23
Revision 28
J2 Terminal:
(as per fig 17)
Terminal 1:
Optional External Close Push Button Switch.
Terminal 2:
Optional External Open Push Button Switch.
Terminal 3:
Optional External Stop Push Button Switch.
Terminal 4:
Common Terminal for All Optional Push Buttons.
(Hard-Wired keypad connection between terminals 4 & 5)
Terminal 5:
Optional External Open/Stop/Close Single Push Button
(does the 3 open/stop/close functions)
Terminal 6:
Optional External Push Button Pedestrian Switch
J5 Terminal
: Limit Switch and Accessories
Additional accessories sold separately
Terminal 7:
Power supply for accessories of J5 (+15V)
Terminal 8:
Photocell input (Normally Closed). If no photocell
is fitted use jumper between terminals 8 & 9.
Terminal 9:
Ground/Earth (GND)
Terminal 10:
Exit wand connection between terminals 9 & 10
Terminals 11, 12, and 13 are factory fitted (pre-wired)
Terminal 11:
Close spring limit switch
Terminal 12:
Spring limit switch common terminal
Terminal 13:
Open spring limit switch
Connecting Wires to the Terminal:
Using a screwdriver,
loosen the screw on the
side of the terminal.
Insert the wire into the
number on the terminal
that you are looking to
connect to. Refer to
Pages 20 & 21
Tighten with a
screwdriver to secure
the wire in place.