Installing Options
53
M
Fasten the controller board to the printer with the two screws.
N
Align the power cable to the left side groove of the duplex unit, and then
slide the duplex unit in until it is connected to the printer.
If the duplex unit is not attached, this step is not necessary.
❒
After finishing installation, you can check the 1394 interface unit is properly
installed: Print the configuration page from the “List/Test Print” menu. If it
is installed properly, you will see “IEEE1394” for “Controller Option”.
❒
You need to make settings with the control panel before using the 1394 in-
terface unit. For more information, see
p.91 “IEEE 1394 Configuration”
❒
If the 1394 interface unit is not installed properly, repeat the procedure from
the start. If you cannot install it properly even after reinstallation, contact
your sales or service representative.