9
Table 1-4. Analog Output Module Pin Assignment
1.4
Analog Output Module Installation
To install or replace the analog output module (PN
85659), follow the steps listed in Section 1.2 on page 6
for opening the
420 Plus
enclosure.
Mount the analog output module on its standoffs in the
location shown in Figure 1-3 7 and plug the module
input into connector J9 on the
420 Plus
board. Connect
output cable to the analog output module as shown in
Table 1-4, then reassemble the enclosure (Section 1.5).
See Figure 1.8 on page 46 for analog output calibration
procedures.
1.5
Enclosure Reassembly
Once cabling is complete, close front cover and hook
draw latches. See Figure 1-4 below.
Figure 1-4.
420 Plus
Draw Latches and NTEP Seal
1.6
Board Removal
If you must remove the
420 Plus
CPU board, use the
following procedure:
1. Disconnect power to the indicator.
2. Open indicator using draw latches.
3. Disconnect power supply cable from connector
J7 on the
420 Plus
CPU board.
4. Unplug connectors J1 (load cell cable), J2
(digital inputs), J3 (EDP/RS-232), J4 (serial
communications), J6 (digital outputs), HE_J2
(display) and J10 & J11 (keypad ribbon
cables). If an analog output board is installed,
disconnect the analog output cable. See
Figure 1-3 7 for connector locations.
5. Remove the five screws from the CPU board,
then lift the board out of the enclosure.
To replace the CPU board, reverse the above
procedure. Be sure to reinstall cable ties to secure all
cables inside the indicator enclosure.
Pin
Signal
1
+ Current Out
2
– Current Out
3
+ Voltage Out
4
– Voltage Out
Draw
Latches
NTEP
Approved
Seal
Top of
Indicator
Содержание Revolution SURVIVOR 420HE
Страница 55: ......
Страница 56: ...Rice Lake Weighing Systems 07 19 PN 87972 Rev B...