721
-01
B
Finisher (D434) jogger motor error: Front
-02
B
Finisher (D434) jogger motor error: Rear
The jogger fences move out of the home position but the HP
sensor output does not change within the specified number of
pulses.
The 1st failure causes an original jam message, and the 2nd
failure causes this SC code.
Jogger HP sensor disconnected, defective
Jogger motor disconnected, defective
Jogger motor overloaded due to obstruction
Finisher main board and jogger motor connection loose,
defective
Finisher main board defective
128. Check and remove obstruction to the jogger motor.
129. Check the harness connections.
130. Replace the jogger HP sensor.
131. Replace the jogger motor.
132. Replace the main board of the finisher (
D434
).
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Finisher feed-out motor
The stack feed-out belt HP sensor does not activate within the
specified time after the stack feed-out belt motor turns on. The 1st
detection failure causes a jam error, and the 2nd failure causes
this SC code.
Stack feed-out HP sensor disconnected, defective
Feed-out motor disconnected, defective
Finisher main board connection to feed out motor
disconnected, defective
Motor overload due to obstruction
723
B
133. Check or clear obstructions around the motor drive
mechanism.
134. Replace the stack feed-out motor.
135. Replace the finisher main board.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Finisher stapler hammer motor error
724
B
Stapling does not finish within the prescribed time after the staple
hammer motor turns on. The 1st detection failure causes a jam
error, and the 2nd failure causes this SC code.
Содержание pro c901
Страница 38: ...Technical Bulletin PAGE 2 44 Model Aries P1 5 C1 5 Date 17 Feb 11 No RM077018 Correction Page 117 to 131...
Страница 50: ...Technical Bulletin PAGE 14 44 Model Aries P1 5 C1 5 Date 17 Feb 11 No RM077018 Page 133 to 149...
Страница 63: ...Technical Bulletin PAGE 27 44 Model Aries P1 5 C1 5 Date 17 Feb 11 No RM077018 Page 182 to 203...
Страница 101: ...Technical Bulletin PAGE 21 28 Reissued 07 Aug 2012 Model Aries P1 5 C1 5 Date 18 Feb 11 No RM077019g Appendixes...
Страница 132: ...Technical Bulletin PAGE 2 3 Reissued 15 Jun 11 Model Aries P1 5 C1 5 Date 12 May 11 No RM077028a Victoria...
Страница 133: ...Technical Bulletin PAGE 3 3 Reissued 15 Jun 11 Model Aries P1 5 C1 5 Date 12 May 11 No RM077028a Columbia...
Страница 266: ...Technical Bulletin PAGE 2 2 Model Aries P1 5 C1 5 Date 26 Jan 12 No RM077059...
Страница 290: ...Technical Bulletin PAGE 2 2 Model Aries P1 5 C1 5 Date 13 Feb 12 No RM077064...
Страница 441: ...Technical Bulletin PAGE 2 2 Model Aries P1 5 Date 12 Dec 13 No RM077101...
Страница 549: ...Technical Bulletin PAGE 5 35 Reissued 6 Jun 15 Model Aries C1 5 P1 5 D095 M077 Date 17 Jun 14 No RM077114a...