T
echnical
B
ulletin
PAGE: 1/1
Reissued: 6-Aug-02
Model:
Model K-P1
Date:
15-May-01
No.:
RG058005c
RTB Update
The items in bold italics have been added.
Subject:
NIB Firmware History
Prepared
by:
A. Ishiyama
From:
Technical Services sec. Service Planning Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other ( )
Printer NIB firmware history for the model K-P1 (G058/G056).
Part Number
Version
Production
G0585910G 1.56
For
service
parts*
G0585910G
1.54
September, ’01 production
G0585910F
1.53
June, ’01 production
G0585910E 1.51
April,
’01
production
G0585910D 1.49
February
’01
production
G0585910C
1.48
January ’01 production
G0585910B
1.47
December ’00 production
G0585910A 1.46
First
mass
production
*: This change has only been applied to Service Parts, as this model has been
discontinued.
Note:
The above firmware is being used on NA, Europe, and Asia models.
Descriptions Version
Firmware modified to correct the following:
1. SNMP
vulnerability
SNMP security vulnerabilities reported by CERT on Feb.12, 2002 have
been confirmed and fixed through the PROTOS c06-snmpv1 test suite.
-CERT:
http://www.cert.org/advisories/CA-2002-03.html
-PROTOS c06-snmpv1 test Suite:
http://www.ee.oulu.fi/research/ouspg/protos/testing/c06/snmpv1/
2. Cannot connect to Novell NDS (GFPR No. RC02010007)
The nearest NetWare Server informs the NIB of the alternate NetWare
Server address, where the NDS replica is stored. However, the NIB is
unable to interpret the message.
3. Firmware corrected so that the LCD displays “Printer is not ready” when
the printer is not yet in Ready status, e.g. when the cover is open.
1.56