0
CIP Training
L5160/L513
Maintenance
CIP Training
C7200 series
Adjustment Settings for Operators
•
When cleaning the media sensor on the underside of the carriage, do not touch the sensors
with your hand. Touching the sensors may cause malfunctions.
DWT207
•
Do not place any object on the platen as the carriage moves there.
•
When the carriage moves, it may make contact with media. Check that the media is not
deformed or that there is no floating media.
•
When 10 minutes or more have passed after the carriage moves, the machine will make a
buzzer sound. As nozzle dryness may cause a nozzle defect, perform nozzle maintenance
promptly.
•
For cleaning liquid, use only the manufacturer-recommended cleaning liquid bottle. For
details, see "List of Consumables".
1. Press the [Maintenance] key.
DWU102
2.
Press [Head Cleaning Maintenance].
3.
Press [Left Side Edge Position].
4.
Press [Execute].
The carriage moves to the left side edge position and a completion of movement message is
displayed.