Indicator Setup
17
3.3
Configuration of the EL232 XPCD
To configure the EL232 XPCD, you must know the following:
•
Baud rate
•
Indicator type
•
Data format - RS232 or 20 mA current loop
Once this information is known, it is entered through SW1, the eight-position DIP switch on the upper left hand
corner of the CPU board, shown below:
Figure 3-8. RS232 XPCD CPU Board
Enter the correct values from Table 3-2.
Refer to Table 3-3 on page 18 for specific switch
settings for applicable indicators.
The power must be off when these values are changed.
If the power is on, press the
Reset
switch on the CPU
board to enter the new values (see Figure 3-9).
Figure 3-9. Reset Switch Location
J1
GND
K4
K3
K2
K1
+5V
CL4 IN-
CL4 IN+
CL3 IN-
CL3 IN+
CL2 IN-
CL2 IN+
CL1 IN-
CL1 IN+
CLO OUT
-
CLO OUT+
RS232 (-)
RS232 (+)
J2
GND
NEUTRAL
117 V
AC
SW2
OPEN
1
2
3
4
OPEN
1
2
3
4
6
7
8
5
SW1
+5
+5
MOSI
SCK
PA7/LD
GND
GND
TxD
RxD
PB
PB6
PB5
PB4
RESET
1 2 3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
MICROPROCESSOR
Baud Rate
Speed
SW1-1
SW1-2
1200
On
On
2400
Off
On
4800
On
Off
9600
Off Off
Table 3-2. Baud Rate Setting
J2
SW2
OPEN
1
2
3
4
GND
TxD
RxD
PB
PB6
PB5
PB4
RESET SWITCH