Code
Meaning
Suggested Cause/Action
2-51
The machine resets itself
because of a fatal
communication error
• If this is frequent, update the ROM, or replace the
FCU.
2-53
Snd msg() in the manual task is
an error because the mailbox
for the operation task is full.
• The user did the same operation many times, and this
gave too much load to the machine.
4-01
Line current was cut
• Check the line connector.
• Check for line problems.
• Replace the FCU or the NCU.
4-10
Communication failed because
of an ID Code mismatch
(Closed Network) or Tel.
No./CSI mismatch (Protection
against Wrong Connections)
• Get the ID Codes the same and/or the CSIs
programmed correctly, then resend.
• The machine at the other end may be defective.
5-10
DCR timer expired
• Replace the FCU.
5-20
Storage impossible because of
a lack of memory
• Temporary memory shortage.
• Test the SAF memory.
5-21
Memory overflow
5-23
Print data error when printing
a substitute rx or confidential rx
message
• Test the SAF memory.
• Ask the other end to resend the message.
5-25
SAF file access error
• Replace an SD card or HDD.
• Replace the FCU.
6-00
G3 ECM - T1 time out during
reception of facsimile data
• Try adjusting the rx cable equalizer.
• Replace the FCU.
6-01
G3 ECM - no V.21 signal was
received
6-02
G3 ECM - EOR was received
6-04
G3 ECM - RTC not detected
• Check the line connection.
• Check for a bad line or defective remote terminal.
• Replace the FCU.
Fax Error Codes
167
Содержание D127
Страница 1: ...Model S C5 Machine Code D127 D128 Field Service Manual 24 February 2012...
Страница 2: ......
Страница 14: ...Model S C5 201 12...
Страница 28: ...1 Product Information 26...
Страница 48: ...10 Remove the controller box 10 x 2 x 6 11 Remove the support bracket 11 x 3 2 Installation 46...
Страница 54: ...11 Remove the controller box 11 x 2 x 6 12 Remove the support bracket 12 x 3 2 Installation 52...
Страница 69: ...Installation Procedure 1 Open the right door A 2 Interface cover B x 1 3 Rear cover C x 5 Controller Options 67...
Страница 75: ...3 Preventive Maintenance Maintenance Tables See Appendices for the following information PM tables 73...
Страница 117: ...PSU 1 Open the front door 2 Copy tray p 78 Copy Tray 3 PSU assembly A x 7 x 10 4 PSU B x 8 x 7 Other Replacements 115...
Страница 128: ...2 Remove the clip A 3 Slide the shaft A and then remove the pin B 4 Replacement and Adjustment 126...
Страница 131: ...2 Guide plate A hook x 2 3 Guide plate A x 5 4 Release the clamps and disconnect the connectors x 3 x 2 ARDF 129...
Страница 132: ...5 Holder A x 1 6 Hinge A x 3 7 Bracket A x 2 4 Replacement and Adjustment 130...
Страница 135: ...3 Registration sensor A x 1 hooks ARDF 133...
Страница 142: ...11 Adjust the sub scan magnification SP4 008 001 The specification is 1 0 4 Replacement and Adjustment 140...
Страница 158: ...5 System Maintenance Reference 156...
Страница 198: ...6 Troubleshooting 196...
Страница 206: ...MEMO 204 EN...
Страница 207: ...Model S C5 Machine Code D127 D128 Appendices 26 November 2011...
Страница 208: ......
Страница 212: ...4...
Страница 365: ...For the settings of the image quality see the copier SP mode table System Service Mode 157...
Страница 366: ...3 Appendix SP Mode Tables 158...