FIRE 1000 HORIZON FV
Fire category
Intermittent
Rated heating output (1)
10 kW
Operation with door closed only
Average temperature of the smoke with door closed
269° C
Efficiency
80 %
Smoke flow
8,4 g/s
CO rate (13% O2)
0,1 %
Dust (13% O2)
40 mg/Nm
3
FUELS
Log size
50 cm
Nominal hourly load
2,8 kg
Reloading interval
45 mn
Prohibited fuels
all others including coal and derivatives
CHARACTERISTICS OF THE DUCTS
Smoke outlet nominal diameter
150 mm
Warm air distributor outlet diameter
150 mm
External air inlet diameter
75 mm
Minimal dimensions of chimney block
20 x 20 cm
Min. Ø of tubing or insulated metal box
150 mm
Min. height above firebox
4 m
DRAUGHT (10 PA = 1 MM CE)
Nominal speed
12 Pa ± 2 Pa
Reduced speed
6 Pa ± 1 Pa
Max. admissible
20 Pa
Net / gross weight
180 kg / 208 kg
Manufacturer’s plate
in the ashbox
ACCESSORIES
Cold hand and isolating gloves
yes
Lower cross frame (4 screws)
yes
Combustion air nozzles Ø 75
yes
OPTIONS
DA 1000 fairing kit
optional
Turbine 1000 kit
optional (DA 1000 required)
Warm air outlet nozzles (Ø 125 or Ø 150)
optional (DA 1000 required)
(firebox installing only)
Beam protection kit
optional
Frame (Bordure; Karo. Tech)
optional
Stand PS 1000
optional
Insert see § 2.1. § 3.