Setup
9
2.1.7
B08-PLU Initial Data
Specify the default values for any new PLU. When a new PLU is
programmed the initial data automatically populates the fields.
This speeds up PLU programming by setting the customer’s
standard values. The initial data values can be changed as needed
during PLU programming.
Parameter
Display
Description
Choices
B08-01
Sales 1
B08-01-01 Sales Mode
Enter the mode number. Press
Enter
to select a desired
sales mode.
0: WEIGHT
1: FIX PRICE
2: WGT+F.P.
3: CASE WGT
B08-01-02 Markdown Mode
Enter the mode number. Press
Enter
to select a desired
markdown mode.
0: NORMAL
1: SPECIAL
2: -$
3: -%
4: SPEC. U/P
5: U/P -$
6: U/P -%
B08-01-03 Open Price
Enter the mode number. Press
Enter
to select whether or
not to allow an open price system.
0: YES
1: NO
B08-01-04 Unit Price
Enter the unit or fixed price. Press
Enter
.
0.00
-999.99
B08-01-05 Markdown Amount
Not available when B08-01-02 Markdown Mode is
set to 0:NORMAL.
0.0
- 99.9 (%)
0.00
- 999.99 ($)
B08-01-07 Unit Type
Only available when B08-01-01 Sales Mode is set to 1:
Fix Price or 2: WGT F/PRI.
0 -
16
B08-01-08 Tax
Enter a numeric value. Press
Enter
.
0 -
9
B08-01-09 Fixed Weight
Only available when B08-01-01 Sales Mode is set to 1:
Fix Price.
0 -
999
B08-01-10 Tare Weight
Enter tare weight. Press
Enter
.
0.000
- 9.990 (lb)
B08-01-14 Lower Weight
Enter the lower weight limit. Press
Enter
.
0.000
- 30.000 (lb)
B08-01-15 Upper Weight
Enter the upper weight limit. Press
Enter
.
0.000
- 30.000 (lb)
B08-02
Sales 2
B08-02-06 Point Flag
Enter the mode number. Press
Enter
to select whether or
not to use the point flag.
1: ON
0: OFF
B08-02-07 Point Type
Enter the mode number. Press
Enter
to select the desired
point type.
0: WGT
1: PCS
B08-02-08 Points
Enter a desired number. Press
Enter
.
0 -
99999
B08-03
Message
B08-03-01 Nutrition Panel
Nutrition facts programmed through the SLP-5 software.
0 -
999999
B08-03-02 — B08-03-4
Extra Message 1-3
Extra messages programmed in the P11 Extra Message
Program Menu.
0 -
999999
B08-03-05 Coupon Message
Coupon message programmed in the P14 Coupon
Message Program Menu.
0 -
999999
B08-03-06 POP Message
POP message programmed in the P15 POP Message
Program Menu.
0 -
999999
B08-03-07 Cook Time
Cook time programmed in the P09 Cook Time
Program Menu.
0 -
9999
B08-03-08 — B08-03-22
Free Message 1-15
Free messages programmed in the P22 Free Message
Program Menu.
0 -
999999
B08-03-23 Nutrition Text
Nutritional panel footer text programmed through the
SLP-5 software.
0 -
999999
Table 2-8. B08 PLU Initial Data Parameters
BO8 PLU INITIAL DATA
%23/8,1,7,$/'$7$
Содержание ISHIDA Uni-3