S-C4L Training
34
Slide 34
LD Safety Switches
PSU
BICU
LD Drive Board
+5VE
GND
+24V
REG
LD
PD
Vcc
LD
PD
M61880FP
+5VS
+5VS
Front/Right
Door
Switches
LD Safety Switches
Safety switches are installed at the front and right doors. The machine will cut
power to the LD drive board if either door is opened. The corresponding switch
cuts the power supply (+
5VS
) to the laser diode.
The safety switches are installed on the +24V line coming from the power supply
unit (PSU). The +24V supply must pass through these switches before
converting into the +
5VS
power that drives the laser.