chemicals and/
or foreign materials. Pump damage MAY occur if used in these 
applications and WILL void the warranty.

Battery Information

The system is designed to operate most efficiently with sealed 
lead acid (SLA) batteries. Sealed lead acid batteries cost 
slightly more, but they can last longer. The oversize battery 
case (included) will accommodate a 12-volt SLA battery (up to 
a 27-frame size).

Be certain that the area around the batteries is well ventilated. 
Before servicing the batteries, blow away gasses by waving a 
piece of cardboard near the batteries.

 

Dangerous hydrogen gas CAN

 

be released from the batteries while 

charging. Sparks CAN ignite the gas in an enclosed space. Wear 
safetly goggles when connecting batteries. Battery connections 
SHOULD be made in a well ventilated area. 

 

Working in the vicinity of lead acid

 

batteries CAN be dangerous. Before 

making the connections or servicing the batteries, read and 
follow instructions on all applicable instruction manuals. To 
reduce the risk of battery explosion, follow the instructions in 
this manual and those published by the battery manufacturer, 
as well as those of any other equipment used in the surrounding 
area. 

An assistant should be present or close enough to come to 
your aid in the event of an emergency. Have a reliable source 
of fresh water and soap nearby in case batttery acid contacts 
skin or eyes. 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain 
the product described. Protect yourself and others by observing all safety information. Failure to comply with 
instructions could result in personal injury and/or property damage! Retain instructions for future reference.

REMINDER: Keep your dated proof of purchase for warranty purposes!  Attach it to this manual or file it for safekeeping.

Operating Instructions & Parts Manual  

R12V

© 2017, Ridge Tool Company.

3522 

00

-005   8/17

Содержание R12V

Страница 1: ... sump pump discharge A ground fault circuit interrupter GFCI is required This pump MUST only be used to pump clear water only This pump is not designed to handle efluent salt water brine laundry discharge or any other application which may cause caustic chemicals and or foreign materials Pump damage MAY occur if used in these applications and WILL void the warranty Battery Information The system i...

Страница 2: ...ng an explosion Installation Installation of this unit may take several hours Before disabling your main pump have ready an appropriate means of evacuating the sump 1 Turn power to main pump off 2 Pump must be instaled using 1 1 4 in or 1 1 2 in rigid PVC piping 2 Operating Instructions and Parts Manual This product contains a chemical that is known to the State of California to cause cancer or bi...

Страница 3: ...r 1 1 2 in PVC Pipe Float Switch 3 R12V Pump Installation The back up pump can be installed with a separate dedicated discharge line Method 1 or tied into an existing sump pump line Method 2 Unplug the existing AC pump Failure to follow this warning COULD result in fatal electric shock 1 Verify that the existing AC pump is in good working order If the AC pump is questionable it is typically recomm...

Страница 4: ... to accomodate a second pump 9 Glue a 45º elbow to the short pipe on the back up pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method 2 10 Glue a short piece of PVC pipe between the 45º elbow and the Y NOTE Check valves can be placed directly in the pump discharge if desired However for ease of disassembly it is recommended that check valves be placed ab...

Страница 5: ... or defective Red blinking Battery discharged below level where pumping can occur Motor is locked out by controller until battery is sufficiently charged to run pump d Plug in transformer and main AC pump When main AC power is out and when pump has been running the lights will indicate battery status 4 A chirping sound from the control box will accompany the red light indicating that the battery m...

Страница 6: ...ce if low or defective Pump cyles too frequently 1 Check valve problem 1 Check to make sure valves installed between primary pump discharge and back up sump pump are functioning properly Power failure light is on but A C power is available 1 Transformer is bad 2 Bad or no connection 3 Branch circuit breaker fuse blown 1 Replace transformer 2 Check that A C plug and transformer connection at lid ar...

Страница 7: ...ress any correspondence to Model number RIDGID PUMPS Serial number if any 101 Production Drive Part description and number as shown in parts list Harrison OH 45030 U S A Reference Number Description Part Number Quantity 1 Transformer 30221 WYN1 1 2 Pump 58324 WYN1 1 3 Lid Assembly 60184 WYN1 1 1 2 3 7 R12V ...

Страница 8: ...t alteration improper installation or maintenance modification repair by other than a service center authorized to repair RIDGID brand water pumps or failure to operate in accordance with RIDGID water pump written instructions WAYNE WATER SYSTEMS MAKES NO OTHER EXPRESS WARRANTIES REPRESENTATIONS OR PROMISES AS TO THE QUALITY OR PERFORMANCE OF ITS WATER PUMPS OTHER THAN THOSE SPECIFICALLY STATED IN...

Страница 9: ...anipular la batería debe protegerse los ojos Debe utilizar una válvula de chequeo en el orificio de descarga de la bomba principal parasumideros Se requiere un interruptor con dispositivo para desconexión automática en caso de fallas Esta bomba sólo debe usarse para bombear aguas limpias Esta bomba no está diseñada para bombear efluentes agua salada salmuera agua con detergentes o en ningún otro l...

Страница 10: ...sea utilizar tubería de descarga de 11 4 pulg NPT 3 2 cm será necesario instalar un adaptador no incluido Las tuberías de diámetro más pequeño reducirán el flujo la velocidad y el rendimiento de la bomba 10 Sp Manual de Instrucciones de Operación y Piezas Figura 1 Método 1 3 Corte una sección de 4 pies de 3 18 cm 11 4 pulg o de 3 81 cm 11 2 pulg de diámetro de un tubo de PVC rígido Pegue el tubo d...

Страница 11: ... que ajustarse para contener una segunda bomba 9 Pegue un codo de 45º al tubo corto en la bomba R12V Pegue un adaptador en Y al tubo corto en la bomba existente como se muestra en la ilustración del Método 2 10 Pegue un tramo corto de tubo de PVC entre el codo de 45º y la Y NOTA Las válvulas de retención pueden colocarse Figure 2 Método 2 directamente en la descarga de la bomba si lo desea Sin emb...

Страница 12: ...tor está bloqueado por el controlador hasta que la batería esté suficientemente cargada para activar la bomba d Conecte la bomba principal y el cargador al tomacorrientes Si la corriente alterna está apagada mientras la bomba está funcionando la luz le indicará la carga de la batería 4 Al escuchar un sonido cuando la luz roja se enciende le indica que necesita revisar o reemplazar la batería El vo...

Страница 13: ...re atención médica de inmediato Si el ácido entra en contacto con su piel o su vestimenta lávese inmediatamente con agua y jabón Nunca fume ni deje que haya chispas ni llamas en el área próxima a la batería Evite dejar caer herramientas de metal sobre los bornes de la batería porque pueden causar chispas o un cortocircuito en el sistema o en la batería provocando una explosión Siga los procedimien...

Страница 14: ...iberar la caja que cubre el impulsor Retire la obstrucción Vuelva a armar la bomba y vuelva a conectar La bomba funciona pero bombea poca o nada de agua 1 Revise la válvula que falta o que está mal instalada 1 Revise para asegurarse de que las válvulas de retención instaladas entre la bomba primaria y la bomba de respaldo para sumideros estén funcionando adecuadamente 2 Obstrucción en el tubo de d...

Страница 15: ...01 Production Drive Harrison OH 45030 U S A 1 Cargador 30221 WYN1 1 2 Bomba 58324 WYN1 1 3 Conjunto de cubierta protectora 60184 WYN1 1 No de Ref Descripción Número de pieza Ctd Sírvase proporcionar la siguiente información Número del modelo Número de serie de haberlo Descripciones y número de piezas tal como aparecen en la lista de piezas 1 2 3 15 Sp R12V ...

Страница 16: ...iento inadecuados modificación reparación por una persona que no esté autorizada por el centro de servicio para reparar bombas de agua de la marca RIDGID o la incapacidad de funcionar de acuerdo con las instrucciones escritas de la bomba de agua RIDGID WAYNE WATER SYSTEMS NO PROPORCIONA NINGUNA GARANTÍA REPRESENTACIÓN NI PROMESA EXPRESA SOBRE LA CALIDAD O EL FUNCIONAMIENTO DE SUS BOMBAS DE AGUA EX...

Отзывы: