Setup
19
Depth Sensor
The
Depth Sensor
parameters are described below.
Results
The
Results
parameter determines the handling of raw results.
Parameters
Description
Values
Factory Focal Length
(pixels)
This parameter is the initial focal length of the depth sensor for the
purpose of factory calibration, provided in pixels relative to its
resolution.
Default: 285 pixels
Valid Values: use default value
Focal Length (pixels)
This parameter is the focal length of the depth sensor, provided in pixels
relative to its resolution.
Default Value: 285 pixels
Valid Values: use default value
Depth Min (in)
This parameter is the threshold depth value below which any depth
measure will be ignored.
It is the minimum distance allowed between
the device head and the object it is measuring.
Default Value: 27.6 in
Valid Values: 23.6 in to 70.9 in
(or
Depth max
value)
Depth Max (in)
This parameter is the threshold depth value above which any depth
measure will be ignored. It is the maximum distance allowed between
the device head and the object it is measuring.
Default Value: 70.9 in
Valid Values: 23.6 in (or
Depth Min
value) to 70.9 in
Depth Camera
Height (in)
This parameter is the the distance between the depth sensor and the
base of the
iDimension 100
.
Default Value: 60.2 in
Valid Values: 23.6 in to70.9 in
Parallax
This is a read only field and is the correction factor compensating for
slight parallax imperfections.
N/A
Table 2-10. Depth Sensor
Parameter
Description
Values
Raw Dimension
If on, this parameter instructs the
iDimension 100
to return raw results
that have not been rounded to the nearest division.
Default: Off
Valid Values: On/Off
Table 2-11. Results
Содержание iDimension 100
Страница 2: ...iDimension 100 Managers Guide PN 172726...
Страница 3: ......
Страница 55: ...50 iDimension 100 Managers Guide...
Страница 56: ......