[Corct Temp: Init Fd: Clr/Sp], [Corct Temp: Init Fd: White]
• [S]
[Corct Temp: Init Fd: Clr/Sp], [Corct Temp: Init Fd: White]
• [BW/FC/FCS: Fuser Setting HQ]
[Corct Temp: Initial Feed]
• [FCS: Fuser Setting HQ]
[Corct Temp: Init Fd: Clr/Sp], [Corct Temp: Init Fd: White]
• [S: Fuser Setting HQ]
[Corct Temp: Init Fd: Clr/Sp], [Corct Temp: Init Fd: White]
3.
Select 1232: [Fusing Temperature], and then set the value in the following corresponding
settings to "5°C".
• [BW/FC/FCS]
[Corct Temp: Pre-Feed]
• [FCS]
[Corct Temp: Pre-Fd: Clr/Sp], [Corct Temp: Pre-Fd: White]
• [S]
[Corct Temp: Pre-Fd: Clr/Sp], [Corct Temp: Pre-Fd: White]
• [BW/FC/FCS: Fuser Setting HQ]
[Corct Temp: Pre-Feed]
• [FCS: Fuser Setting HQ]
[Corct Temp: Pre-Fd: Clr/Sp], [Corct Temp: Pre-Fd: White]
• [S: Fuser Setting HQ]
[Corct Temp: Pre-Fd: Clr/Sp], [Corct Temp: Pre-Fd: White]
4.
Print 10 or more A3 sheets.
5.
Has the problem been resolved?
Yes
Go to the next step.
No
Proceed to "(e) Decrease the heat roller temperature".
6.
Is the toner fusibility within the permissible range?
Yes
Finished!
No
Contact your service representative.
Uneven Density
73
Содержание TCRU/ORU
Страница 2: ......
Страница 10: ...8...
Страница 18: ...1 Before You Begin 16...
Страница 20: ...2 Troubleshooting Service Call Problems SC Codes 18...
Страница 48: ...For details about replacing the photoconductor unit see Replacement Guide 5 Image Quality Problem Lines 46...
Страница 60: ...6 Image Quality Problem Spots 58...
Страница 84: ...7 Image Quality Problem Full Page 82...
Страница 132: ...8 Troubleshooting Paper Delivery Problems 130...
Страница 160: ...9 Post Processing Option Troubleshooting 158...
Страница 183: ......
Страница 184: ...EN GB EN US EN AU D0AK 7433 2018...