Maintenance

WARNING

Remove battery before cleaning.

• Always clean the imager head and cable

after use with mild soap or mild detergent.

• Gently  clean  the  display  screen  with  a

clean dry cloth. Avoid rubbing too hard.

• Use only alcohol swabs to clean the cable

connections.

• Wipe the hand held display unit down with

a clean, dry cloth.

Reset Function

If the unit stops functioning and does not op-
erate, press the Reset Button 

(under the left

side port cover – Figure 4).

The unit may re-

cover to normal operation when re started. 

Optional Equipment

WARNING

To reduce the risk of serious injury, only
use  equipment  specifically  designed
and  recommended  for  use  with  the
RIDGID micro CA-350 Inspection Camera
such as those listed below. Other equip-
ment  suitable  for  use  with  other  tools
may be hazardous when used with the
micro CA-350 Inspection Camera.

micro CA-350 Inspection Camera

14

Storage

The RIDGID micro CA-350 Inspection Cam era
must be stored in a dry secure area between
-4°F (-20°C) and 140°F (60°C) and humidity
between 15% and 85% RH. 

Store  the  tool  in  a  locked  area,  out  of  the
reach of children and people unfamiliar with
the micro CA-350 Inspection Cam era.

Remove  the  battery  before  storage  or  ship-
ping.

Service and Repair

WARNING

Improper service or repair can make the
RIDGID micro CA-350 Inspection Camera
unsafe to operate.

Service  and  repair  of  the  micro  CA-350  In -
spec tion  Camera  must  be  performed  by  a
RIDGID  In dependent Authorized  Service
Center.

For information on your nearest RIDGID In -
depen dent Service Center or any service or
repair questions: 

Catalog

No.

Description

37108

3' (90 cm) Cable Extension

37113

6' (180 cm) Cable Extension

37103

Imager Head and Cable - 17 mm

37098

1 m length 6mm diameter imager

37093

4 m length 6mm diameter imager

37123

17 mm Accessory Pack (Hook,
Magnet, Mirror)

36758

AC Adapter

40623

Headset Accessory with
Microphone

Catalog

Plug 

No.

Region

Type

55193

Charger

USA, Canada and Mexico

A

55198

Charger

Europe

C

55203

Charger

China

A

55208

Charger

Australia & Latin America

I

55213

Charger

Japan

A

55218

Charger

United Kingdom

G

44798 Charger Cord

North America

A

44808 Charger Cord

Europe

C

44803 Charger Cord

China 

A

44813 Charger Cord

Australia & LA

I

44818 Charger Cord

Japan

A

44828 Charger Cord

United Kingdom

G

Catalog

No.

Model

Capacity

55183

RB-1225

12V 2.5Ah 

Batteries

All listed batteries will work with any catalog number RBC-121
Battery Charger. 

RBC-121 Chargers and Cords 

www.

.com

[email protected]

1.800.561.8187

Содержание micro CA-350

Страница 1: ...micro CA 350 Inspection Camera micro CA 350 Operator s Manual www com information itm com 1 800 561 8187 ...

Страница 2: ...ing with the AC Adapter 7 Installing Imager Head Cable or Extension Cables 7 Installing Accessories 7 Installing SD Card 8 Pre Operation Inspection 8 Tool and Work Area Set Up 8 Operating Instructions 9 Live Screen 10 Image Adjustment 10 Image Capture 11 Menu 11 Time Stamp 12 Language 12 Date Time 12 TV Out 12 Update Firmware 12 Speaker 12 Auto Power Off 12 Factory Reset 12 About 12 Transferring I...

Страница 3: ...etain product serial number which is located on nameplate Serial No WARNING Read this Operator s Manual carefully before using this tool Failure to understand and follow the contents of this manual may result in electri cal shock fire and or serious personal injury www com information itm com 1 800 561 8187 ...

Страница 4: ... and use common sense when operat ing equipment Do not use equipment while you are tired or under the influ ence of drugs alcohol or medication A moment of inattention while operating equipment may result in serious personal injury Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unex pected situations Use personal protective equipment ...

Страница 5: ...d OFF Any tool that can not be controlled with the switch is dan gerous and must be repaired Disconnect the batteries from the equip ment before making any adjustments changing accessories or storing Such preventive safety measures reduce the risk of injury Store idle equipment out of the reach of children and do not allow persons unfa miliar with the equipment or these in structions to operate th...

Страница 6: ...other substances that may be toxic infectious cause burns or other issues Appropriate personal pro tective equipment always includes safe ty glasses and gloves and may include equipment such as latex or rubber gloves face shields goggles protective clothing respirators and steel toed footwear Practice good hygiene Use hot soapy water to wash hands and other body parts exposed to drain contents aft...

Страница 7: ...h can be determined by turning the equipment OFF and ON the user is encouraged to try to cor rect the interference by one or more of the fol lowing measures Reorient or relocate the receiving antenna Power Supply 12V Li Ion Battery AC Adapter 12V 3 Amp Weight 5 5 lbs 2 5 kg Standard Equipment The micro CA 350 Inspection Camera comes with the following items micro CA 350 Handset 17 mm Imager 3 90 c...

Страница 8: ...Playback Mode Selecting this icon al lows you to view and delete previously saved images and video Menu Push select on this icon to be taken to the menu screen Select Pressing select from the live screen will take you to the playback screen Return Pressing return from the live screen will switch between camera and video Return will also back out of menu and playback mode LED Brightness Press right...

Страница 9: ...ill ap pear in the upper left hand portion of the screen along with the number of images or length of video that can be stored on the SD card Changing Installing Batteries The micro CA 350 is supplied without the bat tery installed If the battery indicator displays the battery needs to be recharged Re move the battery prior to storage 1 Squeeze the battery tabs See Figure 5 and pull to remove batt...

Страница 10: ...crease the risk of electrical shock micro CA 350 Inspection Camera 8 7 Check to make sure the connections be tween the handheld unit extension ca bles and imager cable are tight All con nections must be properly assembled for the cable to be water resistant Confirm unit is properly assembled 8 Check that the warning label is present firmly attached and readable Figure 10 Figure 10 Warning Label 9 ...

Страница 11: ...is water resistant IP54 but should not be submerged in water Determine if any chemicals are pres ent especially in the case of drains It is important to understand the specific safety measures required to work a round any chemicals present Contact the chemical manufacturer for required information Chemicals may damage or degrade the inspection camera Determine the temperature of the area and items...

Страница 12: ...de Selection 3 If the other inspection camera settings Time Stamp Language Date Time TV Out Update Firmware Speaker Micro phone Auto Power OFF Factory Reset need to be adjusted see Menu Section 4 Prepare the camera for inspection The camera cable may need to be pre formed or bent to properly inspect the area Do not try to form bends less than 5 13cm ra dius This can damage cable If inspecting a da...

Страница 13: ...tter button again to stop the video It may take several seconds to save the video if sav ing to the internal memory The micro CA 350 features an integrated mi crophone and speaker for recording and play back of audio with video A headset with inte grated microphone is included and may be used instead of the integrated speaker and microphone Plug the headset into the audio port on the right side of...

Страница 14: ... go black and image will be transmitted to exter nal screen To get live image on unit hit Power button to disable function Update Firmware Select Update Firmware to install the latest version of software on the unit Software will have to be loaded onto a SD Card and in serted into the unit Updates can be found at RIDGID com Speaker Select the Speaker icon in the menu and press Select Select ON or ...

Страница 15: ...r must be used to connect the micro CA 350 Inspection Camera to a Video Out port on the SeeSnake Inspec tion Equipment When connected in this man ner the micro CA 350 Inspection Camera will display the camera view and can be used for recording When connecting to SeeSnake Inspection Equipment microReel microDrain or nano Reel align the interconnect module connected to your reel with the cable conne...

Страница 16: ... CA 350 Inspection Camera Remove the battery before storage or ship ping Service and Repair WARNING Improper service or repair can make the RIDGID micro CA 350 Inspection Camera unsafe to operate Service and repair of the micro CA 350 In spection Camera must be performed by a RIDGID Independent Authorized Service Center For information on your nearest RIDGID In dependent Service Center or any serv...

Страница 17: ...ble regulations Contact your local waste management authority for more information For EC Countries Do not dispose of electrical equipment with house hold waste According to the European Guide line 2012 19 EU for Waste Electrical and Electronic Equipment and its implementation into national legislation elec trical equipment that is no longer usable must be collected separately and disposed of in a...

Страница 18: ...it will not turn ON Troubleshooting Loose cable connections Imager is broken Imager head covered by debris Battery low on power Dead battery Unit need to be reset Check cable connections clean if re quired Re attach Replace the Imager Visually inspect imager head to make certain it is not covered by debris Replace battery with charged battery Replace with charged battery Reset unit See Maintenance...

Отзывы: