21
2. Potentiometers
There are 5 potentiometers located in the control board. They are used to adjust soft stop period, auto-close
time, open interval and close interval time between master gate opener and slave gate opener, and the stall
force.
Potentiometer A
is used to adjust the soft stop period of the gate opener. Turn the potentiometer clockwise to
increase the soft stop period, and turn it counter-clockwise to decrease the soft stop period. The soft stop period
can be adjusted steplessly from 1 to 5 seconds.
Potentiometer B
is used to adjust the auto close time of the gate opener. Turn the potentiometer clockwise to
increase the auto close time, and turn it counter-clockwise to decrease the auto close time. The auto close time
can be adjusted steplessly from 3 to 120 seconds.
Potentiometer C and potentiometer D
are used to adjust the open interval and close interval time between
the master gate opener and the slave gate opener respectively. Turn the potentiometer clockwise to increase
the interval time, and turn it counter-clockwise to decrease the interval time. The interval time can be adjusted
steplessly from 1 to 9 seconds.
Potentiometer E
is used to adjust the stall force the gate opener. Turn the potentiometer clockwise to increase
the stall force, and turn it counter-clockwise to decrease the stall force.