IMPORTANT

This appliance has been designed with care. To get the best out of it, as you are entitled to expect, and for your safety, please read carefully
these instructions for installation and use before starting work on the installation. 
The appliance must be connected using suitable fittings to an individual smoke flue specific to this appliance. A number of accessories are
also available, some of which must be fitted before installation.

- WARNING -

- This appliance is intended to burn wood, on no account may it be used as an incinerator or to burn liquid fuels, coal or derivatives. 
- All local or national regulations, as well as the European standards

(2)

must be respected as well as the European standards

(2)

when installing and using

the appliance. 

- The heating appliance is hot when in use, particularly the glazed front. It remains hot for a long time, even if the flames are no longer visible. Take

precautions to avoid all contact with the appliance (young children in particular). 

- Before accessing the electrical connection parts, all the power circuits must be switched off.
- This appliance must be installed in accordance with the specifications of the standards

(2)

in force.  Installation by a qualified professional is recom-

mended. 

- The instructions in this booklet must be followed scrupulously. Keep these instructions in a safe place.
- The manufacturer's liability is limited to the supply of the appliance. It may not be held liable in the event of any failure to respect these instructions. 
- The following are especially prohibited:
- The installation of materials that may be affected or damaged by the heat (furniture, wallpaper, woodwork) too close to the fire.
- The installation of any heat regenerator other than those recommended by the manufacturer.
- The use of any fuel other than natural wood and lignite.
- Any modification to the appliance or the installation not provided for by the manufacturer, which would release it from its liability and cancel the warranty.

Use exclusively spare parts recommended by the manufacturer.

- Any failure to comply with these indications is entirely the responsibility of the person who carries out the work and assembles the fire. 
- Installations in public places are subject to departmental sanitary regulations, which can be obtained from the Préfecture of your region. 
- The manufacturer reserves the right to modify, without prior warning, the presentation and the dimensions of its models as well as the design of the

assembly if necessary. The diagrams and texts contained in this document are the property of the manufacturer and may not be reproduced without
the latter's written permission. 

(1)

Nominal output in use with the door closed; according to tests carried out in accordance with EN 13229. 

(2)

EN 13229 Open fires and inserts burning solid fuel.

Ø 180

175

Ø 180

550

80

Ø 75

485

975

487

260

485

135

Ø 75

945

500

450

Ø 180

945

550

770

310

830

Содержание 1000 Horizon FV

Страница 1: ...TION AND USE 05 16 39417 FIREBOX INSERT 1000 HORIZON FV 1 TECHNICAL CHARACTERISTICS 3 2 CONNECTION POSSIBILITIES 4 3 INSERT INSTALLATION 5 4 FIREBOX INSTALLATION 7 5 USE 10 6 MAINTENANCE 12 7 WARRANTY...

Страница 2: ...safe place The manufacturer s liability is limited to the supply of the appliance It may not be held liable in the event of any failure to respect these instructions The following are especially prohi...

Страница 3: ...distributor outlet diameter 150 mm External air inlet diameter 75 mm Minimal dimensions of chimney block 20 x20 cm Min of tubing or insulated metal box 150 mm Min height above firebox 4 m DRAUGHT 10 P...

Страница 4: ...DTU 24 1 Warm air is blown in front of the appliance Warm air distribution is possible with nozzles 125 or 150 option In this case the warm air blows out only over the firebox Fig 2 2 Combustion air...

Страница 5: ...ing is optimal with an approximately 40 m3 hour of fresh air consumption A system of ventilation french VMC a centralized ventilation system a n extractor hood can perturb the functioning of the fireb...

Страница 6: ...5 Lock the baffle in the firebox on the brackets 3 7 CONNECTION TO THE SMOKE FLUE Remove the smoke baffle 3 6 Connect the nozzle to the flue 3 3 from inside the firebox Lock the baffle into the firebo...

Страница 7: ...mbustion air supply connected outside A direct supply of air combustion in the room is possible respect the following recommendations 4 1 6 1 Combustion air not connected If no outside nozzle connecti...

Страница 8: ...s 4 6 1 2 3 5 6 7 8 9 10 FOYER 4 13 14 11 12 15 16 17 18 19 FIREBOX MONTAGE 1 Supporting wall class M0 materials 2 Decorative hood material according to model 3 Air access 4 Air access through firepla...

Страница 9: ...ahead of the firebox to the room fig 4 6 Rep 17 4 7 WARM AIR DISTRIBUTION Connect the warm air nozzless option available sp cific documentation Switch the warm air direction valve to direct warm air...

Страница 10: ...openings communicating with the outside of the hood be airtight as regards the lower part of the hood in order to avoid warm air escaping upwards Insulate the side resting against the wall the pipe a...

Страница 11: ...onal Start with a small fire then in stages increase the load The progressive rise in the temperature allows the materials to dilate slowly and stabilise Smoke and a smell will be given off at first d...

Страница 12: ...l operation When operating at reduced speed the clean glass system is less efficient 6 4 OBLIGATORY CHIMNEY SWEEPING The law in France requires that the chimney be swept twice a year including once du...

Отзывы: