SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC532-00
D
PSU Cooling fan error
The fan motor lock (rotating state) signal is sampled at 100 ms intervals
and the machine fails to receive the lock signal 50 times in succession.
• Failed fan motor
• Disconnected connector
• Harness disconnection
• Defective IOB
• Replace the fan motor.
• Check the connector.
• Replace the harness.
• Replace the IOB.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC541-00
A
Broken fusing (Center) thermistor wire
The condition whereby the temperature is -20 deg C or less for 5 seconds
has been detected 10 times or more.
• Broken thermistor wire
• Bad connector contact
• Clear the SP: fusing SC.
• Check the connector connection.
• Replace the fusing (Center) thermistor.
Service Call
147
Содержание Gim-MF1a
Страница 1: ...Model Gim MF1a b Machine Code M172 M173 Field Service Manual September 2014...
Страница 2: ......
Страница 32: ...2 Installation 30...
Страница 46: ...2 Operation Panel A x 5 4 Replacement and Adjustment 44...
Страница 55: ...PCDU PCDU 1 Press the release button and open the front cover A 2 Hold the grip to pull the PCDU A out PCDU 53...
Страница 73: ...4 Remove the bracket of the drawer connector and then remove the screws of the thermistor x3 Fusing 71...
Страница 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103...
Страница 122: ...5 Operation Panel page 43 Operation Panel 4 Replacement and Adjustment 120...
Страница 125: ...Service Program Mode 123...
Страница 184: ...6 Troubleshooting 182...
Страница 192: ...MEMO 190...
Страница 193: ...MEMO 191...
Страница 194: ...MEMO 192 EN...
Страница 195: ...Model Gim MF1a b Machine Code M172 M173 Appendices September 2014...
Страница 196: ......
Страница 214: ...1 Appendices Specifications 18...
Страница 299: ...MEMO 103...
Страница 300: ...MEMO 104 EN...