background image

18

English

MAINTENANCE

Good maintenance is essential for safe, economical and trouble-free operation. It will also help reduce air pollution. The 
purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition.

 

WARNING: 

Read and understand the Important Safety Rules before starting the generator.

 

DANGER: 

Shut off the engine before performing any maintenance. If the engine must be run, make sure 

the area is well ventilated. The exhaust contains poisonous carbon monoxide gas.

 

WARNING: 

When servicing, use only recommended or equivalent replacement parts. Use of any other 

parts could create a hazard or cause product damage.

 

WARNING: 

Allow hot components to cool to the touch prior to performing any maintenance procedure.

 

WARNING: 

Internal pressure can build in the engine crankcase while the engine is running. Removing the 

oil fill plug/ dipstick while the engine is hot can cause extremely hot oil to spray out of the crankcase and can severely 
burn skin. Allow engine oil to cool for several minutes before removing the oil fill plug/dipstick.

 

WARNING: 

Avoid skin contact with engine oil or gasoline. Prolonged skin contact with engine oil or gaso-

line can be harmful. Frequent and prolonged contact with engine oil may cause skin cancer. Take protective measures and 
wear protective clothing and equipment. Wash all exposed skin with soap and water. 

 

WARNING: 

Failure to perform periodic maintenance or not following maintenance procedures can cause 

the inverter to malfunction and could result in death or serious injury.

MAINTENANCE SCHEDULE

REGULAR SERVICE PERIOD

(1)

 

Perform at every indicated 
month or operating hour inter-
val, whichever occurs first.

ITEM

Before 
each use

Every 10 
hours

Every 4 
months or 
50 hours

Every year 
or 150 
hours

Every two 
years or 
300 hours

Complete 
machine

Visual inspec-
tion (condition, 
wear, leaks)

*

Clean

*

Engine oil

Check

*

Change

*

(2)

*

Air filter

Check

*

Clean

*

(3)

Spark plug

Check

*

Change

*

Fuel filter

Change

*

(4)

Carburettor

Check and clean

*

(4)

Valve 
clearance

Check and 
adjustment

*

(4)

(1) Log hours of operation to determine proper maintenance.
(2) The first changing of the engine oil shall be done on the first month or 10 hours, whichever is the earlier.
(3) Service more frequently when used in dusty areas.
(4) These items should be serviced by an authorized dealer unless the owner has the proper tools and is mechanically proficient.

Содержание Power Smith PGA2200i

Страница 1: ...or Operator s Manual SAVE THIS MANUAL FOR FUTURE REFERENCE WARNING To reduce the risk of injury user must read and understand this operator s manual before operating this product 888 552 8665 TOLL FRE...

Страница 2: ...ABLE OF CONTENT CALIFORNIA PROPOSITION 65 WARNING The engine exhaust from this product contains chemicals known to the state of California to cause cancer birth defects or other reproductive harm Cert...

Страница 3: ...hould be consid ered a permanent part of the generator and should remain with it if it is resold t Keep children and pets at least 10 feet away from the generator when it is in operation t Fuel is com...

Страница 4: ...ed area with the fuel tank empty Fuel should not be stored near the generator t Before use the generating set and its electrical equipment including lines and plug connections should be checked to ens...

Страница 5: ...zard Fuel and its vapors are extremely ammable Do not add fuel while the product is operating Hot Surface Exhaust Gases To reduce the risk of injury or damage avoid contact with any hot surface and do...

Страница 6: ...njury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Without Safety Alert Symbol Indicates important information not related to...

Страница 7: ...h running speed turn off the appliance or tool immediately to avoid equipment damage Always check the requirements of the tool or appliance being used compared to the rated output of the generator NOT...

Страница 8: ...Plug in the turn on the rst load preferably the largest load you have 3 Allow time to let the generator to run smoothly and the attached to operate properly 4 Connect and turn on the second load 5 Ag...

Страница 9: ...acement 79 8 cc Rated Speed 5000 RPM No Load Speed 3000 RPM Spark Plug TORCH E6TC Oil Tank Volume 400 CM3 Fuel Unleaded Gasoline Lubricate Oil SAE 10W30 above API SJ grade UNPACKING CONTENTS IMPORTANT...

Страница 10: ...gine Revolution Speed 13 Running Cumulative Hours 14 Ground Terminal 15 Digital Display Screen 16 Parallel Connectors 17 Display Locking Button 18 USB Ports 19 Running Hours Reset Button 20 Wattage In...

Страница 11: ...dle 30 Handle Locking Pin 31 Unfold Locking Pin 32 Transportation Handle 33 Spark Arrester 34 Transportation Wheel 35 Maintenance Cover 36 Muf er Shield 37 Spark Plug 38 Carburetor Drain Screw 39 Air...

Страница 12: ...arter is used along with the Engine Switch to start the generator s engine RESET BUTTON The reset button is used to restore power if an overload occurs To restore power remove all loads and depress th...

Страница 13: ...plugged into the control panel outlets CAUTION Starting the generator with loads already applied to it could result in damage to any appliance being powered off the generator during the brief start up...

Страница 14: ...etting the dirty and water in the fuel tank DANGER Risk of re and serious burns Never remove fuel cap when unit is running Shut off engine and allow the unit to cool at least ve minutes Remove cap slo...

Страница 15: ...ease according to the electric load it can help to decrease the fuel consumption If the auto idle switch is set in the OFF position the engine will run at high speed all the time Do not allow the reco...

Страница 16: ...reen and the overload indicator lights red instead press the reset button 3 Con rm that the appliances to be used are switched off and insert the plug of the AC appliances into the AC sockets The DC s...

Страница 17: ...DC receptacle of the generator 5 Connect the vehicle ground cable to the negative battery terminal OUTPUT AND OVERLOAD INDICATORS The Output Indicator will light green during normal operating conditi...

Страница 18: ...NING Avoid skin contact with engine oil or gasoline Prolonged skin contact with engine oil or gaso line can be harmful Frequent and prolonged contact with engine oil may cause skin cancer Take protect...

Страница 19: ...to a recycling center Do not discard it in a trash bin dump it on the ground or pour it down a drain CHECKING CLEANING AIR FILTER FIG 15 A dirty air lter will restrict air ow to the carburetor To prev...

Страница 20: ...re 1 8 to 1 4 turn after being seated 9 Reinstall the spark plug cap on the spark plug securely 10 Reinstall the maintenance cover CAUTION A loosen spark plug can overheat and damage the engine Overhe...

Страница 21: ...ight when putting the generator on a vehicle If the generator is left in an enclosed vehicle for many hours high temperature inside the vehicle could cause fuel to vaporize resulting in a possible exp...

Страница 22: ...nd pour about a tablespoon of clean engine oil into the cylinder Crank the engine several revolutions to distribute the oil and then reinstall the spark plug t Reinstall the spark plug cap on the spar...

Страница 23: ...spark plug The fuel tube is broken Contact with the local service for repair Engine lack of power Air lter is dirty Clean the air lter Spark plug is dirty Clean it Fuel lter was blocked Contact with t...

Страница 24: ...red by this warranty and it is not transferable Prior to returning your tool to store location of purchase please call Toll Free Help Line for possible solutions THIS PRODUCT IS NOT WARRANTED IF USED...

Страница 25: ...73 NOTES...

Страница 26: ...74 NOTES...

Страница 27: ...75 NOTES...

Страница 28: ...Richpower Industries Inc 736 Hampton Road Williamston SC USA www richpowerinc com 2018 08 V01...

Отзывы: