6.2.3 Discharge conditions and reaction
forces
At low temperatures:
Outlet lines must be protected against
freezing. This applies in particular if gas
cooling as a result of expansion is to be
expected or lines are laid outdoors.
With crystallising media:
In the case of media which tend to crystal-
lise, solidify or stick, appropriate action must
be taken to ensure that the solidification
process cannot take place in the inlet or
outlet lines or in the body (e.g. installed
rupture disc, insulation, heating). e.g.
installed rupture disc, insulation, heating
With gassing media:
In the case of gassing or vaporising liquids,
adequately dimensioned flashtraps must be
located in the direct vicinity of the valve.
6.3 Valve connecting dimensions
The main dimensions are contained in the dimension-
al drawing in
Section 10.3
.
6.4 Flange caps and gaskets
♦
Contamination of or damage to the sealing
surfaces is best avoided if the protective caps
remain on the flanges until just before installation.
We recommend the installation of gaskets so that the
sealing surfaces are not damaged by the mating
flanges.
If plastic sealing surfaces, e.g. on mating flanges
made of metal or enamel, can be damaged, use
PTFE-lined seals with a metal inlay.
These gaskets are available as special accessories in
the Richter range.
6.5 Direction of flow and
installation position
Qqq
The direction of flow must be observed
when installing the valve. It is indicated by a
direction arrow on the valve body.
♦
A mix-up of the inlet and outlet will result in the
valve becoming ineffective and the bellows may be
destroyed.
♦
Any fitting position can be chosen.
Fig. 5
6.6 Grounding
The valve must be grounded. This can be achieved in
the simplest way via the pipe screws using tooth lock
washers. One pipe screw per flange is underlaid with
toothed disks.
At the customer's request a setscrew M6 with a hex.
nut and washer will be provided at each flange as an
additional grounding connection.
Otherwise grounding must be ensured by different
measures e.g. a cable link.
6.7 Installation
♦
The plant components to be protected are to be
cleaned thoroughly prior to installation of the valve.
♦
Solids jeopardise the soft-sealing, high-precision
surfaces of the seat and plug and permanent leaks
could arise. The valve will leak.
♦
The overflow valve must be installed so that no
inadmissible mechanical or thermal stresses are
transmitted from the attached pipes to the body.
♦
Changes in length of the pipes due to temperature
are to be allowed for, e.g. through the installation
of expansion joints.
♦