4
Revision 28
Gate Opening Default Setting Information:
The gate motor will open the gate to the right-hand side as its default setting (refer to fig 1).
Before Installing:
Test the motor by plugging it into a power source and pressing the remote. You will see the
motor cog turn. When it stops, press the remote again to see it turn in the opposite direction. This will give you an
understanding of the way in which the motor will move the gate.
Note: Ensure that the motor is unplugged before proceeding with installation. Please keep fingers away from the
motor cog whilst it is turning.
If your gate needs to open from the other direction (to the left, refer to fig 2) your motor needs to be mounted on
the left-hand side as shown, and dip switch 6 will need to be set to the ON position.
Any works done to the motor must be completed whilst the power is off, and the motor is unplugged
Left-Hand Opening: Motor
mounted on the left-hand side
Press the first/top button on the
remote.
The motor cog will turn counter-
clockwise, moving the gate frame.
Default operation: Motor
mounted on the right-hand side
The gate will then move in the set
direction. Default: right-hand open.
Fig 2
Fig 1
It is recommended that you allow a minimum 500mm bottom rail extension from your inside gate post
opening. This will enable you to have enough room to secure your gear rack and placement for the motor.
It is recommended that you allow a minimum 500mm bottom rail extension from your inside gate post
opening. This will enable you to have enough room to secure your gear rack and placement for the motor.