420HE  Installation Manual

1.7.3

Setting the Digital Filter Parameters

Fine-tuning the digital filter parameters greatly

improves indicator performance in heavy-vibration

environments. Use the following procedure to

determine vibration effects on the scale and optimize

the digital filtering configuration.

1. In  setup  mode,  set  all  three  digital  filters

(DIGFL1, DIGFL2, DIGFL3) to 1. Set

DFTHRH to NONE. Return indicator to

normal mode.

2. Remove all weight from the scale, then watch

the indicator display to determine the

magnitude of vibration effects on the scale.

Record the weight below which all but a few

readings fall. This value is used to calculate the

DFTHRH parameter value in Step 4.
For  example,  if  a  heavy-capacity  scale

produces vibration-related readings of up to 50

lb, with occasional spikes to 75 lb, record 50 lb

as the threshold weight value.

3. Place the indicator in setup mode and set the

digital filters (DIGFL

x

) to eliminate the

vibration effects on the scale. (Leave

DFTHRH set to NONE.) Reconfigure as

necessary to find the lowest effective values

for the DIGFL

x

 parameters.

4. With optimum values assigned to the DIGFL

x

parameters, calculate the DFTHRH parameter

value by converting the weight value recorded

in Step 2 to display divisions:

threshold_weight_value / DSPDIV

In  the  example  in  Step  2,  with  a  threshold

weight  value  of  50  lb  and  a  display  division

value of 5lb: 

50 / 5lb = 10DD. 

DFTHRH should

be set to 10DD for this example.

5. Finally,  set  the  DFSENS  parameter  high

enough to ignore transient peaks. Longer

transients (typically caused by lower vibration

frequencies) will cause more consecutive

out-of-band readings, so DFSENS should be

set higher to counter low frequency transients.
Reconfigure  as  necessary  to  find  the  lowest

effective value for the DFSENS parameter.

1.8

Analog Output Calibration

The following calibration procedure requires a multimeter to measure voltage or current output from the analog

output module. If the option is not already installed, see Section 1.3.5 on page 8.

The  analog  output  must  be  calibrated 

after

  the  indicator  itself  has  been  configured  (Section 1.0)  and

calibrated (Section 1.0).

Figure 1-5. Analog Output Menu

1. Enter  setup  mode  and  go  to  the  ALGOUT

menu (see Figure 1-5).
• Set  OFFSET  to  0%  for  0–10  V  output,

20% for 4–20 mA output

• Set  MIN  to  lowest  weight  value  to  be

tracked by the analog output

• Set  MAX  to  highest  weight  value  to  be

tracked by the analog output

2. Connect multimeter to analog output:

• For  voltage  output,  connect  voltmeter

leads to pins three and four

• For current output, connect ammeter leads

to pins one and two

3. Adjust  zero  calibration:  Scroll  to  the

TWZERO parameter. Check voltage or current

reading on multimeter. Press and hold   or 

to adjust the zero value up or down.

4. Adjust span calibration: Scroll to the TWSPAN

parameter. Check voltage or current reading on

multimeter. Press and hold   or   to adjust the

span value up or down.

5. Final zero calibration: Return to the TWZERO

parameter and verify that the zero calibration

has not drifted. Press and hold   or   to

re-adjust the zero value as required.

6. Return  to  normal  mode.  Analog  output

function can be verified using test weights.

Note

XXXXXXX

XXXXXXX

ALGOUT

DIG IN

SETPNT

XXXXXXX

PROGRM

PFORMT

SERIAL

CALIBR

XXXXXXX

CONFIG

FORMAT

SOURCE

GROSS

0%

20%

OFFSET

ERRACT

FULLSC

HOLD

0.000000

number

MIN

    OFF

    ON

       MNNEG

   MAX

NET

MAXNEG

ZEROSC

XXXXXXX

VERS

  10000

number

    OFF

    ON

Содержание Revolution SURVIVOR 420HE

Страница 1: ...87972 Rev B SURVIVOR 420HE Hostile Environment Digital Weight Indicator Version 1 15 Installation Manual...

Страница 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Страница 3: ...Parts 10 1 0 Configuration 13 1 1 Configuration Methods 13 1 1 1 Revolution Configuration 13 1 1 2 EDP Command Configuration 13 1 1 3 Front Panel Configuration 14 1 2 Menu Structures and Parameter De...

Страница 4: ...matting 35 1 1 Print Formatting Commands 35 1 2 Customizing Print Formats 35 1 2 1 Using the EDP Port 36 1 2 2 Using the Front Panel 36 1 2 3 Using Revolution 37 1 0 Appendix 38 1 1 Error Messages 38...

Страница 5: ...result in damage to equipment or corruption to and loss of data Safety Precautions Do not operate or work on this equipment unless you have read and understand the instructions and warnings in this ma...

Страница 6: ...ions 1 1 Operating Modes The 420 Plus has four modes of operation Normal Primary mode Normal mode is the default mode of the indicator The indicator displays gross or net weights as required using the...

Страница 7: ...nnunciators and Normal Mode Key Functions 1 3 LED Annunciators The 420 Plus display uses a set of six LED annunciators to provide additional information about the value being displayed Gross and Net a...

Страница 8: ...by the Net annunciator 1 4 2 Toggle Units Press the UNITS key to switch between primary and secondary units The appropriate units LED under the display is lit 1 4 3 Zero Scale 1 In gross mode remove a...

Страница 9: ...e or setpoint number prompt Press the UP key until SETPNT is displayed Press the UP key once more to exit See Figure 1 2 1 4 9 Turn Setpoint On or Off To turn a setpoint on or off at the front panel e...

Страница 10: ...rminals PN 71125 for connectors J2 and J3 and one four position screw terminal PN 71126 for connector J6 see figure 1 3 Three reducing glands PN 15664 One capacity label PN 42350 Three each of groundi...

Страница 11: ...ield and the grounding clamp Route stripped cables through cord grips and clamps Ensure shields contact grounding clamps as shown in Figure 1 2 Tighten grounding clamp nuts Finish installation using c...

Страница 12: ...ge 13 for configuration information 1 3 4 Digital I O Digital inputs can be set to provide several indicator functions including all keypad functions The inputs are active on with low voltage 0 VDC an...

Страница 13: ...Plus Draw Latches and NTEP Seal 1 6 Board Removal If you must remove the 420 Plus CPU board use the following procedure 1 Disconnect power to the indicator 2 Open indicator using draw latches 3 Disco...

Страница 14: ...ng 1 13 87958 CPU board 1 15 15655 Cable grips 8 NPT 3 16 15656 Lock nut 8 NPT 3 17 85202 Power cord 120 VAC 1 See Figure 1 6 12 18 87971 Switch assembly 6 pushbutton 1 See Figure 1 5 11 19 87969 Filt...

Страница 15: ...11 Figure 1 5 420 Plus Assembly Drawing To Power Supply From Power Supply From Power Supply 1 2 3 4 5 6 7 8 9 10 11 12 13 15 18 19 20 16...

Страница 16: ...nual Figure 1 6 420 Plus Assembly Drawing Grounding Detail Ground Wire From Power Cord 17 Ground Screw In Bottom Panel 12 2X Cable Tie Wires Using 2 Holes Provided In Bracket Wire Tie Squares 29 30 28...

Страница 17: ...llows configuration data to be retrieved from one indicator edited then downloaded to another To use Revolution do the following 1 Install the Revolution module on an IBM compatible personal computer...

Страница 18: ...ad tare function sample rate and digital filtering parameters FORMAT Format Set format of primary and secondary units display rate CALIBR Calibration Calibrate indicator See Section 1 0 on page 27 for...

Страница 19: ...of the 420 Plus menu structures In the actual menu structure the settings you choose under each parameter are arranged horizontally To save page space menu choices are shown in vertical columns The fa...

Страница 20: ...cluding print tare and zero require the scale to be at standstill Maximum legal value varies depending on local regulations If this parameter is set to 0 the standstill annunciator will be set continu...

Страница 21: ...nu Parameters Continued XXXXXXX XXXXXXX XXXXXXX XXXXXXX DSPDIV MULT UNITS DECPNT 0 453592 5D 2D 1D number PRIMAR SECNDR 6SEC 4SEC 3SEC 2 5SEC 2SEC 1 5SEC 750MS 500MS 250MS 8SEC DSPRAT DSPDIV UNITS DEC...

Страница 22: ...Secondary Units SECNDR Parameter DECPNT 88888 8 888888 888880 8 88888 88 8888 888 888 8888 88 Decimal point location Determines the location of the decimal point or dummy zeros in the secondary unit d...

Страница 23: ...RO Press Enter to remove an offset value from the zero and span calibrations Use this parameter only after WZERO and WSPAN have been set See Section 1 1 on page 27 for more information about using thi...

Страница 24: ...Whenever the print key is pressed and data is sent out the word PRINT is momentarily put on the remote display Level 3 Submenus EDP Port and Printer Port BAUD 9600 19200 38400 300 600 1200 2400 4800...

Страница 25: ...lows tares to be cleared at any weight value NTEP and OIML modes allow a new tare to be acquired even if a tare is already present In CANADA mode the previous tare must be cleared before a new tare ca...

Страница 26: ...COLAN COMMA Specifies the time separator character PROGRM Menu Parameter Choices Description Table 1 6 Program Menu Parameters Continued XXXXXXX XXXXXXX XXXXXXX XXXXXXX GFMT Display rst 6 characters...

Страница 27: ...UE number Display and edit the setpoint value TRIP HIGHER LOWER INBAND OUTBND Trips the setpoint when the weight is higher or lower than the setpoint value or is within or outside of the band value LO...

Страница 28: ...ue CLRCN resets the consecutive number to the value specified on the CONSTU parameter PROGRM menu KBDLOC disables the keypad while the digital input is held low HOLD holds the current display Releasin...

Страница 29: ...fies how the analog output responds to system error conditions Possible values are FULLSC Set to full value 10 V or 20 mA HOLD Hold current value ZEROSC Set to zero value 0 V or 4 mA MIN 000000 number...

Страница 30: ...used to check the software version and reg version installed in the indicator You can also check the indicator model Figure 1 14 Version Menu XXXXXXX ALGOUT XXXXXXX XXXXXXX VERS DIGIN SETPNT PROGRM PF...

Страница 31: ...calibration weight Use the procedure shown in Figure 1 4 15 to enter the actual value of the test weights to be used for the span calibration Press to store the entered WVAL value and go to span cali...

Страница 32: ...the scale Clear the scale and click OK to begin zero calibration If your test weights require hooks or chains place the hooks or chains on the scale for zero calibration 5 When zero calibration is co...

Страница 33: ...the keys on the front panel of the indicator Most commands can be used in both setup and weighing mode Several of the commands serve as pseudo keys providing functions that are not represented by a k...

Страница 34: ...value Use no spaces before or after the equal sign If you type an incorrect command or value the display reads Changes to the parameters are saved as they are entered but typically do not take effect...

Страница 35: ...ue WSPAN Span calibration REZERO Rezero LC CD Set deadload coefficient value LC CW Set span coefficient value Table 1 5 CALIBR EDP Commands Command Description Values EDP BAUD EDP port baud rate 300 6...

Страница 36: ...tring See Section 1 0 on page 35 for detailed information NFMT Net demand print format string Table 1 8 PFORMT EDP Commands Command Description Values SP1 SP2 SP1 ENABLE SP2 ENABLE Setpoint enable OFF...

Страница 37: ...LGOUT EDP Commands Command Description Response Format UID Set unit ID nnnnnnn SD Set date MMDDYY DDMMYY YYMMDD enter using DATEFMT specified ST Set time hhmm enter using 24 hour format SX Start EDP s...

Страница 38: ...arameters to the PC as ASCII formatted text 1 2 2 Downloading Configuration Data from PC to Indicator Configuration data saved on a PC or floppy disk can be downloaded from the PC to an indicator This...

Страница 39: ...rint format string includes the output field length of the print formatting commands not the command length For example if the indicator is configured to show a decimal point the G command generates a...

Страница 40: ...ing the Front Panel If you have no access to equipment for communication through the EDP port or are working at a site where such equipment cannot be used you can use the PFORMT menu see Figure 1 1 to...

Страница 41: ...the formatting commands NL and SP required by the front panel or EDP command methods Using Revolution you can type text directly into the grid then select weight value fields from the tool bar and pl...

Страница 42: ...r EACKSM A D calibration checksum error A D converter requires recalibration Call RLWS Service EFCKSM Printer format checksum error Call RLWS Service ELCKSM Load cell calibration checksum error Recali...

Страница 43: ...which annunciators are currently displayed on the indicator front panel The ZZ command returns the currently displayed weight and a decimal number representing the LED annunciators currently lit The...

Страница 44: ...gure 1 1 Continuous Output Data Format STX POL wwwwwww UNIT G N S TERM ASCII 02 decimal Weight data 7 digits right justi ed with decimal point leading zero supression Overload Underrange Display over...

Страница 45: ...46 f 102 66 Ctrl G BEL 07 07 39 27 G 71 47 g 103 67 Ctrl H BS 08 08 40 28 H 72 48 h 104 68 Ctrl I HT 09 09 41 29 I 73 49 i 105 69 Ctrl J LF 10 0A 42 2A J 74 4A j 106 6A Ctrl K VT 11 0B 43 2B K 75 4B...

Страница 46: ...B 235 EB 140 8C 1 4 172 AC 204 CC 236 EC 141 8D 173 AD 205 CD 237 ED 142 8E 174 AE 206 CE 238 EE 143 8F 175 AF 207 CF 239 EF 144 90 176 B0 208 D0 240 F0 145 91 177 B1 209 D1 241 F1 146 92 178 B2 210 D...

Страница 47: ...ters Figure 1 2 shows the 7 segment LED character set used to display alphanumeric characters on the 420 Plus front panel Figure 1 2 420 Plus Display Characters 9 E Q F R G S 0 H T 1 I U 2 J V 3 K W 4...

Страница 48: ...and the secondary decimal point is set to 8888 88 the indicator will overflow if 5 tons or more are applied to the scale With 5 tons applied and a conversion factor of 2000 the secondary units displa...

Страница 49: ...4 8 8 With this configuration each A D reading has a 1 in 20 effect on the displayed weight value Setting the filters to 1 effectively disables digital filtering 1 7 2 DFSENS and DFTHRH Parameters Th...

Страница 50: ...use more consecutive out of band readings so DFSENS should be set higher to counter low frequency transients Reconfigure as necessary to find the lowest effective value for the DFSENS parameter 1 8 An...

Страница 51: ...functions in test mode Note that because the Test Menu functions are all on a single menu level the GROSS NET key has no function Press the ZERO key to exit test mode Table 1 7 summarizes the test me...

Страница 52: ...ory Test Green Pass Red Fail LED ANA Red Not Implemented Analog Option Card Digital Input Output Status DO 1 Digital Out 1 On when lit active low DO 2 Digital Out 2 On when lit active low DI 1 Digital...

Страница 53: ...age output 0 10 VDC Load resistance 1K minimum Current output 0 20 4 20 mA External loop resistance 500 maximum Digital Specifications Microcomputer Phillips PXAG30K main processor 19 6608 MHz Digital...

Страница 54: ...caused by accident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged non conformities Such equipment has not been modifie...

Страница 55: ......

Страница 56: ...Rice Lake Weighing Systems 07 19 PN 87972 Rev B...

Отзывы: