062
Use Proxy
This SP setting determines if the proxy server is used when the machine communicates
with the service center.
063
Proxy Host
This SP sets the address of the proxy server used for communication between embedded
RCG-N and the gateway. Use this SP to set up or display the customer proxy server
address. The address is necessary to set up embedded RCG-N.
• The address display is limited to 127 characters. Characters beyond the 127th
character are ignored.
• This address is customer information and is not printed in the SMC report.
064
Proxy Port Number
This SP sets the port number of the proxy server used for communication between
embedded RCG N and the gateway. This setting is necessary to set up embedded RCG-
N.
• This port number is customer information and is not printed in the SMC report.
065
Proxy User Name
This SP sets the HTTP proxy authentication user name.
• The length of the name is limited to 31 characters. Any character beyond the 31st
character is ignored.
• This name is customer information and is not printed in the SMC report.
066
Proxy Password
This SP sets the HTTP proxy authentication password.
• The length of the password is limited to 31 characters. Any character beyond the
31st character is ignored.
• This name is customer information and is not printed in the SMC report.
3. Appendix: SP Mode Tables
72
Содержание D127
Страница 1: ...Model S C5 Machine Code D127 D128 Field Service Manual 24 February 2012...
Страница 2: ......
Страница 14: ...Model S C5 201 12...
Страница 28: ...1 Product Information 26...
Страница 48: ...10 Remove the controller box 10 x 2 x 6 11 Remove the support bracket 11 x 3 2 Installation 46...
Страница 54: ...11 Remove the controller box 11 x 2 x 6 12 Remove the support bracket 12 x 3 2 Installation 52...
Страница 69: ...Installation Procedure 1 Open the right door A 2 Interface cover B x 1 3 Rear cover C x 5 Controller Options 67...
Страница 75: ...3 Preventive Maintenance Maintenance Tables See Appendices for the following information PM tables 73...
Страница 117: ...PSU 1 Open the front door 2 Copy tray p 78 Copy Tray 3 PSU assembly A x 7 x 10 4 PSU B x 8 x 7 Other Replacements 115...
Страница 128: ...2 Remove the clip A 3 Slide the shaft A and then remove the pin B 4 Replacement and Adjustment 126...
Страница 131: ...2 Guide plate A hook x 2 3 Guide plate A x 5 4 Release the clamps and disconnect the connectors x 3 x 2 ARDF 129...
Страница 132: ...5 Holder A x 1 6 Hinge A x 3 7 Bracket A x 2 4 Replacement and Adjustment 130...
Страница 135: ...3 Registration sensor A x 1 hooks ARDF 133...
Страница 142: ...11 Adjust the sub scan magnification SP4 008 001 The specification is 1 0 4 Replacement and Adjustment 140...
Страница 158: ...5 System Maintenance Reference 156...
Страница 198: ...6 Troubleshooting 196...
Страница 206: ...MEMO 204 EN...
Страница 207: ...Model S C5 Machine Code D127 D128 Appendices 26 November 2011...
Страница 208: ......
Страница 212: ...4...
Страница 365: ...For the settings of the image quality see the copier SP mode table System Service Mode 157...