background image

PitBoss

+ Tech Support:

 

1-833-786-7779

WARNING! 

 

Turn power to main pump off! 

WARNING! 

 

Electric shock hazard. DISCONNECT power before servicing. 

  

• 

Backup Pump must be installed using 1-1/2 in. rigid PVC pipe!

• 

DO NOT over tighten or cross-thread plastic fittings or check valves.

•  

Check valves MUST be installed in the discharge line of both the main AC pump and the  

back-up DC pump.

•  

Installation of this unit MAY take several hours. Before disabling your main pump, have a standby  

pump ready or an appropriate means of evacuating the sump basin. 

• 

Verify that the existing AC pump is in good working order. If the AC pump is questionable, replace.

• 

Remove any debris from the sump pit and surrounding area.

UNPACKING

Inspect this unit before beginning installation. Occasionally, products are damaged during shipment. If the 

pump or any components are damaged, contact Richtech Industries for replacement.

METHOD 1 (Separate discharge line) - See Figure 1

1. The backup pump has a 1-1/2 in. NPT discharge.
2.  Cut a 3 ft. section of 1-1/2 in. rigid PVC pipe. 

Glue 1-1/2 in. pipe to a threaded fitting. 

3. Screw pipe from step 2 into pump discharge.
4.  Place the pump with the 3 ft. section of PVC pipe on a 

solid, level surface in the sump pit. Do NOT place the 

pump on a loose or sandy surface. Small stones or 

sand may damage the pump resulting in pump failure.

5.  Attach a check valve (sold separately) to the top 

of the discharge pipe. A check valve is required for 

proper operation of system.

The remainder of the discharge pipe installation will vary 

depending on individual circumstances. Using sound 

plumbing practices, route the discharge pipe to an exterior 

wall by the shortest path. Keep turns to a minimum 

because they reduce flow output of the pump. 

The PitBoss

+ System can be installed with a separate discharge line (Method 1), or connected to 

an existing discharge line (Method 2).

FIGURE 1- 

Separate discharge line

INSTALLATION

WARNING

The PitBoss

+ System requires a 12V Deep Cycle Battery with a minimum 40 AMP/HR rating, 

75 AMP/HR rating (or higher) recommended. AGM Battery is strongly recommended.

BEFORE INSTALLING BACKUP PUMP

Содержание PitBoss Plus PBP12

Страница 1: ...rge 1 1 2 NPT MAX Flow 3000 GPH Power Supply Requirements 120 VAC 60 Hz 15 AMP Electrical Ratings 12 Amps 120 VAC 18 Amps 12 VDC Relative Humidity 0 to 80 Storage Temperature 0 to 70 C Operating Temperature 0 to 50 C SPECIFICATIONS PitBoss Model PBP12 The PitBoss System requires a 12V Deep Cycle Battery not included 40 amp hr minimum 75 amp hr or higher recommended SLA AGM Battery strongly recomme...

Страница 2: ...with wet hands WARNING The PitBoss System has not been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connection falls into the sump...

Страница 3: ...mp has a 1 1 2 in NPT discharge 2 Cut a 3 ft section of 1 1 2 in rigid PVC pipe Glue 1 1 2 in pipe to a threaded fitting 3 Screw pipe from step 2 into pump discharge 4 Place the pump with the 3 ft section of PVC pipe on a solid level surface in the sump pit Do NOT place the pump on a loose or sandy surface Small stones or sand may damage the pump resulting in pump failure 5 Attach a check valve so...

Страница 4: ... 2 8 Glue a short piece of PVC pipe between the 45º elbow and the Y THE CHECK VALVES FOR BOTH PUMPS MUST BE INSTALLED BELOW THE Y FITTING The remainder of the discharge pipe installation will vary depending on individual circumstances Using sound plumbing practices route the discharge pipe to an exterior wall by the shortest distance AFTER PLUMBING IS COMPLETED FOR BOTH METHODS 1 AND 2 Install flo...

Страница 5: ...e Red to positive Replace and lock the lid onto the battery case The PitBoss system will initialize and boot up All status LEDs will initially be GREEN Within 20 seconds the Power and WiFi status LEDs will turn RED 8 Plug the PitBoss controller into an AC wall outlet The Power status LED will turn green Consult your local codes for GFCI requirements 9 The PitBoss system is now ready for alert test...

Страница 6: ...WiFi Setup Mode on the PitBoss System Gently press and hold the WiFi setup button using a pencil paper clip The WiFi status LED will turn yellow and the device will enter setup mode after 3 seconds STEP 4 Prepare your device to connect to the PitBoss Monitoring Service On your device open the PitBoss app Allow PitBoss to access this device s location Allow all the time Create New Location in upper...

Страница 7: ...up mode after 3 seconds STEP 4 Prepare your device to connect to the PitBoss Monitoring Service On your device open the PitBoss app Create New Location in upper right corner and enter your information Return to the home button on your device STEP 5 Connect your device to the PitBoss System Open Settings on your device Select WiFi and then PitBoss Once connected to PitBoss go back to your home scre...

Страница 8: ...nty service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PitBoss products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed under the laws of the state of Ohio The warranty period will not be extended by any re...

Отзывы: