MEASUREMENT  SYSTEMS  INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

Temperature Range

 

• -20° C to +60° C Operating (-4° F to 140° F)

 

• -30° C to +80° C Storage  (-22° F to 176° F)

Approvals (planned or pending)

 

NTEP, OIML, Factory Mutual, FCC

Radio Link

Frequency Hopping Spread Spectrum in 64 networks@ 2.4 GHz. 

Radio functions in the ISM band, license free in the USA and 

Europe. 10mW (low power) or 100mW (high power) average 

output.

Radio Link Effective Range

 

Typically 500’ (150 meters) indoors, 1000’ (300m) outdoors 

with standard antennas. The 9750A range will increase if the 

CellScale is equipped with a long range antenna.

RFI/EMI Shielding

 

Exceeds NIST HB44 and CE Standards.

Housing

 

Reinforced PVC. ‘O’ ring gasketed. NEMA 3, IP54

Connectors

 

Power – 2.5 mm Coax, center pin positive. 

 

Comm 1 – 9 Pin D (DE-9P)

Weight

 

 2.2 lb. (1.0 kg)

STANDARD FEATURES

Scale Monitoring

 

Each 9750A can log on to 64 different networks allowing it to 

serve up to 64 separate CellScales. Easy 1 button scale changes. 

Each CellScale can access 32 independent Scale Channels. Sup-

ports display of up to 8 CellScale channels simultaneously.

Calibration

Via RF, the 9750A can calibrate any CellScale system. The 

system is sealed at the CellScale.

Keypad

24 keys – 6 user programmable (12 functions), 11 key alphanu-

meric, and 7 scale control keys

Push button Functions

Fixed keys:

 

Power: On/Off

 

Zero: Remove residual weight on scale

 

Net/Gross: Switch between Tared weight (Net) and Gross weight

 

Tare: Tare out empty container weight and switch to Net mode. 

 

Alpha: Allows alpha character entry, upper and lower case

 

Enter: Store parameters or enter menus

 

Setup: Setup scale functions

 

0-9 with Alpha characters

PROGRAMMABLE FEATURES

  •  Automatic or Manual Tare entry

  •  32 Set points with messaging capability 

  •  Peak Hold – for capturing maximum readings

  •  32 programmable ID Codes

  •  Each ID code has an 8 character name, two 20 character 

print strings, and stores independently units, tare, total with 

weighments counter, and full statistics.

  •  Selectable Automatic Power-Down, for battery power savings.

  •  Backlight On, Off or Automatic

  •  Lock –The user can lock any or all features to prevent tampering 

with setups. Protected by password. 

  •  RS-232 I/O will output on demand, on a change, regular time 

interval, on a set point, on Total, by computer control or continu-

ously.

  •  RS-232 I/O provides full output formatting to interface with 

computers, printers, scoreboards and most serial devices.

  •  Send / Print: Output user confi gured print strings to Comm Ports 

or via RF to any connected host.

  •  Manual or Automatic Data Logging. Up to 128 kbytes of storage 

(adequate for up to 6400 weight recordings)

Display

 

• 64 x 128 Full Graphics Module

 

• Multiple Font sizes, up to 8 lines of 21 characters

 

• Annunciators for measurement modes

 

• LED backlighting with timer for battery savings

Calibration Parameters

 

See CellScale specifi cations. All calibration data is stored in 

the CellScale, allowing any 9750A to use any CellScale based 

system without recalibration. 

Real Time Clock

 

Supports date / time stamping in US or European formats. 

Backed up by a replaceable Lithium Battery (Typical life >5 

years).

Data I/O

 

1 Comm Port, RS-232. Baud Rates: 300, 600, 1200, 2400, 4800, 

9600, 14.4k, 19.2k, 28.8k, 38.4k, 57.6k, 76.8k, 115.2k, and 

230.4k. Software and hardware handshaking. 

ID

 

Up to 32 IDs can be stored in any connected CellScales and are 

identifi ed by Alpha-numeric ID names. Each ID stores Totals, 

Statistics, Tare values, and two 20 byte string messages. 

Totalizing & Statistics

 

Stored in connected CellScales, displayed on the 9750A. Total 

weight up to 999,999,999. Weighments counter up to 65,535. 

Totals and statistics are stored with each ID register. Each ID 

code keeps full statistics on totaled weighments. Included are 

Standard Deviation, Average, Minimum, Maximum, and Coef-

fi cient of Variance.

Data Logging

 

Two independent 64kByte battery backed memories for manual 

or automatic storage of weight data. Automatic storage based on 

time interval, set points, or loading conditions.

Audible Set Points or Totalize Indicator

 

Coupled with the internal Set Points, an alarm can sound at any 

weight. Can also be used for accept or an out-of-limits indicator 

for blind check-weighing. Can also be confi gured as a totalize 

alert.

Text Messaging

 

Able to receive and transmit user entered messages for display 

on the LCD. The 9750A replies with auto and manual replies 

to received messages. Audible alerts possible by including the 

ASCII “BEL” character.

Bar Code Interface

 

The 9750A can directly read industry standard Bar Code scan-

ners and append the bar code data to weight, date, and time data 

generated by the CellScale. Pass thru data can be sent directly to 

host computers via MSI RF modems.

ACCESSORIES

AC Adapter / Battery Charger

 

90-260 Vac or 130-350 Vdc Option. 

Vehicle Charge Adapter

 

Cigarette type charge adapter. 12-24VDC, fused at 5A

Bar Code Scanner

 

Several scanner types available. Contact MSI for specifi c appli-

cation information.

Содержание Measurement Systems International MSI9750A

Страница 1: ...MSI9750A RF Remote Weight Indicator Operator s Manual...

Страница 2: ...Page 2 MSI 9750A RF Remote Indicator User Guide 9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE T h i s P a g e I n t e n t i o n a l l y L e f t B l a n k...

Страница 3: ...hannel Display Setup Menu 47 Custom Multi channel Display Setup Menu 48 SECTION 8 SET POINTS 49 Introduction 49 Set Point Setup Menu 50 Program Set Point Menu 51 9750A Response Menu 52 Set Point Formu...

Страница 4: ...can read the output of many CellScales and 1 CellScale can also provide data to many 9750 s The backlit alphanumeric graphic display provides precise unambiguous indication of operating modes such as...

Страница 5: ...ple channel display highlight the desired channel using the numeric keys then press DISPLAY to bring up the large display This selected channel is the Active channel to which all subsequent actions wi...

Страница 6: ...indicate a total weight GRS Abbreviation for Gross Weight Low Battery Symbol Appears when approximately 10 of battery life remains The 9750A places the indicator Low Battery Symbol Appears when appro...

Страница 7: ...will show you the current selection for each key When you change the function the previous menu changes to re ect your choice 4 If a function key does not work it is probably because the CellScale is...

Страница 8: ...eight data can be printed in any desired way The customer can add any alpha characters and or printer formatting commands including for matting for Bar Code printers Bar Code readers can also be attac...

Страница 9: ...icator for CellScales Capable of control and calibration 5 Model 9750A Portable remote indicator for CellScales Capable of control and calibration Can display multiple channels 6 Model 9300 CellScale...

Страница 10: ...ter The maximum drain on the power source is 20 watts but this amount of drain is brief The source current tapers down as the battery charges For 12V systems the maximum drain is about 1 5 amps A 5A f...

Страница 11: ...be required to correct the interference at their expense NETWORK DESCRIPTION The CellScale system uses frequency hopping which is produced by transmitting the data signal as usual but varying the carr...

Страница 12: ...om 5 default to 251 This number is usually 5 3 MY ADDRESS Any 9750A unit in a given Network must have a unique ID number Enter up to three digits to designate the 9750A ID number Ranges from 5 to 251...

Страница 13: ...DO NOT change this number from 0 unless all modem elements are also changed as this will cause severe com munications problems 2 802 11 Avoidance The 9750As modem can be set to minimize interference...

Страница 14: ...0 Select Timeout 5 The Timeout period is the time the 9750A will wait before reporting loss of updated data from the Master When the timeout period is completed without new data transmitted the weight...

Страница 15: ...e antenna should be at least 4 inches away from large metal or concrete surfaces Mounting the antenna too close to a wall has the effect of making the Antenna directional and can attenuate the output...

Страница 16: ...be sure to run the site test with the CellScale in typical locations used in your application 4 Cancel the RF Site Test by pressing the function key again If needed for some other function reprogram...

Страница 17: ...rovides channel 5 for slave CellScales and channel 6 for math channels Math Channels allow the user to add or subtract channels from each other or perform other mathematical manipulations of the data...

Страница 18: ...hannel information 1 4 JKL 2 F2 CHANNEL To Change the Scale Channel Using Scan List Position Single Channel Display Uses the CellScale s Scan List Index Number to determine which channel to display To...

Страница 19: ...annel pro cedures as desired To Delete the Current Page 1 Press the 0 SPACE key 2 Press the ALPHA key The current page will be deleted and the display will revert to the rst page The 9750A will not al...

Страница 20: ...emporarily reads TARING Then the scale returns to the GROSS mode To Keyboard Tare Tare Rules for Use 1 Only positive gross weight readings can be tared Weight can be tared in both the NET and GROSS mo...

Страница 21: ...car rier or pallet is used but multiple ID Codes are necessary for data collection To select Universal Tare choose Same Tare All ID s on the TARE SETUP MENU This effects all IDs on any given scale ch...

Страница 22: ...sly recorded is detected To Clear Peak Weight Readings Turn off the Peak mode by pressing the FUNCTION key programmed as Toggle Peak Hold The display reverts to Gross or Net and clears the peak value...

Страница 23: ...Send Message All 3 Send Message to 3 4 Send Message to 4 5 Send Message to 5 6 Reply Last Message CHANGE F4 TO 1 Enable Set Points 2 Disable Set Points 3 Enable Disable SP s 4 Set Pt Momentary 5 Set P...

Страница 24: ...t off Toggle Peak Hold Captures maximum readings Toggles on and off 2 Channel ID and Address Group Enter ID String 1 Allows direct entry of ID String 1 which can be used for any text entries Enter ID...

Страница 25: ...ive data from the Comm Port Get BarCode 4 Opens Bar Code 4 s input entry buffer to receive data from the Comm Port Get All BarCodes Programs key to open all enabled bar code buffers in order All bar c...

Страница 26: ...tion the text entry screen allows you to preprogram what type of data numeric upper case alpha or lower case alpha the string will default to what font size small medium or large and the screen format...

Страница 27: ...ET weight computation If the name did not already exist the CellScale creates a new ID Code ID Codes are alphabetized when created using the standard ASCII convention The 9750Auses the ID function key...

Страница 28: ...ID Calls a text enter screen for creating a new ID Use the alphanumeric keypad to enter any name up to 8 characters See General Text Entry for further information for text entry 2 ID Units Pressing 2...

Страница 29: ...oduct ID Codes 5 2 Select New Product ID 1 This brings up a text entry screen 3 Using the numeric keypad enter a name of an existing ID Code Use the ALPHA key to select letters as required If the Cell...

Страница 30: ...strings the ID strings can be used to design a very sophisticated bar code label with three elds that change with every ID Code the ID Code Name and ID String 1 and 2 The Function keys can be program...

Страница 31: ...d added when the weight returns below the Total Threshold The last settled reading is what will be used for totaling when the scale returns below the Total Threshold The user must make sure that while...

Страница 32: ...on Check ON 3 High Threshold 11 4 Low Threshold 10 HIGH TOTAL THRESHOLD ESC exits no change ENTER saves value 0 9 replaces value 1 min 1 max 100 incs v decs value LOW TOTAL THRESHOLD ESC exits no chan...

Страница 33: ...ead of UNITS In any View Total screen you can change channels by pressing the CHANNEL key You can change to the next ID by pressing the ID key To Display the Current ID s Totaled Weight and Statistics...

Страница 34: ...de independently The number of samples that statistics can be calculated for is limited only by memory requirements and will vary from a few thousand to 100000 samples Individual samples are not store...

Страница 35: ...d Statistics display return to the Total display by pressing ESC or return to the standard weight display by pressing DISPLAY 4 To return to the standard weight display press DISPLAY ID Name ID X X NE...

Страница 36: ...volume heard when pressing keys with keypad numbers 1 quiet through 0 loud To turn off the key tones press CLR 2 Alarm Volume is X Change the volume heard when a set point is triggered Also used for...

Страница 37: ...tus from LOCKED to UNLOCKED to LOCK ON PWR The LOCK ON PWR mode leaves the 9750A unlocked until the power has been cycled This allows the primary operator to complete all setups without having to ente...

Страница 38: ...channels the display can be set up to show up to eight channels at once Preview Screens When setting up Weight Displays the 9750A shows a preview of how the screen will be formatted Abbrevia tions for...

Страница 39: ...ode number Line 6 the total weight and the Network Address Line 7 shows the number of samples in the Total and the channel number Line 8 the Date and Time When entering numbers the Time display will b...

Страница 40: ...4 follow the same format 2 Ch 2 med data This display shows two channels along with each channels 8 character ID Name and 20 character ID String 1 Lines 1 2 SLI 1 Current Weight preceded by the scan l...

Страница 41: ...y screen to set number of displayed channels Number entry screen to set Shows preview of display DateTime Enter Num DateTime Enter Num If less than 4 Channels If less than 8 Channels 1S 1 s Weight 2S...

Страница 42: ...ISPLAY key to go directly to the selected weight display If not press ESC and repeat steps 3 to 5 To Set the Multi Channel Display Mode Using Presets To Modify the Channel Arrangement Since the preset...

Страница 43: ...me N A 16 16 Shows the Date and Time When in the form DateTimeEnter DateTime N A 16 16 Shows the Date and Time When in the form DateTimeEnter Number it may be overwritten when entering a number with t...

Страница 44: ...large font 2 rows of 8 charac ters The full ASCII character set is supported in the large font Weight displays in the large font add special characters for mode units COZ and motion All other types o...

Страница 45: ...1 is already occupied by a large font eld and is not available Pressing CLR will erase whatever is in the location but it will erase 4 lines since the large font data occupies 4 lines To identify wha...

Страница 46: ...illustrates a 14 character gross weight on a small font line and it starts at column 6 If the line you are setting up is a small font line the start column will range from 1 to 6 In the medium font t...

Страница 47: ...BACK 1 3 1 Barcode 4 2 Start Column 3 Fixed Text 4 Start Column 7 MORE 8 BACK 3 3 LARGE FONT SETUP 1 Row 1 4 8 Chars 2 Row 3 6 3 Row 5 8 4 Preview MEDIUM FONT SETUP 1 Row 1 2 16 Chars 2 Row 3 4 3 Row...

Страница 48: ...for selected Channel Clears current display settings for selected Channel Clears current display settings MULTI CH DISP MODE 0 Number of Chans X 1 3 Ch 1 lg 2 sm 2 2 Ch 2 med data 3 4 Ch 4 sm data 4 4...

Страница 49: ...the Network These Set Point actions are stored only in the 9750A and must be programmed inde pendently in all 9750 s used in the system Parameters stored in the CellScale All parameters related to th...

Страница 50: ...latched on is cleared with this selection However if the tripped condition still exists the set point will remain on and latched SET POINT SETUP MENU There are three ways to program values operators...

Страница 51: ...nse This menu item sets the response modes of the 9750A The submenus are detailed on the next page 3 Input Source Input the scan channel index number 1 32 for the scale input or math channel this set...

Страница 52: ...hes reverse characters until the message is acknowledged The Large display 2 replaces the entire display with up to 16 characters The Medium display 3 replaces the bottom 2 lines with up to 16 charact...

Страница 53: ...ntry screen allowing the set point value entry Press the Alpha key first to enter a negative number 3 Val 1 Type This menu determines the weight type the set point will use in compare Use Gross 1 for...

Страница 54: ...lines do not need to be connected Bar Code enabled 9750A have 6 9 Volts DC on pin 9 This voltage will not harm any standard PC ports but its effect on the RI line MATING CABLE The 9750A uses a standa...

Страница 55: ...more information on Set Point messages and other types of remotely gener ated messaging There is also a special print mode used with the VIEW key Pressing VIEW F Key programmed for View Total followed...

Страница 56: ...L SETTINGS DATA LOGGING COMM PORT 2 SETUP SELECT MENU INTERVAL MILLISECONDS BAUD RATE HANDSHAKING MODE AUTO PRINT TO MEMORY SETUP SELECT MENU ESC SETUP IN F3 SEND PRINT for software handshaking common...

Страница 57: ...ccess to characters above 127 decimal Characters from 128d to 255d are used for special characters and graphics by many printers Note that outputting characters above 127d requires that the serial set...

Страница 58: ...ncel 7 MORE 8 BACK 4 6 CONTROL CHARACTERS 1 EM End of Medium 2 SUB Substitute 3 ESC Escape 4 FS File Separator 5 GS Group Separator 6 RS Record Separator 7 MORE 8 BACK 5 6 CONTROL CHARACTERS 1 US Unit...

Страница 59: ...er a Star Micronics DP8340 and are used for example only Non printing control characters e g ESC CR LF DC4 etc are represented by a dot pattern in the smaller font sizes The necessary string will be S...

Страница 60: ...Use the LEFT 3 RIGHT 4 UP 5 and DOWN 6 Scroll keys to move around in the print string Change the cursor into a highlighted character by pressing the INS key The ashing digit indicates the edit able c...

Страница 61: ...to this Channel Description Cmd Command Suf x Input examples Output examples comments a space or place holder Output an sign The CellScale uses the sign for speci c embedded commands this command all...

Страница 62: ...ther Do not embed a print string inside itself Output Weight Value only V 1 current weight 2 gross 3 net 4 tare 5 total 6 of totals 7 total of totals 8 reserved 9 last totaled weight of capacity V1 V2...

Страница 63: ...ard Deviation 5 Coeff of Variance 6 Grand Total 7 Grand Average 8 of Grand Totals Output a statistics value and mode Y Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 13 350 LB AVG 3 200 LB MIN 16 650 LB MAX 2 392 LB STDDEV...

Страница 64: ...e weight data with text or V to produce the weight numeric value only If more than 1 channel of data is required use the command preceding the weight value type See Section 9 for details on string des...

Страница 65: ...EMORY 1 Print to Memory 1 2 Print to Memory 2 3 Auto Log Msg ON 4 Auto Clr IDStr1 OFF 5 Auto Clr IDStr2 OFF 6 Bar1 OFF 8 Bar3 OFF 7 Bar2 OFF 9 Bar4 OFF AUTO PRINT TO MEMORY DATA LOGGING 7 STU ESC SETU...

Страница 66: ...font 8 rows by 20 characters Words that cross line boundries will be split In order for a host to send a message to an individual 9750A the host must know the address of the 9750A The string required...

Страница 67: ...and can send to the last host that it received a message from More than 1 Function key can be designated for messages and the user can choose to send to a speci c CellScale RF or direct port or set it...

Страница 68: ...Page 68 MSI 9750A RF Remote Indicator User Guide 9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE T h i s P a g e I n t e n t i o n a l l y L e f t B l a n k...

Страница 69: ...data Power is supplied on pin 9 of the serial connector The 9750A supplies a variable voltage output of 6 to 9 volts that is the switched output of the battery Therefore a suitable bar code scanner mu...

Страница 70: ...omm Port 7 No action the Bar Code data is stored in the Bar Code 1 buffer and is available for inclusion in print strings or sent to the display 2 4 BarCode 2 4 Same options as above 5 User String 1 T...

Страница 71: ...t ing as part of the Scan List ifACTIVE If set INACTIVE the channel will not be available to any device in the Network and will not be displayed on the 9750A 2 Filter Each A D channel has independent...

Страница 72: ...ase the switch button in the hole The CellScale will acknowledge the press button by ashing its LEDs 3 Now you can proceed with calibration and calibration settings TO CALIBRATE Use this Calibration p...

Страница 73: ...SEALSWITCH ON CELLSCALE TO CONTINUE If Disabled Sealed ESC SETUP F2 CHANNEL 1 ABC 7 STU F2 CHANNEL ZERO CLR 0 ENTER 4 JKL 10 SPAN CALIBRATION 1 The CellScale transmits back the capacity as a possible...

Страница 74: ...lue 6 Press DISPLAY to return to the Scale Display Press ESC to return to the CHANNEL CALIBRATION menu MOTION BAND The motion band determines the range of weight variation that the indicator considers...

Страница 75: ...s or affect any connected CellScales To Completely Reset the 9750A To return to the To return to the T startup screen To return to the To return to the T weight display To Clear To Clear T All Setups...

Страница 76: ...pear on the 9750A and the Bootloader menu will appear on the terminal screen MSI Boot Loader Version 3 K3 1 Update Application 2 Change Baud Rate ESC Start Application Enter Command 8 Choosing a faste...

Страница 77: ...umber to the left of the screen is the upload sector value xxxx Send Upload the le During Bootloading the 9750A will display this screen When the upload is complete the following will appear in the PC...

Страница 78: ...t pin 9 which is connected to the battery is not cross connected Remove any con nection on pin 9 Source Code version must be the same in both units If not update the source code rst 1 Disable any Auto...

Страница 79: ...verride OFF 4 Lock Override ON See General Text Editing Procedure ESC SETUP SETUP SELECT MENU 1 Channel Calibrate 2 Display 3 RF Modem 4 Comm 2 Strings 5 Product ID Codes 6 Tare 7 MORE 2 2 SETUP SELEC...

Страница 80: ...d 2 Default 3 Disp Date Time 4 View Totals 5 Display Set Points 6 Clear Latched SP s 7 Toggle Peak Hold CHANGE F4 TO 1 Enter ID String 1 2 Enter ID String 2 3 New Product ID 4 Show Last Channel 5 Show...

Страница 81: ...4 SP1 And SP2 5 SP1 Or SP2 6 MORE 2 2 TRIGGER PRINT ON Current Mode 1 Continuously 2 Send Print Key 3 Comm 2 CTS 4 Weight Change 5 Stable Load 6 MORE 1 2 COMM 1 STRINGS 1 Data Out String 2 End of Line...

Страница 82: ...ORM 5 Display Mode 5 Display Mode OFF SETUP SELECT MENU SETUP SELECT MENU PRODUCT ID Chan X X ZERO CLR 0 ZERO CLR 0 ESC SETUP ESC SETUP ID F6 PRODUCT ID CODES SETUP SELECT MENU 1 Function Keys 2 Set P...

Страница 83: ...ORK ESC exits no change ENTER saves value 0 9 replaces value 1 min 1 max 1800 incs v decs value 4 Transmit Power HI 4 Transmit Power MED Saves Settings to Memory Shortcut 4 Transmit Power LO MODEM SET...

Страница 84: ...ht 7SL 7 s Weight 8SL 8 s Weight See Custom Display Menus Number entry screen to set number of displayed channels Number entry screen to set number of displayed channels Number entry screen to set Sho...

Страница 85: ...lumn 5 Net Address 6 Start Column 7 MORE 8 BACK 1 3 1 Barcode 4 2 Start Column 3 Fixed Text 4 Start Column 7 MORE 8 BACK 3 3 LARGE FONT SETUP 1 Row 1 4 8 Chars 2 Row 3 6 3 Row 5 8 4 Preview MEDIUM FON...

Страница 86: ...CLR All Clears current display settings for selected Channel Clears current display settings for selected Channel Clears current display settings MULTI CH DISP MODE 0 Number of Chans X 1 3 Ch 1 lg 2 s...

Страница 87: ...NDARD 1 Industrial unreg 2 NIST NTEP 3 OIML R76 4 Industrial Metric 4 AutoZero AZM OFF 4 AutoZero AZM ON AUTOZERO BAND d ESC exits no change ENTER saves value 0 9 replaces value 10 min 0 max 255 incs...

Страница 88: ...e 1 24V Temperature is 33 C Shortcut to Battery Monitor KEYPRESS VOLUME 1 1 z 2 n 3 nz 4 nn 8 nnnn 5 nnz 9 nnnnz 6 nnn 0 nnnnn 7 nnnz CLR Off ALARM VOLUME 8 1 z 2 n 3 nz 4 nn 8 nnnn 5 nnz 9 nnnnz 6 nn...

Страница 89: ...e press ENTER to Cal ESCape to end Cal SPAN CALIBRATION 2 Scale XXXXXXX Cal Wt 2 XXXXXXX 0 9 New Cal Weight When loaded stable press ENTER to Cal ESCape to end Cal RESETING CALIBRATION Up to 9 Span Po...

Страница 90: ...CTERS 1 BEL Bell 2 BS Back Space 3 HT Horizontal Tab 4 LF Line Feed 5 VT Vertical Tab 6 FF Form Feed 7 MORE 8 BACK 2 6 CONTROL CHARACTERS 1 CR Carriage Return 2 SO Shift Out 3 SI Shift In 4 DLE Data L...

Страница 91: ...lue 1 min 1 max 32 incs v decs value SET POINT DELAY ms ESC exits no change ENTER saves value 0 9 replaces value 1000 min 0 max 10000 incs v decs value SET POINT XX 1 Audible Alarms OFF 2 Alarm Displa...

Страница 92: ...Page 92 MSI 9750A RF Remote Indicator User Guide 9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE APPENDIX B ASCII CHART...

Страница 93: ...printers scoreboards and most serial devices Send Print Output user con gured print strings to Comm Ports or via RF to any connected host Manual or Automatic Data Logging Up to 128 kbytes of storage a...

Страница 94: ...y freight pre paid In no event shall the Company be liable for the cost of any repairs or alterations made by others except those repairs or alterations made with its speci c written consent nor shall...

Страница 95: ...EIGHING SYSTEMS COMPANY Measurement Systems International TM 14240 Interurban Avenue South Suite 200 Seattle WA 98168 4661 USA Phone 206 433 0199 Fax 206 244 8470 www msiscales com 2012 Rice Lake Weig...

Отзывы: