1.1 Technical Parameter
Model
RD6006P
RD6006P-W
Input voltage range
7-70.00V
Output voltage range
0-60.000V
Output current range
0-6.0000A
Output power range
0-360.00W
Input voltage measurement resolution
0.01V
Output voltage setting measurement resolution
0.001V
Output current setting measurement resolution
0.0001A
Battery voltage measurement resolution
0.01V
Input voltage measurement accuracy
±(1%+5 digits)
Output voltage accuracy between setting and
measurement
±(0.5‰+4 digits)
Output current accuracy between setting and
measurement
±(1‰+6 digits)
Battery voltage measurement accuracy
±(0.5%+3 digits)
Automatic cut off current value when charging
Set by yourself
Output ripple typical
20mV VPP
Note
①
Working temperature range
-10
℃
~40
℃
External sensor Temperature detection range:
-10
℃
~100
℃
/0
℉
~200
℉
External
sensor
Temperature
detection
accuracy:
±3
℃
/±6
℉
Constant voltage mode response time
2ms
(
0.1A-5A Load
)
Constant voltage mode load regulation
±(0.1%+2 digits)
Constant current mode load regulation
±(0.1%+3 digits)
Capacity measurement range
0-9999.99Ah
Energy measurement range
0-9999.99Wh
Capacity and energy statistical error
±2
%
Buck working mode
Voltage drop >10%*VOUT+2V
Cooling fan start condition
Output current >4A or System temperature>45
℃
Cooling fan shut down condition when working
Output current <3.9A and System temperature <45
℃
Over temperature protection
System temperature >80
℃
Screen brightness setting
0-5(6 levels)
Screen
2.4 inch color HD display
Weight(with package)
About 0.62Kg
Product dimension
167*81*65mm
Support USB communication
Yes
Support WiFi communication
No
Yes
Note
①:
Ripple measurement method: noise and ripple are measured at X1 range, AC coupling, 20M