background image

Appendix

39

6.3

Specifications

Unit

Item

Description

Weighing Unit

Weighing Capacity

30 lb specification: 0 to 15 lb/.02 lb, 15-30 lb/.05 lb

Weighing Accuracy

1/3000

Operation Panel Unit

Display Method

L1: 23-digit 16 segment LCD
L2: 192 x 16 dot matrix/23-digit 7 segment LCD

Customer Display Unit

Display Method

L1: 23-digit 16 segment LCD
L2: 192 x 16 dot matrix/23-digit 7 segment LCD

Printer Unit

Printing Method

Direct thermal method

Thermal Head

2 inches (448 dots) and 8 dots/mm

Printing Speed

100 mm/second
The printing speed may vary depending on the label 
conditions

Printing Effective Size

56 mm in width

Label Roll Size

Label Width: 38 to 68 mm
Label Length: 30 to 175 mm

Label Roll Size

Roll Outside Diameter

100 mm max

Paper Core Inside Diameter

40 mm ±1 mm

Others

Power Supply

100 to 240 VAC, 50/60 Hz

Use Conditions

Temperature: 23 to 104°F
                    -5 to 40°C

Input/Output

LAN: 1 channel
USB: 1 channel
RS-232C: 1 channel

Table 6-3. Uni-3 Specifications

Содержание ISHIDA Uni-3

Страница 1: ...Ishida Uni 3 Price Computing Scale With Printer Operation Manual PN 166737 Rev A...

Страница 2: ......

Страница 3: ...3 1 P01 PLU Data 16 3 2 P02 Campaign 19 3 3 P03 Operators 19 3 4 P04 Preset Key Registration 20 3 5 P05 Ad Message 22 3 6 P06 Store Data 22 3 7 P07 Department 22 3 8 P08 Group 23 3 9 P09 Cooking Time...

Страница 4: ...31 4 3 1 F05 Daily Totals 31 4 3 2 F06 Weekly Totals 31 4 3 3 F07 Cumulative Totals 32 4 3 4 F09 Preset Report 32 4 3 5 F12 Total Clear 32 5 0 Maintenance 33 5 1 Level Adjustment 33 5 2 Label Receipt...

Страница 5: ...ults from incorrect operation insufficient caution unauthorized modifications to the scale or failure to follow the instructions contained in this manual Contact any Rice Lake Weighing Systems dealer...

Страница 6: ...t display Used to call a registered product data Used to move left Used to feed labels Used to move right Used to issue a label Used to move up Used to enter tare weight Used to move down Used to rese...

Страница 7: ...the desired choice Setup 6000 Adjustment 4000 Program 9000 Operation 2000 Total 8000 Machine No Date Time PLU Sales Sales Daily Total Sales Mode Display Check Campaign Total Adjust Sales Weekly Total...

Страница 8: ...ter to enter B02 01 SALES MODE 3 Press the Right arrow to view the available options from 1 NO OPERATOR to 6 CR FIXED OPERATOR 4 To change the current setting press the appropriate numeric key Example...

Страница 9: ...mode for fixed operator Table 2 2 B02 Sales Mode Parameters Parameter Display Description Choices B03 01 Password PASSWORD 000000 ZERO Specify the password that will be used for all the items listed i...

Страница 10: ...O PRINT 2 PRINT B06 01 02 P D T HOUR Product Daily Total Hour B06 01 03 P D T DEPT Product Daily Total Department B06 01 04 P D T GROUP Product Daily Total Group B06 01 05 P D T OPER Product Daily Tot...

Страница 11: ...rice ABC B06 03 08 PLU ABC 3 Product Cumulative Total Weight ABC B06 03 09 PLU ABC 4 Product Cumulative Total Pieces ABC B06 03 10 PLU Z 2 Product Cumulative Total Price Z B06 03 11 PLU Z 3 Product Cu...

Страница 12: ...ate or sell by time change is saved B07 08 Tare Select if a tare weight change is saved B07 09 B07 11 Extra Message 1 3 Select if a different extra message is linked to the PLU B07 13 Coupon Message S...

Страница 13: ...01 01 Sales Mode is set to 1 Fix Price 0 999 B08 01 10 Tare Weight Enter tare weight Press Enter 0 000 9 990 lb B08 01 14 Lower Weight Enter the lower weight limit Press Enter 0 000 30 000 lb B08 01 1...

Страница 14: ...06 04 Sell By Date Print Enter the mode number Press Enter to select whether or not to print the sell by date 1 YES 2 NO B08 06 05 Sell By Time Print Enter the mode number Press Enter to select the de...

Страница 15: ...W5d 9 F1C5I6d 10 F2C6P4d 11 F2C6W4d 12 F2C4wW5d 15 F2C50P4d 16 F2C5W5d 17 F2C5P5 10d 18 F2C5pP4 10d 19 F2C5wW4d 20 F1C5P6d 21 F2C4P6d 22 F1C3W4P4d 23 F2C4Q2P4d 24 F1I6P5d 25 F2I6P4d 26 F1C4P7d 27 F1I6...

Страница 16: ...EXCLUDED 2 INCLUDED 3 EXEMPT B29 00 TAX0 Rate Tax Rate 0 99 99 B29 01 TAX1 Type Tax Type 1 EXCLUDED 2 INCLUDED 3 EXEMPT B29 01 TAX1 Rate Tax Rate 0 99 99 B29 02 TAX2 Type Tax Type 1 EXCLUDED 2 INCLUD...

Страница 17: ...keys or key in the corresponding number and press the Up or Down arrow to select the appropriate choice Example 1 From the Adjustment mode main menu screen press the down arrow once to scroll to C01 D...

Страница 18: ...our Minute Second Press Enter to store the data HHMMSS C01 03 Local Year Set the year in four digits C01 04 Julian Date The Julian date is the number of days since January 1st This step displays the J...

Страница 19: ...ess the desired preset key again to register the function 7 Press Mode to exit POO PROGRAM 322 352 5 0 1 P01 PLU 2 P02 Campaign 3 P03 Operator Data 4 P04 Preset Key 5 P05 AD MSG 6 P06 Store Data 7 P07...

Страница 20: ...to select whether or not to allow an open price system 0 YES 1 NO P01 01 04 Unit Price Enter the unit or fixed price Press Enter P01 01 08 Tax Enter a numeric value Press Enter P01 01 10 Tare Weight E...

Страница 21: ...lect whether or not to print the first label 1 YES 2 NO P01 05 05 2nd Label Print Enter the mode number Press Enter to select whether or not to print the second label 1 YES 2 NO P01 06 Date P01 06 01...

Страница 22: ...FER 1 EAN UPC 13 2 EAN UPC 8 3 10 DIGITS 13 4 5 DIGITS 8 5 GS1 6 GS1 ST 7 GS1 STO 9 GS1 EXP 10 ITF P01 07 07 POS Format WGT This field is only available when one PLU file is selected in POS Reference...

Страница 23: ...our format Press Enter P02 02 Data P02 02 01 Call PLU Enter desired PLU number and press PLU P02 02 02 PLU Name and Number Displays the PLU name and number for confirmation P02 02 03 MD Mode Enter the...

Страница 24: ...oupon Message 15 Subtotal Display Subtotal Display 16 Extra1 Extra Message 1 17 Extra2 Extra Message 2 18 Extra3 Extra Message 3 20 SP U P Special unit price 22 Format Change of label format 23 Image...

Страница 25: ...101 Charge Add cost to subtotal in 102 Data distribution Distribution of master data 103 Price subtot Price subtotal 104 Subtot subtotal 105 Preset Price Subtot Price subtotal by preset 106 Preset Su...

Страница 26: ...ge Table 3 6 P05 Ad Message Display Description Choices P06 00 Store No Enter the store number and press PLU to display the desired store data 13001 0000 Set Up New Data If a non registered item has b...

Страница 27: ...ew data or Clear to go back P09 00 Method Press Edit to edit the cooking method Press Enter when editing is complete InP 0001 0000 The Text Edit screen is displayed for the selected store number Edit...

Страница 28: ...Percent Enter the protein percent P10 22 Sugars Enter the sugar value g P10 23 Sugars Pecent Enter the sugar percent P10 24 Vitamin A Percent Enter the vitamin A percent P10 25 Vitamin C Percent Ente...

Страница 29: ...Data If a non registered item has been requested the confirmation screen is displayed Press Enter to set up new data or Clear to go back InP 0001 0000 The Text Edit screen is displayed for the selecte...

Страница 30: ...ber and press PLU to display desired free message data 13001 0000 Set Up New Data If a non registered item has been requested the confirmation screen is displayed Press Enter to set up new data or Cle...

Страница 31: ...rom the initial screen enter 2000 using the numeric keypad 2 Press Mode 3 The Operation Mode screen displays 4 Press Mode to exit the Operation Mode 4 2 1 Issuing Labels 1 Ensure that the initial scre...

Страница 32: ...roduct on the weighing platter 5 Press Receipt Subtotal to complete the registration 6 The subtotal screen for the designated operator is displayed 7 Press Mode to return 8 Enter the PLU number Exampl...

Страница 33: ...Press an operator key Example Operator JACK 14 The subtotal screen for the designated operator is displayed 15 The operator is returned to BETTY 16 Press Mode to return and enter the PLU number 17 The...

Страница 34: ...ng Prices By Amount Enter the amount to be discounted and press the U P key Example Discount amount of 0 50 Discounting Prices by Percentage Enter the discount percentage and press the U P key Example...

Страница 35: ...epartment Press Print to print the data F05 04 Group Press Print to print the data F05 05 PLU Number Enter a desired PLU number Press Print to print data F05 06 Operator Press Print to print the data...

Страница 36: ...ion F09 Preset Report F09 01 Preset Report F09 02 Daily Press Print to print the data F09 03 Weekly Press Print to print the data F09 04 Cumulative Press Print to print the data Table 4 4 F09 Preset R...

Страница 37: ...off before moving or adjusting the level of the scale 1 Place the machine on a stable platform 2 Adjust the inclination of the machine by turning the four level adjustment legs until the spirit bubbl...

Страница 38: ...of the main body Figure 5 2 Open the Right Cover 2 Set a new roll around the roll holder Figure 5 3 Place the New Roll on the Roll Holder 3 Raise the roll stopper to fix the roll position 4 Lift up on...

Страница 39: ...eed to issue a label At this time confirm that the label is completely peeled off Confirm that the backing paper is wound up smoothly If the backing paper is wound up diagonally check that the label i...

Страница 40: ...Operation Manual 5 4 Cleaning the Machine 1 Lift up on lever on thermal head to unlock Figure 5 8 Unlock the Thermal Head 2 Use a cotton tipped swab to clean off the thermal head Figure 5 9 Clean Ther...

Страница 41: ...tore number program if necessary 221 Tare Limit Over g Re program tare weight 222 Tare Weight is 0 g Set tare weight 223 Label Setting Master Is Not Programmed Check label number program if necessary...

Страница 42: ...5 001 Thermal Head Is Worn Out For Printer 1 Thermal head is worn but there is no effect on printing 715 002 Thermal Head Is Worn Out For Printer 1 Change thermal head 1601 Span Adjustment For Scale I...

Страница 43: ...gment LCD Printer Unit Printing Method Direct thermal method Thermal Head 2 inches 448 dots and 8 dots mm Printing Speed 100 mm second The printing speed may vary depending on the label conditions Pri...

Страница 44: ...at the nonconformity actually exists and was not caused by accident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged non...

Страница 45: ......

Страница 46: ...Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 www ricelake com www ricelake mx www ricelake eu www ricelake co in Rice Lake Weighing Systems is an ISO 9001 registered...

Отзывы: