11/20/2015

PN 172726

230 W. Coleman St. • Rice Lake, WI 54868 • USA

U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • 31 (0)26 472 1319

www.ricelake.com   www.ricelake.mx   www.ricelake.eu   www.ricelake.co.in   m.ricelake.com

Rice Lake Weighing Systems is an ISO 9001 registered company. 

© Rice Lake Weighing Systems      Specifications subject to change without notice.

Содержание iDimension 100

Страница 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Страница 2: ...iDimension 100 Managers Guide PN 172726...

Страница 3: ......

Страница 4: ...s Tab 23 2 4 2 Network Security Tab 23 3 0 Calibration 24 3 1 Calibration Settings 25 3 1 1 Calibration Settings Tab 25 3 1 2 Zone of Interest Tab 27 3 2 Camera Calibration 28 3 3 Perform a Factory Ca...

Страница 5: ...System Log 45 7 4 Debug Info 45 8 0 QubeVu Inspector 46 8 1 Device Information 46 8 2 Change Log 47 8 3 Long Term Storage Log 48 8 3 1 Enabling Long Term Storage 48 8 3 2 Viewing Long term Storage Da...

Страница 6: ...l operator displays when hooked up to a network computer as well as configuration parameter settings used to adjust the device to meet the application s needs These tools are recommended for use by a...

Страница 7: ...ust be installed near the equipment and must be easily accessible Always disconnect from main power before performing any work on the device Check the power cable for damage regularly and replace it i...

Страница 8: ...1 If DHCP is preferred the network administrator can advise as to the IP address leased by the unit 1 3 2 Configure PC Network Settings 1 Connect to a computer using a standard Ethernet cable 2 Config...

Страница 9: ...ure 1 3 Status Display 1 5 1 Status Messages The device status messages that may be displayed are described below Status Description Running The iDimension 100 is running in normal operations mode Sta...

Страница 10: ...he status will change to Configuring until a Save or Reboot action is completed Allow the status to return to Running before exiting from the QubeVu Manager Cancel The Cancel button will cancel all ch...

Страница 11: ...er displays use the following steps 1 Go to the QubeVu Manager home page 2 Select Displays 3 Select the desired display operator customer or demo Figure 1 6 Displays Menu 1 6 1 Operator Display The Op...

Страница 12: ...hat there is either not an item in the viewable area or that the item is too large If only one arrow is lit it indicates the direction the item is out of bounds An item cannot be dimensioned unless it...

Страница 13: ...Height process Refer to the iDimension 100 Assembly Guide for detailed information Restart prompts the operator to either confirm a restart of the device or to cancel IP Address displays the IP Addre...

Страница 14: ...ay Indicator Name Description Regular Shape Indicator This symbol indicates the item was treated as a regular shape Irregular Shape indicator This symbol indicates the item was treated as an irregular...

Страница 15: ...pture Definitions Section 4 0 on page 34 Firmware Upgrade Section 5 0 on page 37 Backup Section 6 0 on page 40 Diagnostics Section 7 0 on page 42 To enter the Admin Tools menu use the following steps...

Страница 16: ...wing steps to enter the Setup Menu 1 Go to the QubeVu Manager home page 2 Select Admin Tools to log in The Administrator defined a username and password during the initial setup process The username a...

Страница 17: ...General Settings From the Setup menu select General Settings Figure 2 2 QubeVu Manager Setup Main Menu General Settings Choose the General Settings or the Date Time tab from the General Settings menu...

Страница 18: ...Threshold When switched On the capture process will be initiated as soon as a parcel item is placed in the Zone of Interest the item is stable no movement is detected by the iDimension 100 and if a s...

Страница 19: ...response from the scale Default 3000 Valid Values scale dependent Low Resolution Camera The Switch resolution delay parameter specifies the minimum period of time in milliseconds the system should pa...

Страница 20: ...f 2 1 2 Date Time Tab The iDimension 100 s date and time settings can be changed through the Date Time tab The date and time are used to time stamp configuration changes that affect the Legal for Trad...

Страница 21: ...s to the Measurement Settings will invalidate the Legal for Trade certification Only change these settings if Legal for Trade certification is not required From the Setup menu select Measurement Setti...

Страница 22: ...6 mm to 77 mm Zero Height Max Change in The maximum allowable change in height for the zero height operation Default 6 inches Valid Values Any value greater than 0 in Target Finder Image File This par...

Страница 23: ...ge gradient must be above this value in order for the local feature to be considered as an edge Default 30 Valid Values 0 to 100 Table 2 6 Item Tracking Parameters Parameters Description Values Track...

Страница 24: ...en the device head and the object it is measuring Default Value 27 6 in Valid Values 23 6 in to 70 9 in or Depth max value Depth Max in This parameter is the threshold depth value above which any dept...

Страница 25: ...on 100 will be restarted after the restore If parallax settings were also selected and deleted the cameras must be re calibrated before the iDimension 100 will be ready for use Use the Restore action...

Страница 26: ...ength 6 characters Maximum length 511 characters All printable characters are allowed except Unicode characters Changes in case only are not valid i e password to PASSWORD The new password must not be...

Страница 27: ...etwork settings for the enterprise network Select Network from the Setup menu to enter the Network menu Figure 2 12 QubeVu Manager Setup Main Menu Network Use the Network Settings or Network Security...

Страница 28: ...defined This name will be used to access the device from the Manager Tools in the future A host name can be up to 15 characters Example http hostname IP Address If DHCP is checked do not enter an IP a...

Страница 29: ...d to ensure correct calibration Use the following steps to enter the Calibration Menu 1 Go to the QubeVu Manager home page See Figure 1 1 on page 3 2 Select Admin Tools to log in The Administrator def...

Страница 30: ...ion This is the motion threshold value below which the system must settle in order to lock onto an object Default 1 Valid Values 0 to 100 Motion Up A low pass filter is applied to the motion detected...

Страница 31: ...ture of new dimensions Default 3 9 in Valid Values 0 8 in to 11 8 in Diff Theta Enabled This parameter determines whether or not the system should relock based on the detection of a shift in the objec...

Страница 32: ...Calibration 2 Select Calibration Settings 3 Select the Zone of Interest tab Figure 3 5 Zone of Interest Tab 4 Press the Edit button to switch to configuration mode This may take a few minutes while th...

Страница 33: ...base plate and put the calibration object on top of the scale Center the scale using the base plate marks If not using a scale place and center the calibration object directly onto the base plate To...

Страница 34: ...the Low Resolution tab 6 Hold down the left mouse button and drag the mouse to draw a rectangle around the calibration object Figure 3 8 Camera Calibration Low Resolution Tab 7 Press Calibrate Figure...

Страница 35: ...ccessful Review each tab to ensure that the calibration object was successfully captured and no other object had mistakenly been placed in the view of the camera Figure 3 10 Calibration Successful 9 P...

Страница 36: ...teps to perform a factory calibration 1 Go to the QubeVu Manager home page 2 Select Admin Tools to log in The Administrator defined a username and password during the initial setup process The usernam...

Страница 37: ...ment Settings Main Menu 5 Select The delete the factory calibration prompt will display Figure 3 14 Delete Factory Calibration 6 Select OK to continue and delete parallax settings 7 Select The factory...

Страница 38: ...3 2 on page 28 10 Define the Work Area and Zone of Interest See the iDimension 100 Assembly Instructions manual for complete instructions on setting the Work Area and Zone of Interest 11 If using a s...

Страница 39: ...The iDimension 100 will dimension and capture the image s when it detects that an item has been placed under the scan head and there are no impeding conditions such as movement or unstable scale readi...

Страница 40: ...ition 1 Click on the drop down box to display capture definitions 2 Click on desired definition 3 Click Save Capture Definition Description autotriggerflat This capture definition is used for items wi...

Страница 41: ...lick Save Parameter Description Definition Name Enter a name to assign to this definition Low Res Camera Capture If checked the iDimension 100 will create a low resolution camera image ResX and ResY a...

Страница 42: ...e following steps to enter the Firmware Upgrade Menu 1 Go to the QubeVu Manager home page See Figure 1 1 on page 3 2 Select Admin Tools to log in The Administrator defined a username and password duri...

Страница 43: ...port of the iDimension 100 2 Select Read to read the USB drive Figure 5 3 Firmware Upgrade USB File Read 3 Select the firmware version from the USB drive 4 Click on Upload The firmware upgrade proces...

Страница 44: ...automatically restart to complete the upgrade While the iDimension 100 is restarting the QubeVu Manager user interface cannot be displayed and an error may display in the browser Close the browser win...

Страница 45: ...in The Administrator defined a username and password during the initial setup process The username and password are required to log into and access the QubeVu Manager Admin Tools 3 Select Backup Figur...

Страница 46: ...ow Figure 6 4 Backup Complete Notification 6 2 Restore The Restore function is used to restore settings from either the factory calibration file or from a saved backup file 1 Select to begin the resto...

Страница 47: ...ring the initial setup process The username and password are required to log into and access the QubeVu Manager Admin Tools 3 Select Diagnostics Figure 7 1 Admin Tools Main Menu Diagnostics The Diagno...

Страница 48: ...he status of each individual component is returned as either Passed or Failed Additional details can be viewed by clicking the button beside each component Component failures should be reported to the...

Страница 49: ...a serial scale attached to the iDimension 100 Select the Serial Port and Scale Type from the drop down lists Click to start the test Figure 7 5 Scale Test If a valid scale is detected the output will...

Страница 50: ...st Figure 7 7 System Log The log can be manually refreshed by clicking the refresh button or the log will automatically refresh by checking the auto refresh box To download the log to a CSV file click...

Страница 51: ...QubeVu Inspector menu has three tabs in which to view information Device Information Change Log Long Term Storage Log Figure 8 1 QubeVu Inspector Device Information Tab 8 1 Device Information The Devi...

Страница 52: ...of the iDimension 100 may be viewed The Change Counter displays the number of changes that have been made within the selected date range Enter a Start and End date and click If is selected without ent...

Страница 53: ...hem 8 3 1 Enabling Long Term Storage Long Term Storage is enabled from the Measurement Settings tab and by default is disabled with a zero value See Section 2 2 1 on page 16 and Figure 2 7 on page 16...

Страница 54: ...u Inspector 49 Enter a scan ID range and click Figure 8 6 Long Term Storage Data Use the scrolling buttons on the PC keyboard to scroll through the results The log can be exported to a CSV file by cli...

Страница 55: ...50 iDimension 100 Managers Guide...

Страница 56: ......

Страница 57: ...xico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 www ricelake com www ricelake mx www ricelake eu www ricelake co in m ricelake com Rice Lake Weighing Systems is an ISO 9001 regist...