SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC277-00
SC277-10
D
LEDA communication error
The head type data was read three times in succession
(277-00)
• Defective ASIC
• Defective LEDA
(277-10)
• LEDA power source error
• Turn the main power OFF and then ON.
• Replace the LED head
SC300 (Image Processing – 1)
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC302
D
High voltage output error: Charge unit /Development unit
This SC is issued if the BCU detects a short in the power pack 10 times
consecutively.
Open circuit (+) / Short circuit (-)
• Turn the main power OFF and then ON.
• Replace the controller board.
• Check the connector connection.
6. Troubleshooting
142
Содержание Gim-MF1a
Страница 1: ...Model Gim MF1a b Machine Code M172 M173 Field Service Manual September 2014...
Страница 2: ......
Страница 32: ...2 Installation 30...
Страница 46: ...2 Operation Panel A x 5 4 Replacement and Adjustment 44...
Страница 55: ...PCDU PCDU 1 Press the release button and open the front cover A 2 Hold the grip to pull the PCDU A out PCDU 53...
Страница 73: ...4 Remove the bracket of the drawer connector and then remove the screws of the thermistor x3 Fusing 71...
Страница 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103...
Страница 122: ...5 Operation Panel page 43 Operation Panel 4 Replacement and Adjustment 120...
Страница 125: ...Service Program Mode 123...
Страница 184: ...6 Troubleshooting 182...
Страница 192: ...MEMO 190...
Страница 193: ...MEMO 191...
Страница 194: ...MEMO 192 EN...
Страница 195: ...Model Gim MF1a b Machine Code M172 M173 Appendices September 2014...
Страница 196: ......
Страница 214: ...1 Appendices Specifications 18...
Страница 299: ...MEMO 103...
Страница 300: ...MEMO 104 EN...