EL232 XCPD Installation Manual

 

2.2

Sealoff Fittings

 

The utmost care must be taken to completely seal the inside of the remote display off from the outside world. To
do this all wiring into and out of the enclosure must be in conduit using sealoff fittings between the remote
display and the conduit. The sealoff fittings ensure that the hazardous atmosphere does not travel either through
the conduit or through insulation or wiring back to the safe area. The graphic shown below illustrates the location
of sealoff fittings.

These fittings, once installed and sealed are very difficult to remove so make sure all the wiring has been double
checked before beginning. If rigid conduit is not being used for connection to the scale base, be sure to install an
approved strain relief fitting to avoid pulling the wires out of the sealoff fittings in an accident. Doing so would
open a flame path to the enclosure and defeat its purpose. 

 

Note:

 

 

 

The inside of an explosion proof enclosure is considered a Division II area when the enclosure has

been properly sealed.

 

 

SEAL FITTING

18" MAX.

FROM BOX

MAKE SURE THE MOUNTING SUPPORT IS CAPABLE
OF HOLDING CONDUIT TIGHT AGAINST IT. NO
STRAIN MUST BE PLACED ON THE SEALOFF
FITTING ASSEMBLY.

WHEN USING FLEXIBLE CONDUIT, USE
MULTIPLE PIPE STRAPS TO SECURE
R I G I D   C O N D U I T   T O   T H E   S U P P O R T
STRUCTURE. ATTACH THE FLEXIBLE
CONDUIT TO THE RIGID CONDUIT ONLY
AFTER MULTIPLE STRAPS HAVE BEEN
ATTACHED TO PREVENT ANY STRAIN
FROM REACHING THE SEAL-OFF FITTINGS.

CLASS I

DIVISION 2

GROUP

 C & D

CLASS II

DIVISION 1

GROUP

 E F & G

TO 

PREVENT IGNITION OF

HAZ.

 ATMOS.,

 DISCONNECT

ORE OPENING

. KEEP

CIRCUIT IS 

ALIVE

FROM SUPPL

Y BEF

ASS'Y TIGHT WHILE

CA

UTION:

REMOTE  WEIGHT DISPLAY

LBS

KGS

GROSS

NET

NO SIGNAL

MADE IN U.S.A.

Содержание EL232 XPCD

Страница 1: ...16942 EL232 XPCD Explosion Proof Remote Display Installation Manual To be the best by every measure...

Страница 2: ......

Страница 3: ...t 14 3 2 Serial Data Input 14 3 2 1 RS232 C 14 3 2 2 20 mA Active Current Loop Input 15 3 2 3 20 mA Passive Current Loop Input 16 3 3 Configuration of the EL232 XPCD 17 3 3 1 Loss of Signal Display 18...

Страница 4: ...2 ES232 XPCD Installation Manual...

Страница 5: ...in this manual Improper specification installation or service of this equipment could result in personal injury or property damage Read all of the manual prior to installation Do not assume that all h...

Страница 6: ...DOUS AREA High temperature gases Cooling from conduction of heat along the threads There must be a minimum of five full threads of engagement of a 2 A 2 B fit for a Group C enclosure Group B increases...

Страница 7: ...that enclosure s rating Explosion HAZARDOUS AREA High temperature gases Cooling from expansion of gas Boyle s Gas Law The distance from the boundary of the inside of the enclosure to the gasket is kn...

Страница 8: ...4 EL232 XPCD Installation Manual...

Страница 9: ...323 4316 Weightronix WI 110 and WI 120 Toledo indicators with High speed data format Flex weigh DWM 4 Analogic AN5315 AN5316 AN5322 Masstron M 2500 and M 5000 Fairbanks 90 164 series Streeter Richards...

Страница 10: ...display digits and five LED annunciators Figure 1 1 EL232 XPCD Front Panel CLASS I DIVISION 2 GROUP C D CLASS II DIVISION 1 GROUP E F G TO PREVENT IGNITION OF HAZ ATMOS DISCONNECT O RE O PENING KEEP...

Страница 11: ...the enclosure It is recommended to shelter the outdoor installation by a shelter roof enclosure or covering Moist environments can also be controlled by the use of desiccants Contact your local dealer...

Страница 12: ...ain relief fitting to avoid pulling the wires out of the sealoff fittings in an accident Doing so would open a flame path to the enclosure and defeat its purpose Note The inside of an explosion proof...

Страница 13: ...he explosion proof enclosure is allowed to vent internal pressure appropriately the outer insulation must be removed back to the point ahead of entry into the safe area Multi conductor cables will pas...

Страница 14: ...amp with a blunt stick to expel any air bubbles Install and tighten filling opening cover Fittings requiring more than 16 oz of cement must be filled from a single mixture of cement and water Do not p...

Страница 15: ...ems Connect the black wire AC Hot to terminal strip J1 3 on the CPU board located in the bottom of the enclosure shown below Figure 2 3 J1 Location on CPU Board Connect the neutral wire white to termi...

Страница 16: ...lectrical way that data is transmitted The EL232 XPCD can read the data transmission strings sent by 12 of the more popular scale indicator families as shown in Table 3 1 It cannot read data from indi...

Страница 17: ...oop or RS232 using S3 10000100 1200 to 9600 See Figure 3 4 Generic smart receiver N A RS232 or current loop 1200 to 9600 Can receive serial data in a wide variety of intuitive formats Use when all els...

Страница 18: ...e connects the ground planes of the sending and receiving instruments RS232 should never be run more than 50 feet It may work but it may not work well or all the time Long RS232 data cables can act as...

Страница 19: ...current loop means that the instrument which sends the data also supplies the voltage to power the loop This voltage can be as small as 5 VDC to as much as 24 VDC When the loop goes through an optoco...

Страница 20: ...n external power supply or receiver This voltage can be a small as 5 VDC to as much as 24 VDC When the loop goes through an optocoupler a drop occurs This drop is about 2 VDC A current loop can power...

Страница 21: ...able indicators The power must be off when these values are changed If the power is on press the Reset switch on the CPU board to enter the new values see Figure 3 9 Figure 3 9 Reset Switch Location J...

Страница 22: ...transmitting to cannot properly receive the data change the 4N33 to a 4N25 opto isolators and the problem will normally disappear Figure 3 10 illustrates how to connect the current loop output of the...

Страница 23: ...ng The EL232 XPCD next shows the current baud rate setting it had read from switch SW1 The display shows bAUd12 for 1200 baud bAUd24 for 2400 baud bAUd48 for 4800 baud or bAUd96 for 9600 baud 4 4 Inpu...

Страница 24: ...SW1 07 is open the last value received is displayed continuously If this switch is closed the display again shows until readable data is again received This can be used to alert the operator that dat...

Страница 25: ...indicator incompatability mis wiring and mis programming both in the indicator and in the EL232 XPCD setup Double check the output of the meter and make sure something is being transmitted Use an osc...

Страница 26: ...ately 25 lb 11 3 kg Baud Rate 1200 2400 4800 and 9600 Interfaces 20 mA and RS232 standard The EL232 XPCD can communicate as shipped with twelve of the most common scale indicator families currently av...

Страница 27: ...accident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged non conformities Such equipment has not been modified altered...

Страница 28: ......

Страница 29: ......

Страница 30: ...230 W Coleman St Rice Lake WI 54868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 www ricelake com mobile m ricelake com 2011 Rice Lake Weighing Systems PN 16942 06 11...

Отзывы: