MSI CellScale
®
System • 9750A User Guide Page 5
MEASUREMENT SYSTEMS INTERNATIONAL
Firmware Version 5-XX for 2450 Modems
KEY DESCRIPTIONS
The
POWER
key turns the 9750A On and Off. The
POWER
key must be held for 1 second to ensure startup.
The
ZERO
key is used to zero out residual weight on the scale. When entering numbers or strings the
ZERO
key is used
to Clear (delete) characters.
The
TARE
key is used to zero out the weight of containers, trucks, or carriers and to place the scale in the Net weight
mode.
The
NET/GROSS
key allows the operator to alternate the weight display from Net (Tared) weight to Gross weight. In
some Legal-for-trade jurisdictions, the Gross weight display is limited to 3 seconds.
The
SETUP
key allows entry into the setup submenus. Use this to fi nd menus for setting the Date and Time, setting up
the function keys, controlling the display mode and backlight, password locks, calibration, etc.. The key is also used for
ESC
ape. Use
ESC
to return to the previous menu, or display mode.
The
ENTER
key fi nalizes the entry of numeric or alphanumeric text entries. It also provides an alternate way to maneu-
ver through menus combined with the cursor keys. Pressing
ENTER
before certain keys takes you directly into various
modes. Pressing
ENTER
before a Function key enacts the alternate Function key mode.
The
ALPHA
key is used during text entries to select upper case, lower case or numbers. Sometimes used for negative.
The numeric keypad provides all numerals and letters for data entry. Submenus provide punctuation and control charac-
ters.
The
DISPLAY
key is used to alternate between single channel displays and multiple channel displays. While in the
multiple channel display, highlight the desired channel using the numeric keys, then press DISPLAY to bring up the
large display. This selected channel is the “Active” channel to which all subsequent actions will be applied. Provides
the decimal point or period in numeric and text entries. Functions as EXIT in menus returning directly to weight display
without having to back through all previous menus.
F1 defaults to
TOTAL
. Pressing this key will cause the current weighment to be added to the total register. In Auto-Total
modes, the
TOTAL
key turns Auto-total off and on. Up Cursor in menus.
F2 defaults to
CHANNEL
. When the CellScale has more than 1 channel defi ned in its Scan List, the
CHANNEL
key
will select the next active channel in the list. Precede the
CHANNEL
key with a numeric entry (1-32) to switch directly
to a channel scan list position. Press
SETUP CHANNEL
for a shortcut to the “Channel Setup Menu”. Left Cursor in
menus.
F3 defaults to
SEND/PRINT
. The action of this key is dictated by the Function key menu, but is usually used to send
data to the CellScale or one of its hosts. Used for Insert in text and number entry screens.
F4 defaults to
ADDRESS
. The
ADDRESS
key is used to log on to other CellScale Networks. Pressing the
ADDRESS
key alone will change the active network to the next defi ned Network. Preceding the
ADDRESS
key with a Network
number (0-31) will cause the 9750A to log directly on the entered Network, if it exists and is active.
F5 defaults to
UNITS
. Pressing this key will change the operational units (if enabled) of the current focus channel.
F6 defaults to
ID
. Pressing
ID
will change you to the next defi ned ID. Right Cursor in menus.
POWER
ZERO
CLR
0
TARE
TT
T
NET/GROSS
B/G
ESC
!
SETUP
ENTER
ALPHA
A
a
1
1
ABC
F1
TOTAL
F2
CHANNEL
F4
ADDRESS
DISPLAY
EXIT
IN
F3
SEND/PRINT
UNITS
F5
ID
F6
9
@YZ
8
VWX
7
STU
6
PQR
5
MNO
4
JKL
3
GHI
2
DEF
0
SPACE