Service Program Mode
M116/M117
5-10
SM
Engine Maintenance
Waste toner
Dsp
Independent-Supply
Toner
Sets the machine operation at "waste toner full" of
the refilled AIO.
[On or Off (Default)]
With main motor rotation count feature,
machine can be set to stop printing after
print total exceeds a certain set value. If
print count exceeds this value, then
"Replace Print Cartridge" remains in
display. Then a new AIO cartridge must
be installed. This feature is a safety
measure to prevent the used toner tank
from becoming full (there is no toner
overflow detection mechanism).
Test Pattern
Prints the test pattern.
Control
Mode
Corrects the face curl of paper.
0: OFF (28ppm)
1: Sets the engine speed at 14ppm after printing 1 minute.
2: Sets the engine speed at 14ppm.
3 to 255: not available
[0 to 255 / 0 / 1 /step]
AdjCharge
Bias
Charge bias correction for dirty background
0: OFF (Default)
1: ON
2 to 255: not available
[0 to 255 / 0 / 1 /step]
1200dpi LD
Power
Adjusts print density (density levels by increasing the number)
[31 to 155 / 112 (Default) / 1 /step]
Size Mism.
Det.
Sets whether to detect the size mismatch in ejecting the paper or not.
When “Yes” is set, the error recovery procedure is performed if size
mismatch is detected. When “No” is set, the error recovery procedure is
not performed regardless of the size mismatch.
[Yes (Default)/ No]
Содержание M116
Страница 1: ...M116 M117 SERVICE MANUAL...
Страница 13: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None...
Страница 14: ......
Страница 19: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None...
Страница 20: ......
Страница 24: ......
Страница 25: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None...
Страница 26: ......
Страница 29: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None...
Страница 30: ......
Страница 53: ...Paper Feed and Exit SM 4 23 M116 M117 Replacement and Adjustment 14 Registration sensor A...
Страница 71: ...Electrical Components SM 4 41 M116 M117 Replacement and Adjustment 21 PSU A x 4 x 1...
Страница 74: ...Others M116 M117 4 44 SM 3 Remove the quenching lamp A from the case hook x 3...
Страница 76: ......
Страница 77: ...SYSTEM MAINTENANCE REFERENCE REVISION HISTORY Page Date Added Updated New None...
Страница 78: ......
Страница 101: ...TROUBLESHOOTING REVISION HISTORY Page Date Added Updated New None...
Страница 102: ......
Страница 117: ...ENERGY SAVER REVISION HISTORY Page Date Added Updated New None...
Страница 118: ......
Страница 125: ...M116 M117 SERVICE MANUAL APPENDICES...
Страница 126: ......
Страница 128: ......
Страница 129: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None...
Страница 130: ......
Страница 136: ......
Страница 137: ...APPENDIX SP MODE TABLE REVISION HISTORY Page Date Added Updated New None...
Страница 138: ......
Страница 140: ......
Страница 141: ...APPENDIX TROUBLESHOOTING GUIDE REVISION HISTORY Page Date Added Updated New None...
Страница 142: ......
Страница 147: ...M355 PAPER FEED UNIT TK 1080 REVISION HISTORY Page Date Added Updated New None...
Страница 148: ......
Страница 150: ......
Страница 152: ......
Страница 153: ...REPLACEMENT AND ADJUSTMENT...
Страница 154: ......