RICHARD LE DROFF 1000 Horizon FV Скачать руководство пользователя страница 3

GB 3/12

39417-05-16

1.

1.

TECHNICAL

TECHNICAL

CHARACTERISTICS

CHARACTERISTICS

FIRE 1000 HORIZON FV

Fire category

Intermittent

Rated heating output (1)

10 kW

Operation with door closed only
Average temperature of the smoke with door closed

269° C

Efficiency

80 %

Smoke flow

8,4 g/s

CO rate (13% O2)

0,1 %

Dust (13% O2)

40 mg/Nm

3

FUELS

Log size

50 cm

Nominal hourly load

2,8 kg

Reloading interval

45 mn

Prohibited fuels

all others including coal and derivatives

CHARACTERISTICS OF THE DUCTS

Smoke outlet nominal diameter

150 mm

Warm air distributor outlet diameter

150 mm

External air inlet diameter 

75 mm

Minimal dimensions of chimney block

20 x 20 cm

Min. Ø of tubing or insulated metal box

150 mm

Min. height above firebox

4 m

DRAUGHT (10 PA = 1 MM CE)

Nominal speed

12 Pa ± 2 Pa

Reduced speed

6 Pa ± 1 Pa

Max. admissible

20 Pa

Net / gross weight

180 kg / 208 kg

Manufacturer’s plate

in the ashbox

ACCESSORIES

Cold hand and isolating gloves

yes

Lower cross frame (4 screws)

yes

Combustion air nozzles Ø 75

yes

OPTIONS 

DA 1000 fairing kit

optional

Turbine 1000 kit

optional (DA 1000 required)

Warm air outlet nozzles (Ø 125 or Ø 150)

optional (DA 1000 required)

(firebox installing only)
Beam protection kit

optional

Frame (Bordure; Karo. Tech)

optional

Stand PS 1000

optional

Insert see § 2.1. § 3. 

Содержание 1000 Horizon FV

Страница 1: ...TION AND USE 05 16 39417 FIREBOX INSERT 1000 HORIZON FV 1 TECHNICAL CHARACTERISTICS 3 2 CONNECTION POSSIBILITIES 4 3 INSERT INSTALLATION 5 4 FIREBOX INSTALLATION 7 5 USE 10 6 MAINTENANCE 12 7 WARRANTY...

Страница 2: ...safe place The manufacturer s liability is limited to the supply of the appliance It may not be held liable in the event of any failure to respect these instructions The following are especially prohi...

Страница 3: ...distributor outlet diameter 150 mm External air inlet diameter 75 mm Minimal dimensions of chimney block 20 x20 cm Min of tubing or insulated metal box 150 mm Min height above firebox 4 m DRAUGHT 10 P...

Страница 4: ...DTU 24 1 Warm air is blown in front of the appliance Warm air distribution is possible with nozzles 125 or 150 option In this case the warm air blows out only over the firebox Fig 2 2 Combustion air...

Страница 5: ...ing is optimal with an approximately 40 m3 hour of fresh air consumption A system of ventilation french VMC a centralized ventilation system a n extractor hood can perturb the functioning of the fireb...

Страница 6: ...5 Lock the baffle in the firebox on the brackets 3 7 CONNECTION TO THE SMOKE FLUE Remove the smoke baffle 3 6 Connect the nozzle to the flue 3 3 from inside the firebox Lock the baffle into the firebo...

Страница 7: ...mbustion air supply connected outside A direct supply of air combustion in the room is possible respect the following recommendations 4 1 6 1 Combustion air not connected If no outside nozzle connecti...

Страница 8: ...s 4 6 1 2 3 5 6 7 8 9 10 FOYER 4 13 14 11 12 15 16 17 18 19 FIREBOX MONTAGE 1 Supporting wall class M0 materials 2 Decorative hood material according to model 3 Air access 4 Air access through firepla...

Страница 9: ...ahead of the firebox to the room fig 4 6 Rep 17 4 7 WARM AIR DISTRIBUTION Connect the warm air nozzless option available sp cific documentation Switch the warm air direction valve to direct warm air...

Страница 10: ...openings communicating with the outside of the hood be airtight as regards the lower part of the hood in order to avoid warm air escaping upwards Insulate the side resting against the wall the pipe a...

Страница 11: ...onal Start with a small fire then in stages increase the load The progressive rise in the temperature allows the materials to dilate slowly and stabilise Smoke and a smell will be given off at first d...

Страница 12: ...l operation When operating at reduced speed the clean glass system is less efficient 6 4 OBLIGATORY CHIMNEY SWEEPING The law in France requires that the chimney be swept twice a year including once du...

Отзывы: